UHPSFC Dotaz Zobrazit nápovědu
This new analytical approach for high-throughput and comprehensive lipidomic analysis of biological samples using ultrahigh-performance supercritical fluid chromatography (UHPSFC) with electrospray ionization-mass spectrometry (ESI-MS) is based on lipid class separation using 1.7 μm particle bridged ethylene hybrid silica columns and a gradient of methanol-water-ammonium acetate mixture as a modifier. The method enables a fast separation of 30 nonpolar and polar lipid classes within 6-min analysis time covering six main lipid categories including fatty acyls, glycerolipids, glycerophospholipids, sphingolipids, sterols, and prenols. Individual lipid species within lipid classes are identified based on positive- and negative-ion full scan and tandem mass spectra measured with high mass accuracy and high resolving power. The method is used for the quantitative analysis of lipid species in biological tissues using internal standards for each lipid class. This high-throughput, comprehensive, and accurate UHPSFC/ESI-MS method is suitable for the lipidomic analysis of large sample sets in clinical research.
- MeSH
- glycerofosfolipidy analýza MeSH
- hmotnostní spektrometrie s elektrosprejovou ionizací metody MeSH
- lipidy analýza MeSH
- metabolomika metody MeSH
- pentanoly analýza MeSH
- sfingolipidy analýza MeSH
- steroly analýza MeSH
- superkritická fluidní chromatografie metody MeSH
- tandemová hmotnostní spektrometrie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Agomelatine is one of the newest antidepressants. Due to a different mechanism of action it offers a completely new approach in the treatment of depressive disorders. Two chromatographic methods for determination of agomelatine and its impurities were developed. The separations on UHPSFC system were accomplished using stationary phase based on BEH 2-EP and gradient elution with CO2 and methanol containing 20mM ammonium formate and 5% of water. The UHPLC separations were performed on stationary phase BEH Shield RP18. The mixture of acetonitrile and methanol in ratio 1:1 and ammonium acetate buffer pH 9.5 were used as mobile phase. Both developed methods were properly validated in terms of linearity, sensitivity (LOD, LOQ), accuracy and precision according to ICH guidelines. The UHPSFC method was linear in the range 0.25-70μg/ml for all analytes with method accuracy ≥97.4% and ≥100.2% and method intra-day precision RSD ≤2.4 and ≤0.8 for impurities and API (active pharmaceutical ingredient), respectively. The UHPLC method was linear in the range 0.1-10μg/ml for all analytes except three impurities for which the linear range was larger 0.1-25μg/ml. Method accuracy ≥95.7% and ≥95.2% and method intra-day precision RSD ≤2.6 and ≤1.5 were found for impurities and API, respectively. The measurement of tablet samples was performed and the selected parameters of the methods were compared. In conclusion, both methods were appropriate for the determination of agomelatine and its impurities in pharmaceutical quality control (QC), although the UHPSFC method was found as more convenient especially in the method development phase. The advantages of newly developed UHPSFC-PDA (photo diode array detector) method were its environmental friendliness due to the mobile phase used, a very good resolution, selectivity and high speed of analysis (total time of separation was 4.1min).
- Publikační typ
- abstrakt z konference MeSH
- Publikační typ
- abstrakt z konference MeSH
- Publikační typ
- abstrakt z konference MeSH
- Publikační typ
- abstrakt z konference MeSH
- Publikační typ
- abstrakt z konference MeSH
Ultrahigh-performance supercritical fluid chromatography-mass spectrometry (UHPSFC/MS) has a great potential for the high-throughput lipidomic quantitation of biological samples; therefore, the full optimization and method validation of UHPSFC/MS is compared here with ultrahigh-performance liquid chromatography-mass spectrometry (UHPLC/MS) in hydrophilic interaction liquid chromatography (HILIC) mode as the second powerful technique for the lipid class separation. First, the performance of six common extraction protocols is investigated, where the Folch procedure yields the best results with regard to recovery rate, matrix effect, and precision. Then, the full optimization and analytical validation for eight lipid classes using UHPSFC/MS and HILIC-UHPLC/MS methods are performed for the same sample set and applied for the lipidomic characterization of pooled samples of human plasma, human serum, and NIST SRM 1950 human plasma. The choice of appropriate internal standards (IS) for individual lipid classes has a key importance for reliable quantitative workflows illustrated by the selectivity while validation and the calculation of the quantitation error using multiple internal standards per lipid class. Validation results confirm the applicability of both methods, but UHPSFC/MS provides some distinct advantages, such as the successful separation of both non-polar and polar lipid classes unlike to HILIC-UHPLC/MS, shorter total run times (8 vs. 10.5 min), and slightly higher robustness. Various types of correlations between methods (UHPSFC/MS and HILIC-UHPLC/MS), biological material (plasma and serum), IS (laboratory and commercially mixtures), and literature data on the standard reference material show the intra- and inter-laboratory comparison in the quantitation of lipid species from eight lipid classes, the concentration differences in serum and plasma as well as the applicability of non-commercially available internal standard mixtures for lipid quantitation.
