Impact of sheath size and hemostasis time on radial artery patency after transradial coronary angiography and intervention in Japanese and non-Japanese patients: A substudy from RAP and BEAT (Radial Artery Patency and Bleeding, Efficacy, Adverse evenT) randomized multicenter trial

. 2018 Nov 01 ; 92 (5) : 844-851. [epub] 20180216

Jazyk angličtina Země Spojené státy americké Médium print-electronic

Typ dokumentu srovnávací studie, časopisecké články, multicentrická studie, randomizované kontrolované studie

Perzistentní odkaz   https://www.medvik.cz/link/pmid29451949

BACKGROUND: During transradial (TR) access, it remains unclear whether differences in baseline patients characteristics and hemostasis care impact the rate of radial artery occlusion (RAO). We sought to compare the rate of RAO after TR access with the 6 French(Fr) Glidesheath Slender (GSS6Fr, Terumo, Japan) or a standard 5 Fr sheath in Japanese and non-Japanese patients. METHODS AND RESULTS: The Radial Artery Patency and Bleeding, Efficacy, Adverse evenT (RAP and BEAT) trial randomized 1,836 patients undergoing TR coronary angiography and/or interventions to receive the GSS6Fr or the standard 5 Fr Glidesheath (GS5Fr, Terumo, Japan). Out of this study population, 1,087 were Japanese patients and 751 non-Japanese patients. The overall incidence of RAO was significantly higher in Japanese patients (3.6% vs. 1.2%, P = 0.002). Use of GSS6Fr was associated with higher rates of RAO than GS5Fr in Japanese patients (5% vs. 2.2%, P = 0.02) and with similar RAO rates in non-Japanese patients (1.3 vs. 1.1%, P = 1). The mean hemostasis time was significantly longer in Japanese patients (378 ± 253 vs. 159 ± 136 min, P < 0.001) and more Japanese patients had a hemostasis time of more than 6 hr (16.2% vs. 4.9%, P < 0.0001). Longer hemostasis time was an independent predictor of RAO (OR per additional hour 1.070, 95% CI 1.008-1.136, P = 0.03). CONCLUSIONS: Use of GSS6Fr was associated with a higher rate of RAO than a standard 5 Fr sheath in Japanese patients but not in non-Japanese patients. Whether improvement in post-procedural care and reduced hemostasis time could impact the incidence of RAO in Japanese patients should be further assessed.

Komentář v

PubMed

Zobrazit více v PubMed

Mamas MA, Fraser DG, Ratib K, Fath‐Ordoubadi F, El‐Omar M, Nolan J, Neyses L. Minimising radial injury: Prevention is better than cure. EuroIntervention 2014;10:824–832. PubMed

Abdelaal E, Molin P, Plourde G, Machaalany J, Bataille Y, Brousseau‐Provencher C, Montminy S, Larose E, Roy L, Gleeton O, Barbeau G, Nguyen CM, Noël B, Costerousse O, Bertrand OF. Successive transradial access for coronary procedures: Experience of Quebec Heart‐Lung Institute. Am Heart J 2013;165:325–331. PubMed

Dahm JB, Vogelgesang D, Hummel A, Staudt A, Völzke H, Felix SB. A randomized trial of 5 vs. 6 French transradial percutaneous coronary interventions. Catheter Cardiovasc Interv 2002;57:172–176. PubMed

Uhlemann M, Möbius‐Winkler S, Mende M, Eitel I, Fuernau G, Sandri M, Adams V, Thiele H, Linke A, Schuler G, Gielen S. The Leipzig prospective vascular ultrasound registry in radial artery catheterization: Impact of sheath size on vascular complications. J Am Coll Cardiol Intv 2012;5:36–43. PubMed

Rashid M, Kwok CS, Pancholy S, Chugh S, Kedev SA, Bernat I, Ratib K, Large A, Fraser D, Nolan J, Mamas MA. Radial artery occlusion after transradial interventions: A systematic review and meta‐analysis. J Am Heart Assoc 2016;5:e002686 10.1161/JAHA.115.002686. PubMed DOI PMC

