Functional and morphological examination of the lungs was performed in rats 48 hours after intratracheal injection of 0.5 mg/kg of the herbicide paraquat. Pronounced tachypnoea was observed (235+/-20 c/min), which also persisted under urethane anaesthesia (210+/-18 c/min). In control rats the mean breathing rate was 115+/-11 and 90+/-9 c/min in wake and anaesthetized rats respectively. The rate of breathing decreased to comparable values in experimental and control rats after bilateral cervical vagotomy. The functional residual lung capacity was significantly increased in experimental rats. After vagotomy also this increase of functional residual capacity became normalized. Histologically the disease was characterized by focal formation of hyaline membranes and oedema with occasional haemorrhages and signs of inflammation. The significant role fo vagal function in lung pathology is demonstrated.
- MeSH
- dýchání MeSH
- krysa rodu Rattus MeSH
- otrava patofyziologie MeSH
- paraquat otrava MeSH
- plíce patofyziologie MeSH
- plicní fibróza chemicky indukované patofyziologie MeSH
- respirační funkční testy MeSH
- tělesná hmotnost MeSH
- zvířata MeSH
- Check Tag
- krysa rodu Rattus MeSH
- mužské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- paraquat MeSH
BACKGROUND: Breath detection, i.e. its precise delineation in time is a crucial step in lung function data analysis as obtaining any clinically relevant index is based on the proper localization of breath ends. Current threshold or smoothing algorithms suffer from severe inaccuracy in cases of suboptimal data quality. Especially in infants, the precise analysis is of utmost importance. The key objective of our work is to design an algorithm for accurate breath detection in severely distorted data. METHODS: Flow and gas concentration data from multiple breath washout test were the input information. Based on universal physiological characteristics of the respiratory tract we designed an algorithm for breath detection. Its accuracy was tested on severely distorted data from 19 patients with different types of breathing disorders. Its performance was compared to the performance of currently used algorithms and to the breath counts estimated by human experts. RESULTS: The novel algorithm outperformed the threshold algorithms with respect to their accuracy and had similar performance to human experts. It proved to be a highly robust and efficient approach in severely distorted data. This was demonstrated on patients with different pulmonary disorders. CONCLUSION: Our newly proposed algorithm is highly robust and universal. It works accurately even on severely distorted data, where the other tested algorithms failed. It does not require any pre-set thresholds or other patient-specific inputs. Consequently, it may be used with a broad spectrum of patients. It has the potential to replace current approaches to the breath detection in pulmonary function diagnostics.
- Klíčová slova
- Automated breath detection, Breath end, Lung function testing, Medical algorithm design, Multiple breath washout test, Tidal breathing,
- MeSH
- algoritmy * MeSH
- diagnóza počítačová metody MeSH
- dítě MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- počítačové zpracování signálu * MeSH
- předškolní dítě MeSH
- respirační funkční testy MeSH
- Check Tag
- dítě MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- předškolní dítě MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
AIMS: The aim of the study was to analyze lung growth and abnormality of infant pulmonary function tests (IPFT) in congenital diaphragmatic hernia (CDH) survivors younger than three years of age with respect to unfavorable prognostic factors. METHODS: Thirty high-risk CDH survivors at the age of 1.32±0.54 years, body weight 9.76±1.25 kg were examined using IPFT: tidal breathing analysis, baby resistance/compliance, whole baby body plethysmography and rapid thoraco-abdominal compression. Gore-Tex patch was used in 13% of patients (GORE group). Pulmonary hypertension was diagnosed and managed in 13% (iNO group). Standard protocols and appropriate reference values were used and obtained data were statistically analysed. RESULTS: High incidence of peripheral airway obstruction (70%), increased value of functional residual capacity (FRCp) 191.3±24.5 mL (126.5±36.9 % predicted; P < 0.0005), increased value of effective airway resistance (Reff) 1.71±0.93 kPa.L(-1).s (144.4±80.1 % predicted; P < 0.01) and decreased specific compliance of the respiratory system (Crs/kg) 14.1±2.3 mL.kPa.kg(-1) (i.e., 76.1±20.1 % predicted, P < 0.0005) was noted in infants with CDH in comparison with reference values. Increased value of FRCp was found in GORE group (165.7±51.9 versus 120.4±31.2, P < 0.02) and in iNO group (183.1±52.6 versus 117.8±25.7 mL; P < 0.0005). CONCLUSION: A high incidence of peripheral airway obstruction, an increased value of FRCp and decreased specific compliance of the respiratory system was noted in infants with CDH. Unfavorable prognostic factors (Gore-Tex patch, pulmonary hypertension) correlate with more severe alteration of pulmonary function in infants.
