Monitoring the ionic content of exhaled breath condensate in various respiratory diseases by capillary electrophoresis with contactless conductivity detection
M. Greguš, F. Foret, D. Kindlová, E. Pokojová, M. Plutinský, M. Doubková, Z. Merta, I. Binková, J. Skřičková, P. Kubáň,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- acetáty analýza metabolismus MeSH
- amoniové sloučeniny analýza metabolismus MeSH
- bronchiální astma metabolismus MeSH
- butyráty analýza metabolismus MeSH
- chloridy analýza metabolismus MeSH
- chronická obstrukční plicní nemoc metabolismus MeSH
- crown ethery MeSH
- cystická fibróza metabolismus MeSH
- dechové testy přístrojové vybavení metody MeSH
- dospělí MeSH
- draslík analýza metabolismus MeSH
- dusičnany analýza metabolismus MeSH
- dusitany analýza metabolismus MeSH
- elektroforéza kapilární MeSH
- hořčík analýza metabolismus MeSH
- ionty MeSH
- koncentrace vodíkových iontů MeSH
- kyselina mléčná analýza metabolismus MeSH
- lidé středního věku MeSH
- lidé MeSH
- plicní fibróza metabolismus MeSH
- plicní sarkoidóza metabolismus MeSH
- propionáty analýza metabolismus MeSH
- senioři MeSH
- sírany analýza metabolismus MeSH
- sodík analýza metabolismus MeSH
- vápník analýza metabolismus MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The analysis of an ionic profile of exhaled breath condensate (EBC) by capillary electrophoresis with contactless conductivity detection and double opposite end injection, is demonstrated. A miniature sampler made from a 2 ml syringe and an aluminium cooling cylinder was used for the fast collection of EBC (under one minute). Analysis of the collected EBC was performed in a 60 mM 2-(N-morpholino)ethanesulfonic acid, 60 mM L-histidine background electrolyte with 30 µM cetyltrimethylammonium bromide and 2 mM 18-crown-6 at pH 6, and excellent repeatability of migration times (RSD <1.3% (n = 7)) and peak areas (RSD < 7% (n = 7)) of 14 ions (inorganic anions, cations and organic acids) was obtained. It is demonstrated that the analysis of EBC samples obtained from patients with various respiratory diseases (chronic obstructive pulmonary disease, asthma, pulmonary fibrosis, sarcoidosis, cystic fibrosis) is possible in less than five minutes and the ionic profile can be compared with the group of healthy individuals. The analysis of the ionic profile of EBC samples provides a set of data in which statistically significant differences among the groups of patients could be observed for several clinically relevant anions (nitrite, nitrate, acetate, lactate). The developed collection system and method provides a highly reproducible and fast way of collecting and analyzing EBC, with future applicability in point-of-care diagnostics.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16000147
- 003
- CZ-PrNML
- 005
- 20160126093549.0
- 007
- ta
- 008
- 160108s2015 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1088/1752-7155/9/2/027107 $2 doi
- 035 __
- $a (PubMed)25944821
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Greguš, Michal $u Bioanalytical Instrumentation, CEITEC Masaryk University, Veveri 97, 602 00, Brno, Czech Republic. Department of Chemistry, Masaryk University, Kotlarska 2, 611 37 Brno, Czech Republic.
- 245 10
- $a Monitoring the ionic content of exhaled breath condensate in various respiratory diseases by capillary electrophoresis with contactless conductivity detection / $c M. Greguš, F. Foret, D. Kindlová, E. Pokojová, M. Plutinský, M. Doubková, Z. Merta, I. Binková, J. Skřičková, P. Kubáň,
- 520 9_
- $a The analysis of an ionic profile of exhaled breath condensate (EBC) by capillary electrophoresis with contactless conductivity detection and double opposite end injection, is demonstrated. A miniature sampler made from a 2 ml syringe and an aluminium cooling cylinder was used for the fast collection of EBC (under one minute). Analysis of the collected EBC was performed in a 60 mM 2-(N-morpholino)ethanesulfonic acid, 60 mM L-histidine background electrolyte with 30 µM cetyltrimethylammonium bromide and 2 mM 18-crown-6 at pH 6, and excellent repeatability of migration times (RSD <1.3% (n = 7)) and peak areas (RSD < 7% (n = 7)) of 14 ions (inorganic anions, cations and organic acids) was obtained. It is demonstrated that the analysis of EBC samples obtained from patients with various respiratory diseases (chronic obstructive pulmonary disease, asthma, pulmonary fibrosis, sarcoidosis, cystic fibrosis) is possible in less than five minutes and the ionic profile can be compared with the group of healthy individuals. The analysis of the ionic profile of EBC samples provides a set of data in which statistically significant differences among the groups of patients could be observed for several clinically relevant anions (nitrite, nitrate, acetate, lactate). The developed collection system and method provides a highly reproducible and fast way of collecting and analyzing EBC, with future applicability in point-of-care diagnostics.
- 650 _2
- $a acetáty $x analýza $x metabolismus $7 D000085
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a amoniové sloučeniny $x analýza $x metabolismus $7 D064751
- 650 _2
- $a bronchiální astma $x metabolismus $7 D001249
- 650 _2
- $a dechové testy $x přístrojové vybavení $x metody $7 D001944
- 650 _2
- $a butyráty $x analýza $x metabolismus $7 D002087
- 650 _2
- $a vápník $x analýza $x metabolismus $7 D002118
- 650 _2
- $a chloridy $x analýza $x metabolismus $7 D002712
- 650 _2
- $a crown ethery $7 D043844
- 650 _2
- $a cystická fibróza $x metabolismus $7 D003550
- 650 _2
- $a elektroforéza kapilární $7 D019075
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a koncentrace vodíkových iontů $7 D006863
- 650 _2
- $a ionty $7 D007477
- 650 _2
- $a kyselina mléčná $x analýza $x metabolismus $7 D019344
- 650 _2
- $a hořčík $x analýza $x metabolismus $7 D008274
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a dusičnany $x analýza $x metabolismus $7 D009566
- 650 _2
- $a dusitany $x analýza $x metabolismus $7 D009573
- 650 _2
- $a draslík $x analýza $x metabolismus $7 D011188
- 650 _2
- $a propionáty $x analýza $x metabolismus $7 D011422
- 650 _2
- $a chronická obstrukční plicní nemoc $x metabolismus $7 D029424
- 650 _2
- $a plicní fibróza $x metabolismus $7 D011658
- 650 _2
- $a plicní sarkoidóza $x metabolismus $7 D017565
- 650 _2
- $a sodík $x analýza $x metabolismus $7 D012964
- 650 _2
- $a sírany $x analýza $x metabolismus $7 D013431
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Foret, František
- 700 1_
- $a Kindlová, Dagmar
- 700 1_
- $a Pokojová, Eva
- 700 1_
- $a Plutinský, Marek
- 700 1_
- $a Doubková, Martina
- 700 1_
- $a Merta, Zdeněk
- 700 1_
- $a Binková, Ilona
- 700 1_
- $a Skřičková, Jana
- 700 1_
- $a Kubáň, Petr
- 773 0_
- $w MED00182181 $t Journal of breath research $x 1752-7163 $g Roč. 9, č. 2 (2015), s. 027107
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25944821 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160108 $b ABA008
- 991 __
- $a 20160126093712 $b ABA008
- 999 __
- $a ok $b bmc $g 1102428 $s 924353
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 9 $c 2 $d 027107 $e 20150506 $i 1752-7163 $m Journal of breath research $n J Breath Res $x MED00182181
- LZP __
- $a Pubmed-20160108