Yonetsu T, Kakuta T, Lee T, Takayama K, Kakita K, Iwamoto T, Kawaguchi N, Takahashi K, Yamamoto G, Iesaka Y, Fujiwara H, Isobe M. Assessment of acute injuries and chronic intimal thickening of the radial artery after transradial coronary intervention by optical coherence tomography. Eur Heart J 2010;31:1608–1615. PubMed

Aminian A, Dolatabadi D, Lefebvre P, Zimmerman R, Brunner P, Michalakis G, Lalmand J. Initial experience with the Glidesheath Slender for transradial coronary angiography and intervention: A feasibility study with prospective radial ultrasound follow‐up. Catheter Cardiovasc Interv 2014;84:436–442. PubMed

Aminian A, Saito S, Takahashi A, Bernat I, Jobe RL, Kajiya T, Gilchrist IC, Louvard Y, Kiemeneij F, Van Royen N, Yamazaki S, Matsukage T, Rao SV. Comparison of a new slender 6 Fr sheath with a standard 5 Fr sheath for transradial coronary angiography and intervention: RAP and BEAT (radial artery patency and bleeding, efficacy, adverse evenT), a randomised multicentre trial. EuroIntervention 2017;13:e549–e556. PubMed

Kotowycz MA, Johnston KW, Ivanov J, Asif N, Almoghairi AM, Choudhury A, Nagy CD, Sibbald M, Chan W, Seidelin PH, Barolet AW, Overgaard CB, Džavík V. Predictors of radial artery size in patients undergoing cardiac catheterization: Insights from the good radial artery size prediction (GRASP) study. Can J Cardiol 2014;30:211–216. PubMed

Saito S, Ikei H, Hosokawa G, Tanaka S. Influence of the ratio between radial artery inner diameter and sheath outer diameter on radial artery flow after transradial coronary intervention. Catheter Cardiovasc Interv 1999;46:173–178. PubMed

Horie K, Tada N, Isawa T, Matsumoto T, Taguri M, Kato S, Honda T, Ootomo T, Inoue N. A randomized comparison of incidence of radial artery occlusion and symptomatic radial artery spasm associated with elective transradial coronary intervention using 6.5‐Fr sheathless eaucath guiding catheter vs. 6.0‐Fr Glidesheath Slender. EuroIntervention 2017. 10.4244/EIJ-D-17-00239. [Epub ahead of print] PubMed DOI

Yoo BS, Yoon J, Ko JY, Kim JY, Lee SH, Hwang SO, Choe KH. Anatomical consideration of the radial artery for transradial coronary procedures: Arterial diameter, branching anomaly and vessel tortuosity. Int J Cardiol 2005;101:421–427. PubMed

Yan Z, Zhou Y, Zhao Y, Zhou Z, Yang S, Wang Z. Anatomical study of forearm arteries with ultrasound for percutaneous coronary procedures. Circ J 2010;74:686–692. PubMed

Shimada YJ, Nakra NC, Fox JT, Kanei Y. Relation of race (Asian, African‐American, European‐American, and Hispanic) to activated clotting time after weight‐adjusted bolus of heparin during percutaneous coronary intervention. Am J Cardiol 2010;105:629–632. PubMed

Pancholy SB, Patel TM. Effect of duration of hemostatic compression on radial artery occlusion after transradial access. Catheter Cardiovasc Interv 2012;79:78–81. PubMed

Edris A, Gordin J, Sallam T, Wachsner R, Meymandi S, Traina M. Facilitated patent haemostasis after transradial catheterisation to reduce radial artery occlusion. EuroIntervention 2015;11:765–771. PubMed PMC

Dangoisse V, Guédès A, Chenu P, Hanet C, Albert C, Robin V, Tavier L, Dury C, Piraux O, Domange J, Jourdan K, Bihin B, Schroeder E. Usefulness of a gentle and short hemostasis using the transradial band device after transradial access for percutaneous coronary angiography and interventions to reduce the radial artery occlusion rate (from the prospective and randomized CRASOC I, II, and III studies). Am J Cardiol 2017;120:374–379. PubMed

Chong AY, Lo T, George S, Ratib K, Mamas M, Nolan J. The effect of pre‐procedure sublingual nitroglycerin on radial artery diameter and Allen's test outcome: Relevance to transradial catheterization. Cardiovasc Revasc Med 2017. 10.1016/j.carrev.2017.07.016. PubMed DOI

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...