- Klíčová slova
- chronic lung morbidity, congenital diaphragmatic hernia, infant pulmonary function testing, lung dysfunction,
- MeSH
- kojenec MeSH
- lidé MeSH
- morbidita trendy MeSH
- plíce patofyziologie MeSH
- plicní hypertenze etiologie patofyziologie MeSH
- respirační funkční testy MeSH
- retrospektivní studie MeSH
- rizikové faktory MeSH
- vrozená brániční kýla komplikace epidemiologie patofyziologie MeSH
- Check Tag
- kojenec MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika epidemiologie MeSH
The main aim was to find out whether long-lasting stepwise exposure to extreme hypoxia affects left ventricular (LV) geometry and systolic function. Adult male rats were exposed to intermittent hypobaric hypoxia (8 h/day) with increasing altitude in steps of 1000 m every 3 weeks up to 8000 m. While the LV cavity diastolic diameter did not change over the whole range of hypoxia, the wall thickness increased significantly at the altitude of 8000 m. LV fractional shortening ranged between 48.1 % and 50.1 % and remained unaffected even at the most severe hypoxia. At the end of experiment, haematocrit reached 83 %, mean systemic arterial pressure 120 % and relative LV weight 154 % of normoxic values while RV systolic pressure and relative RV weight doubled. Myocyte hypertrophy and myocardial fibrosis were more pronounced in RV than in LV. In conclusion, LV systolic function was preserved after chronic stepwise exposure of rats to extreme intermittent hypoxia despite moderate concentric hypertrophy and myocardial remodelling.
- Klíčová slova
- Chronic hypoxia, Extreme altitude, Heart function, Myocardial remodelling,
- MeSH
- funkce levé komory srdeční fyziologie MeSH
- funkce pravé komory srdeční fyziologie MeSH
- hypoxie krev patofyziologie MeSH
- krysa rodu Rattus MeSH
- nadmořská výška * MeSH
- potkani Wistar MeSH
- remodelace komor fyziologie MeSH
- zvířata MeSH
- Check Tag
- krysa rodu Rattus MeSH
- mužské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The use of pulmonary function tests (PFTs) has been widely described in airway diseases like asthma and cystic fibrosis, but for children's interstitial lung disease (chILD), which encompasses a broad spectrum of pathologies, the usefulness of PFTs is still undetermined, despite widespread use in adult interstitial lung disease. A literature review was initiated by the COST/Enter chILD working group aiming to describe published studies, to identify gaps in knowledge and to propose future research goals in regard to spirometry, whole-body plethysmography, infant and pre-school PFTs, measurement of diffusing capacity, multiple breath washout and cardiopulmonary exercise tests in chILD. The search revealed a limited number of papers published in the past three decades, of which the majority were descriptive and did not report pulmonary function as the main outcome.PFTs may be useful in different stages of management of children with suspected or confirmed chILD, but the chILD spectrum is diverse and includes a heterogeneous patient group in all ages. Research studies in well-defined patient cohorts are needed to establish which PFT and outcomes are most relevant for diagnosis, evaluation of disease severity and course, and monitoring individual conditions both for improvement in clinical care and as end-points in future randomised controlled trials.
- MeSH
- dítě MeSH
- intersticiální plicní nemoci diagnóza patofyziologie MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- předškolní dítě MeSH
- respirační funkční testy * MeSH
- věkové faktory MeSH
- Check Tag
- dítě MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- předškolní dítě MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
Pulmonary function was measured in 35 patients (mean age 11.6 years) with simple complete transposition 4.4 years after intracardiac repair. A disturbance in the lung function (greater than 2 SD from the normal value) was found in 88% of the patients. A marked increase in static recoil pressure (P less than 0.001) was most frequent (in 66%). Static lung compliance was only 75.1% of the predicted values. Values of mean vital and total lung capacity were decreased (P less than 0.01 and 0.001). Residual volume, the ratios of functional residual versus total lung capacity and residual volume versus total capacity were all increased. The signs of decreased patency of the airways were found in only 4 patients. A negative correlation was detected between the indices of lung stiffness and the age of assessment of lung function. A positive correlation was found between the ratios between functional residual and total capacity and pulmonary blood flow. No other correlation between lung function data and pulmonary arterial pressure or flow was proved. Increased lung stiffness, restriction of lung volume and hyperinflation could influence unfavorably the long-term results in successfully treated patients with simple complete transposition.