- MeSH
- hmotnostní spektrometrie metody MeSH
- krevní plazma chemie MeSH
- lidé MeSH
- lipidomika metody MeSH
- lipidy krev chemie MeSH
- sérum chemie MeSH
- superkritická fluidní chromatografie metody MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- validační studie MeSH
The potential of ultrahigh-performance liquid chromatography-mass spectrometry (UHPLC/MS) and ultrahigh-performance supercritical fluid chromatography (UHPSFC) coupled to negative-ion electrospray ionization mass spectrometry (ESI-MS) for the analysis of 46 oxylipins and 2 fatty acid standards is compared in terms of their chromatographic resolution with the emphasis on distinguishing isobaric interferences and the method sensitivity. UHPLC provides the baseline separation of 24 isobaric oxylipins within 13min, while UHPSFC enables the separation of only 20 isobaric oxylipins within 8min. Moreover, the UHPLC/ESI-MS method provides an average improvement of sensitivity by 3.5-fold. A similar trend is observed in the analysis of human plasma samples, but lower ion suppression effects caused by lysophospholipids (LPL) are observed in case of UHPSFC/ESI-MS due to better separation of LPL. Both methods are fully applicable for the analysis of oxylipins, but UHPLC/ESI-MS method is preferred due to better separation and higher sensitivity, which results in the identification of 31 oxylipins in human plasma based on available standards and additional tentative 20 identifications based on accurate m/z values and the fragmentation behavior known from the literature.
- MeSH
- hmotnostní spektrometrie s elektrosprejovou ionizací metody MeSH
- lidé MeSH
- oxylipiny krev chemie MeSH
- rozpouštědla chemie MeSH
- superkritická fluidní chromatografie metody MeSH
- teplota MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Reliable methods enabling detection of metal ions, and especially heavy metals, in different matrices are necessary in various fields such as ecology, pharmaceuticals and toxicology. As some of the currently used methods suffer from spectral and chemical interferences, this study investigates the applicability of SFC-MS/MS for the determination of metal ions. RESULTS: Effective novel approaches for metal ion analysis using CO2-based mobile phase were developed using three ligands forming metal complexes. As metal-EDTA complexes are prepared by simple addition of EDTA to the solution containing metal ions, this approach to metal ion analysis does not require laborious synthesis and isolation of solid metal-complexes. Besides, two other approaches using diethyldithiocarbamate and acetylacetonate as ligands were compared. Metal complexes of Cu, Co, Cr, Fe, Al, Mn, and Zn with all 3 ligands were synthesized and their identity was confirmed by high-resolution mass spectrometry (HRMS). The suitability of the three developed UHPSFC-MS/MS methods was examined using the determination of calibration range and repeatability of injections. Moreover, the universality of the developed UHPSFC-MS/MS method for the determination of metal-EDTA complexes was proved by analyzing Ni, Bi and Pb as additional metal ions. SIGNIFICANCE AND NOVELTY: This study demonstrates the extended range of applicability for SFC based separations. For the first time, the possibility to analyze metal complexes with EDTA using a fast and reliable ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) method is reported. The three developed UHPSFC-MS/MS methods are able to separate DDC, acac, and EDTA complexes of various metals very efficiently (total cycle times of 5, 2, and 3 min, respectively). They offer a fast and green alternative to chromatographic methods commonly used for metal ion analysis.
- Publikační typ
- časopisecké články MeSH