repeatability of measurement Dotaz Zobrazit nápovědu
AIM: The primary aim of this study is to evaluate the repeatability of noninvasive break-up time (NIBUT) measurement by keratograph when it is determined from one, two or three partial measurements, and to recommend a suitable methodology for practice. Another goal is to verify that repeated measurements do not affect the measured value. MATERIAL AND METHODS: Thirty-eight healthy volunteers (30 women and 8 men) aged between 19 and 50 years old were included in the study, in which only one eye of each volunteer was measured. The study was designed as a prospective one. Each subject adapted to the local conditions of the laboratory for 15 minutes and subsequently underwent two series of NIBUT measurements (test, retest) on an OCULUS 3 Keratograph. The minimum time interval between the two series was 10 minutes, in which each series contained three partial measurements approximately 3 three measurements in the given series. Repeatability was assessed by a Bland-Altman analysis and expressed as a repeatability coefficient. In every case, only the time of the first break-up of the tear film was monitored. RESULTS: The statistical analysis did not show statistically significant differences both between partial measurements of NIBUT in the individual series (p = 0.92, p = 0.81) and when comparing all six measurements (p = 0.95). The mean values of the partial measurements ranged from 13.6 s to 14.4 s. The repeatability coefficients were found to be 15.0 s, 12.1 s and 10.0 s for methodologies A, B and C, respectively. A supplementary analysis for 12 eyes with low NIBUT (< 10 s) showed statistically significantly better repeatability in this group, with coefficients of 7.0 s (methodology A), 6.0 s (B) and 4.6 s (C). CONCLUSION: Determination of NIBUT from three consecutive measurements (with a sufficient interval of ideally a few minutes) significantly improves repeatability. Such repeated NIBUT measurements do not have a significant effect on the measured value. The mentioned methodology for measuring NIBUT on a keratograph can be recommended for use in practice.
- Klíčová slova
- BUT, NIBUT, break-up time test, dry eye syndrome, repeatability of measurement, tear film,
- MeSH
- diagnostické techniky oftalmologické přístrojové vybavení MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- prospektivní studie MeSH
- reprodukovatelnost výsledků MeSH
- rohovka diagnostické zobrazování MeSH
- slzy * chemie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Standard measures of response such as Response Evaluation Criteria in Solid Tumors are ineffective for bone lesions, often making breast cancer patients that have bone-dominant metastases ineligible for clinical trials with potentially helpful therapies. In this study we prospectively evaluated the test-retest uptake variability of 2-deoxy-2-[18F]fluoro-D-glucose (18F-FDG) in a cohort of breast cancer patients with bone-dominant metastases to determine response criteria. The thresholds for 95% specificity of change versus no-change were then applied to a second cohort of breast cancer patients with bone-dominant metastases. METHODS: For this study, nine patients with 38 bone lesions were imaged with 18F-FDG in the same calibrated scanner twice within 14 days. Tumor uptake was quantified by the most commonly used PET parameter, the maximum tumor voxel normalized by dose and body weight (SUVmax) and also by the mean of a 1-cc maximal uptake volume normalized by dose and lean-body-mass (SULpeak). The asymmetric repeatability coefficients with confidence intervals for SUVmax and SULpeak were used to determine the limits of 18F-FDG uptake variability. A second cohort of 28 breast cancer patients with bone-dominant metastases that had 146 metastatic bone lesions was imaged with 18F-FDG before and after standard-of-care therapy for response assessment. RESULTS: The mean relative difference of SUVmax and SULpeak in 38 bone tumors of the first cohort were 4.3% and 6.7%. The upper and lower asymmetric limits of the repeatability coefficient were 19.4% and - 16.3% for SUVmax, and 21.2% and - 17.5% for SULpeak. 18F-FDG repeatability coefficient confidence intervals resulted in the following patient stratification using SULpeak for the second patient cohort: 11-progressive disease, 5-stable disease, 7-partial response, and 1-complete response with three inevaluable patients. The asymmetric repeatability coefficients response criteria for SULpeak changed the status of 3 patients compared to the standard Positron Emission Tomography Response Criteria in Solid Tumors of ± 30% SULpeak. CONCLUSION: In evaluating bone tumor response for breast cancer patients with bone-dominant metastases using 18F-FDG SUVmax, the repeatability coefficients from test-retest studies show that reductions of more than 17% and increases of more than 20% are unlikely to be due to measurement variability. Serial 18F-FDG imaging in clinical trials investigating bone lesions in these patients, such as the ECOG-ACRIN EA1183 trial, benefit from confidence limits that allow interpretation of response.
- Klíčová slova
- 18F-FDG PET, Bone metastases, Breast cancer, Repeatability, Test-retest,
- Publikační typ
- časopisecké články MeSH
Rapid identification of methicillin-resistant Staphylococcus aureus (MRSA) is essential for proper initial antibiotic therapy and timely set up of hygienic measures. Recently, detection of MRSA using MALDI-TOF mass spectrometer mediated by the peptide-phenol-soluble modulin (PSM-mec)-linked to the class A mec gene complex present in SCCmec cassettes types II, III, and VIII of MRSA strains, has been commercially available. We present here a multicentre study on MALDI-TOF MS detection of MRSA evincing a poor repeatability and reproducibility of the assay. The sensitivity of the assay varies between 50 and 90% in strains carrying psmMEC and psmδ genes encoding for PSM-mec and δ-toxin (a member of the PSM peptide family), respectively. No false positive results were found. The very major error calculation was 30% and the major error achieved 0%. Interlaboratory repeatability varies between 0 and 100%. No significant difference was observed with the use of different cultivation media. Our data showed a poor sensitivity of the method excluding it from the use in routine laboratory testing.
- Klíčová slova
- MALDI-TOF MS, MRSA, PSM,
- MeSH
- bakteriální toxiny genetika MeSH
- chybná diagnóza MeSH
- diagnostické techniky molekulární * MeSH
- diagnostické testy rutinní MeSH
- lidé MeSH
- methicilin rezistentní Staphylococcus aureus genetika izolace a purifikace MeSH
- reprodukovatelnost výsledků MeSH
- senzitivita a specificita MeSH
- spektrometrie hmotnostní - ionizace laserem za účasti matrice * MeSH
- stafylokokové infekce diagnóza mikrobiologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- Názvy látek
- bakteriální toxiny MeSH
- staphylococcal delta toxin MeSH Prohlížeč
Hand-transmitted vibration has been observed to cause a wide variety of different signs and symptoms of neurological dysfunction. Different tests of tactile sensitivity, encompassing sensations of pressure, vibration, pain and temperature have been employed in the quantification of the sensorineural effects of vibration. However, since the results of such tests are dependent on different variables, and different versions of each test are used in different laboratories, the results are rarely reported in a manner allowing a direct comparison of results between studies. This paper reports on an investigation of the repeatability of thermotactile thresholds, as used in the detection of some neurological effects of hand-transmitted vibration. In the test, the temperature of a surface increased or decreased from a fixed reference (i.e. starting) temperature at a rate of 1 degree C per second. In a group of 10 health male subjects, five measures of both warm and cool thermal thresholds were obtained with each of 5 different starting temperatures on each of 3 different days. The 'neutral zone' between the warm and cool thresholds was also calculated. The starting temperature was found to have a significant effect on warm and cool thresholds, and less effect on the width of the neutral zone. It is concluded that the starting temperature should be controlled when determining thermotactile thresholds.
- MeSH
- analýza rozptylu MeSH
- dospělí MeSH
- lidé MeSH
- multivariační analýza MeSH
- nízká teplota MeSH
- prsty ruky fyziologie MeSH
- reprodukovatelnost výsledků MeSH
- teplota kůže * MeSH
- vibrace * MeSH
- vnímání teploty * MeSH
- vysoká teplota MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
- randomizované kontrolované studie MeSH
The soil redox potential (Eh) can provide essential information to characterise soil conditions. In practice, however, numerous problems may arise regarding: (i) Eh determination in soils, especially aerobic soils, e.g. variations in the instrumentation and methodology for Eh measurement, high spatial and temporal Eh variability in soils, irreversibility of the redox reaction at the surface electrode, chemical disequilibrium; and (ii) measurement interpretation. This study aimed at developing a standardised method for redox potential measurement in soils, in order to use Eh as a soil quality indicator. This paper presents practical improvements in soil Eh measurement, especially regarding the control of electromagnetic perturbations, electrode choice and preparation, soil sample preparation (drying procedure) and soil:water extraction rate. The repeatability and reproducibility of the measurement method developed are highlighted. The use of Eh corrected at pH7, pe+pH or rH2, which are equivalent notions, is proposed to facilitate interpretation of the results. The application of this Eh measurement method allows characterisation of soil conditions with sufficient repeatability, reproducibility and accuracy to demonstrate that conservation agriculture systems positively alter the protonic and electronic balance of soil as compared to conventional systems.