- MeSH
- dítě MeSH
- dospělí MeSH
- hemodynamika MeSH
- lidé MeSH
- měření objemu plic MeSH
- mladiství MeSH
- plíce patofyziologie chirurgie MeSH
- pružnost MeSH
- respirační funkční testy MeSH
- transpozice velkých cév patofyziologie chirurgie MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- lidé MeSH
- mladiství MeSH
- Publikační typ
- časopisecké články MeSH
Lung function tests (i.e., spirometry, flow volume, and body plethysmography) were performed in 213 patients (age 6-21 years, mean 11.3 years) with hemodynamically significant congenital heart defects: atrial septal defect, ventricular septal defect (VSD), tetralogy of Fallot, aortic stenosis and coarctation of the aorta. We measured lung vital capacity, total lung capacity (TLC), residual volume (RV), the percentage ratio of the latter two measurements (%RV/TLC), maximal expiratory flow rates at 25% and 50% of vital capacity, and specific airway conductance. Pulmonary restriction dominated in patients with tetralogy of Fallot; pulmonary hyperinflation was more frequent in patients with VSD and coarctation of the aorta; and obstruction of the airways was observed most frequently in patients with tetralogy of Fallot. In conclusion, we found a range of pathologic lung function parameters in patients with hemodynamically significant congenital heart defects.
- MeSH
- dítě MeSH
- dospělí MeSH
- hemodynamika MeSH
- lidé MeSH
- mladiství MeSH
- plíce patofyziologie MeSH
- respirační funkční testy MeSH
- vrozené srdeční vady patofyziologie MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- lidé MeSH
- mladiství MeSH
- Publikační typ
- časopisecké články MeSH
Assessment of kidney function in oncology patients is a fundamental factor in profiling the survival risk, determining the appropriate dose of chemotherapeutic drugs, and defining a patient eligibility for clinical trials with novel agents. Both overestimation and underestimation of kidney function may affect the treatment efficacy and outcomes. Overestimation may lead to overdosing or inappropriate agent selection and the corresponding toxicity, whereas underestimation may be responsible for underdosing or inappropriate agent exclusion and subsequent treatment failure. This is of utmost importance in patients with cancer. Evaluation of kidney function is not only limited to the estimation of glomerular filtration rate or creatinine clearance. An accurate assessment of kidney function is advisable to reduce variability in decision making and ultimately the therapeutic outcomes of toxicity and clinical benefit. Therefore, additional studies are needed to investigate the validity of currently used formulas estimating kidney function in this population as well as their applicability to traditional chemotherapy, novel targeted therapies, and immunotherapies. Because of rapid discovery and development of new cancer agents, a reliable and comprehensive manner to screen for potential nephrotoxicity is critically important. As kidney function not only is limited to glomerular filtration rate changes but also involves tubular and even vascular dysfunction, urinalysis and kidney imaging studies should also be considered before therapeutic decisions are taken. However, several questions remain regarding these new technologies such as kidney-on-a-chip systems for the assessment of kidney function and injury, particularly in oncology, and it has yet to be implemented in clinical practice.
- Klíčová slova
- biomarkers, glomerular filtration rate, kidney function, oncology,
- MeSH
- hodnoty glomerulární filtrace MeSH
- kreatinin MeSH
- ledviny * MeSH
- lidé MeSH
- nádory * farmakoterapie MeSH
- vyšetření funkce ledvin MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
- Názvy látek
- kreatinin MeSH
AIMS: The study analysed post-acute COVID-19 symptoms and the pulmonary function test (PFT) results in patients surviving the native strain of the virus. METHODS: The study was prospective; the inclusion criteria were positive PCR test for SARS-CoV-2 and age 18-100. Exclusion criteria were active respiratory infection, known or suspicious pre-existing pulmonary disease, cardiac failure, recent or acute pulmonary embolism, anaemia, and neuromuscular diseases. The recruitment period was 1st March 2020 - 25th December 2020. The initial examination was performed 4-12 weeks after the disease onset. All subjects underwent physical examination, anamnesis, chest x-ray and PFT. RESULTS: The study involved 785 subjects (345 male) mean age 53.8 (SD 14.6). The disease severity groups were: mild (G1), moderate (G2) and severe/critical (G3). Anosmia was present in the acute disease phase in 45.2% of G1 patients, but only in 4.5% of G3 patients. Dyspnoea occurred frequently in more severe groups (40%, 51.8% and 63.7% for G1, G2 and G3 respectively), while cough and fatigue showed no relationship to disease severity. Females were more likely to experience persistent symptoms. PFT results were significantly decreased in more severe groups compared to the mild COVID-19 patients, diffusing capacity was 86.3%, 79% and 68% of predicted values in G1, G2 and G3 respectively. CONCLUSION: Anosmia during the acute phase was associated with mild disease, persisting dyspnoea was more frequent after more severe COVID-19. Females tended to have persisting symptoms in post-acute phase more frequently. PFT results showed decrease with disease severity.
- Klíčová slova
- COVID-19, clinical presentation, post-acute phase, pulmonary function tests,
- MeSH
- anosmie MeSH
- COVID-19 * komplikace diagnóza MeSH
- dospělí MeSH
- dyspnoe etiologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- prospektivní studie MeSH
- respirační funkční testy MeSH
- SARS-CoV-2 MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH