-
Something wrong with this record ?
Low-cost and prototype-friendly method for biocompatible encapsulation of implantable electronics with epoxy overmolding, hermetic feedthroughs and P3HT coating
M. Novák, J. Rosina, H. Bendová, K. Kejlová, A. Vlková, M. Rucki, L. Svobodová, R. Gürlich, J. Hajer
Language English Country England, Great Britain
Document type Journal Article, Research Support, Non-U.S. Gov't
NLK
Directory of Open Access Journals
from 2011
Free Medical Journals
from 2011
Nature Open Access
from 2011-12-01
PubMed Central
from 2011
Europe PubMed Central
from 2011
ProQuest Central
from 2011-01-01
Open Access Digital Library
from 2011-01-01
Open Access Digital Library
from 2011-01-01
Health & Medicine (ProQuest)
from 2011-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2011
Springer Nature OA/Free Journals
from 2011-12-01
- MeSH
- Electronics MeSH
- Epoxy Resins * MeSH
- Prostheses and Implants * MeSH
- Silicones MeSH
- Water MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
The research of novel implantable medical devices is one of the most attractive, yet complex areas in the biomedical field. The design and development of sufficiently small devices working in an in vivo environment is challenging but successful encapsulation of such devices is even more so. Industry-standard methods using glass and titanium are too expensive and tedious, and epoxy or silicone encapsulation is prone to water ingress with cable feedthroughs being the most frequent point of failure. This paper describes a universal and straightforward method for reliable encapsulation of circuit boards that achieves ISO10993 compliance. A two-part PVDF mold was machined using a conventional 3-axis machining center. Then, the circuit board with a hermetic feedthrough was placed in the mold and epoxy resin was injected into the mold under pressure to fill the cavity. Finally, the biocompatibility was further enhanced with an inert P3HT polymer coating which can be easily formulated into an ink. The biocompatibility of the encapsulants was assessed according to ISO10993. The endurance of the presented solution compared to silicone potting and epoxy potting was assessed by submersion in phosphate-buffered saline solution at 37 °C. The proposed method showed superior results to PDMS and simple epoxy potting.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc23004490
- 003
- CZ-PrNML
- 005
- 20230425141438.0
- 007
- ta
- 008
- 230418s2023 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1038/s41598-023-28699-6 $2 doi
- 035 __
- $a (PubMed)36717683
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Novák, Marek $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic. marek.novak@cvut.cz $u Department of Medical Biophysics and Medical Informatics, Third Faculty of Medicine, Charles University, Prague, Czech Republic. marek.novak@cvut.cz
- 245 10
- $a Low-cost and prototype-friendly method for biocompatible encapsulation of implantable electronics with epoxy overmolding, hermetic feedthroughs and P3HT coating / $c M. Novák, J. Rosina, H. Bendová, K. Kejlová, A. Vlková, M. Rucki, L. Svobodová, R. Gürlich, J. Hajer
- 520 9_
- $a The research of novel implantable medical devices is one of the most attractive, yet complex areas in the biomedical field. The design and development of sufficiently small devices working in an in vivo environment is challenging but successful encapsulation of such devices is even more so. Industry-standard methods using glass and titanium are too expensive and tedious, and epoxy or silicone encapsulation is prone to water ingress with cable feedthroughs being the most frequent point of failure. This paper describes a universal and straightforward method for reliable encapsulation of circuit boards that achieves ISO10993 compliance. A two-part PVDF mold was machined using a conventional 3-axis machining center. Then, the circuit board with a hermetic feedthrough was placed in the mold and epoxy resin was injected into the mold under pressure to fill the cavity. Finally, the biocompatibility was further enhanced with an inert P3HT polymer coating which can be easily formulated into an ink. The biocompatibility of the encapsulants was assessed according to ISO10993. The endurance of the presented solution compared to silicone potting and epoxy potting was assessed by submersion in phosphate-buffered saline solution at 37 °C. The proposed method showed superior results to PDMS and simple epoxy potting.
- 650 12
- $a epoxidové pryskyřice $7 D004853
- 650 12
- $a protézy a implantáty $7 D019736
- 650 _2
- $a elektronika $7 D004581
- 650 _2
- $a voda $7 D014867
- 650 _2
- $a silikony $7 D012828
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Rosina, Jozef $u Department of Medical Biophysics and Medical Informatics, Third Faculty of Medicine, Charles University, Prague, Czech Republic $u Department of Health Care and Population Protection, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic
- 700 1_
- $a Bendová, Hana $u Centre of Toxicology and Health Safety, National Institute of Public Health, Prague, Czech Republic
- 700 1_
- $a Kejlová, Kristina $u Centre of Toxicology and Health Safety, National Institute of Public Health, Prague, Czech Republic
- 700 1_
- $a Vlková, Alena $u Centre of Toxicology and Health Safety, National Institute of Public Health, Prague, Czech Republic
- 700 1_
- $a Rucki, Marian $u Centre of Toxicology and Health Safety, National Institute of Public Health, Prague, Czech Republic
- 700 1_
- $a Svobodová, Lada $u Centre of Toxicology and Health Safety, National Institute of Public Health, Prague, Czech Republic
- 700 1_
- $a Gürlich, Robert $u Department of General Surgery, Third Faculty of Medicine, Charles University, University Hospital Královské Vinohrady, Prague, Czech Republic
- 700 1_
- $a Hajer, Jan $u Department of Internal Medicine, Third Faculty of Medicine, Charles University, University Hospital Královské Vinohrady, Prague, Czech Republic. jan.hajer@fnkv.cz
- 773 0_
- $w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 13, č. 1 (2023), s. 1644
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/36717683 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20230418 $b ABA008
- 991 __
- $a 20230425141434 $b ABA008
- 999 __
- $a ok $b bmc $g 1924911 $s 1190699
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2023 $b 13 $c 1 $d 1644 $e 20230130 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
- LZP __
- $a Pubmed-20230418