- Klíčová slova
- Accuracy, Indicator, Method, Redox potential, Repeatability, Reproducibility,
- MeSH
- koncentrace vodíkových iontů MeSH
- oxidace-redukce MeSH
- půda chemie MeSH
- zemědělské plodiny * MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
- Názvy látek
- půda MeSH
PURPOSE: To assess the intraday repeatability of macular architecture measurements in glaucomatous and non-glaucomatous patients using spectral-domain optical coherence tomography (SD-OCT) and to evaluate the independence from intraindividual intraocular pressure (IOP) fluctuations. METHODS: In this single-center, time-point comparison study, 88 eyes with glaucoma, 53 eyes with ocular hypertension (OHT), and 253 healthy eyes underwent two standardized SD-OCT and intraocular pressure (IOP) measurements on the same day with a 5-h time gap. Bland-Altman plots, intraclass correlation coefficients (ICC), and random-effects model were used to analyze repeatability of entire retinal thickness, retinal nerve fiber layer, ganglion cell layer, inner plexiform layer, and inner nuclear layer measurements. RESULTS: Intraday measurements were highly reproducible in all 3 groups. ICC were greater than 0.90, respectively. The pairwise comparisons of morphometric parameters showed a statistically significant difference (P < 0.001, respectively) between groups (glaucoma vs. control, glaucoma vs. OHT) and a significant influence of time points. No correlation was found between IOP fluctuations and morphometric parameters (P > 0.05, respectively), except for a weak positive correlation with GCL (rho = 0.109, P = 0.031). CONCLUSIONS: The evaluation of macular morphometric parameters of SD-OCT showed a high intraday repeatability and an excellent degree of agreement in glaucoma, ocular hypertension, and healthy groups. The fixed effects of time points were statistically significant. Except for a weak positive correlation of ganglion cell layer, variability did not appear to be affected by intraday IOP changes. Additional research is required to fully understand the impact of IOP fluctuations on macular morphometric parameters, considering the small observed IOP changes.
- Klíčová slova
- Glaucoma progression analysis, Posterior pole analysis, Spectral-domain optical coherence tomography,
- MeSH
- dospělí MeSH
- glaukom * diagnóza patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- macula lutea * patologie diagnostické zobrazování MeSH
- následné studie MeSH
- nervová vlákna * patologie MeSH
- nitrooční tlak * fyziologie MeSH
- oční hypertenze diagnóza patofyziologie MeSH
- optická koherentní tomografie * metody MeSH
- reprodukovatelnost výsledků MeSH
- retinální gangliové buňky * patologie MeSH
- senioři MeSH
- tonometrie oční MeSH
- zraková pole fyziologie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
OBJECTIVES: To describe the short- and medium-term repeatability of lung clearance index at 2.5% (LCI2.5 ) in infants and calculate the number of patients needed to enroll in a study (N) using LCI2.5 as a primary outcome. METHODS: An 8-month follow-up observational study was employed for assessing short-term [coefficient of repeatability (CR) and intraclass correlation (ICC)] and medium-term repeatability (Bland-Altman method) of LCI2.5 in infants with cystic fibrosis (CF) or recurrent wheeze (RW) measured by the nitrogen multiple-breath washout test (N2 -MBW). Using these variability data, the N to reach 90% test power at the level of statistical significance (0.05) was calculated. RESULTS: Forty infants with CF and 21 with RW were enrolled. Initial N2 -MBW testing was successful in 33 and 17 patients, respectively. Follow-up data were available for 23 and 11 infants, respectively. Short-term repeatability of LCI2.5 was high (CR = 1.10 and 1.04 in CF and RW patients, respectively; ICC = 0.88 and 0.83 in CF and RW patients, respectively). The between-subject standard deviation was <13% of the actual LCI2.5 value. In clinically stable patients, LCI2.5 did not significantly change during the 8-month follow-up. Mean LCI2.5 change was -0.08 (1% of baseline) in CF and -0.05 (0.6%) in RW, with 95% limits of agreement being (-1.70; 1.53) in CF and (-1.51; 1.40) in RW patients. N = 23 infants if both intragroup differences of LCI2.5 and minimal difference to be detected would be 2.0. CONCLUSION: N2 -MBW may be a reproducible tool with reasonable test power to detect differences in infant studies.
