Correlation between magnetic resonance imaging and ultrasound measurements of eye muscle thickness in thyroid-associated orbitopathy
Language English Country Czech Republic Media print-electronic
Document type Comparative Study, Evaluation Study, Journal Article
PubMed
24510024
DOI
10.5507/bp.2014.001
Knihovny.cz E-resources
- Keywords
- extraocular muscles, magnetic resonance imaging, orbit, thyroid-associated orbitopathy, ultrasound,
- MeSH
- Adult MeSH
- Exophthalmos etiology MeSH
- Graves Ophthalmopathy diagnostic imaging MeSH
- Hypertrophy diagnostic imaging MeSH
- Middle Aged MeSH
- Humans MeSH
- Magnetic Resonance Imaging standards MeSH
- Adolescent MeSH
- Young Adult MeSH
- Oculomotor Muscles diagnostic imaging MeSH
- Orbit diagnostic imaging pathology MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Sensitivity and Specificity MeSH
- Ultrasonography standards MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Young Adult MeSH
- Male MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Evaluation Study MeSH
- Comparative Study MeSH
AIMS: To compare ultrasound (US) and magnetic resonance imaging (MRI) measurements of horizontal eye muscle thickness in patients with thyroid-associated orbitopathy (TAO) and to compare these measurements according to the phase of the disease, the severity of exophthalmos, and the experience of the investigator. METHODS: A total of 180 orbits of adult patients with TAO were investigated from May 2007 to December 2012. In addition to their general ophthalmic examination, all patients underwent ultrasonographic measurement of horizontal eye muscle thickness with the B-scan technique and MRI examination of the orbit. Correlations between values obtained by US and MRI were determined for different subgroups according to disease activity (active, inactive), exophthalmos values (Hertel < 18 mm; Hertel 18-22 mm; Hertel > 22 mm), and the time period of examination (2007-2009; 2010-2012). RESULTS: Positive moderate correlation between US and MRI values for the medial rectus muscle (MRM; r = 0.690) and for the lateral rectus muscle (LRM; r = 0.572) was found. Significantly higher correlation was found for the MRM (P < 0.0001) and the LRM (P = 0.0008) in the time period 2010-2012 than in that of 2007-2009. Increasing correlation was found for MRM with increasing values of exophthalmos but this increase was not statistically significant. In the active phase of the disease compared to the inactive phase, statistically significant increased correlation (P = 0.019) was found for the LRM. CONCLUSIONS: Ultrasonographic measurement of horizontal eye muscles thickness in TAO moderately correlates with values obtained using MRI. The accuracy of ultrasonographic measurements in particular increases with the experience of the investigator.