- Klíčová slova
- nitrogen multiple breath washout, sample size, variability,
- MeSH
- cystická fibróza * diagnóza MeSH
- dechové testy metody MeSH
- dusík MeSH
- kojenec MeSH
- lidé MeSH
- následné studie MeSH
- plíce MeSH
- respirační funkční testy metody MeSH
- Check Tag
- kojenec MeSH
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
- Názvy látek
- dusík MeSH
Quantum coherence represented by a superposition of energy eigenstates is, together with energy, an important resource for quantum technology and thermodynamics. Energy and quantum coherence however, can be complementary. The increase of energy can reduce quantum coherence and vice versa. Recently, it was realized that steady-state quantum coherence could be autonomously harnessed from a cold environment. We propose a conditional synthesis of N independent two-level systems (TLS) with partial quantum coherence obtained from an environment to one coherent system using a measurement able to increase both energy and coherence simultaneously. The measurement process acts here as a Maxwell demon synthesizing the coherent energy of individual TLS to one large coherent quantum battery. The measurement process described by POVM elements is diagonal in energy representation and, therefore, it does not project on states with quantum coherence at all. We discuss various strategies and their efficiency to reach large coherent energy of the battery. After numerical optimization and proof-of-principle tests, it opens way to feasible repeat-until-success synthesis of coherent quantum batteries from steady-state autonomous coherence.
- Publikační typ
- časopisecké články MeSH
- MeSH
- analýza rozptylu * MeSH
- čas * MeSH
- matematika MeSH
- metody MeSH
- Publikační typ
- časopisecké články MeSH
Predicting fish acute toxicity of chemicals in vitro is an attractive alternative method to the conventional approach using juvenile and adult fish. The rainbow trout (Oncorhynchus mykiss) cell line assay with RTgill-W1 cells has been designed for this purpose. It quantifies cell viability using fluorescent measurements for metabolic activity, cell- and lysosomal-membrane integrity on the same set of cells. Results from over 70 organic chemicals attest to the high predictive capacity of this test. We here report on the repeatability (intralaboratory variability) and reproducibility (interlaboratory variability) of the RTgill-W1 cell line assay in a round-robin study focusing on 6 test chemicals involving 6 laboratories from the industrial and academic sector. All participating laboratories were able to establish the assay according to preset quality criteria even though, apart from the lead laboratory, none had previously worked with the RTgill-W1 cell line. Concentration-response modeling, based on either nominal or geometric mean-derived measured concentrations, yielded effect concentrations (EC50) that spanned approximately 4 orders of magnitude over the chemical range, covering all fish acute toxicity categories. Coefficients of variation for intralaboratory and interlaboratory variability for the average of the 3 fluorescent cell viability measurements were 15.5% and 30.8%, respectively, which is comparable to other fish-derived, small-scale bioassays. This study therefore underlines the robustness of the RTgill-W1 cell line assay and its accurate performance when carried out by operators in different laboratory settings.
- Klíčová slova
- in vitro alternatives, round-robin study, validation,
- MeSH
- aniliny toxicita MeSH
- buněčné linie MeSH
- laboratoře MeSH
- Oncorhynchus mykiss MeSH
- reprodukovatelnost výsledků MeSH
- testy akutní toxicity metody MeSH
- viabilita buněk účinky léků MeSH
- vztah mezi dávkou a účinkem léčiva MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- 3,4-dichloroaniline MeSH Prohlížeč
- aniliny MeSH