Pulsed Field Ablation of Paroxysmal Atrial Fibrillation: 1-Year Outcomes of IMPULSE, PEFCAT, and PEFCAT II
Jazyk angličtina Země Spojené státy americké Médium print-electronic
Typ dokumentu klinické zkoušky, časopisecké články, multicentrická studie, práce podpořená grantem
PubMed
33933412
DOI
10.1016/j.jacep.2021.02.014
PII: S2405-500X(21)00196-1
Knihovny.cz E-zdroje
- Klíčová slova
- atrial fibrillation, catheter ablation, electroporation, pulmonary vein isolation, pulsed field ablation,
- MeSH
- fibrilace síní * chirurgie MeSH
- katetrizační ablace * MeSH
- lidé MeSH
- recidiva MeSH
- studie proveditelnosti MeSH
- venae pulmonales * chirurgie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
OBJECTIVES: This study sought to determine whether durable pulmonary vein isolation (PVI) using pulsed field ablation (PFA) translates to freedom from atrial fibrillation recurrence without an increase in adverse events. BACKGROUND: PFA is a nonthermal ablative modality that, in preclinical studies, is able to preferentially ablate myocardial tissue with minimal effect on surrounding tissues. Herein, we present 1-year clinical outcomes of PFA. METHODS: In 3 multicenter studies (IMPULSE [A Safety and Feasibility Study of the IOWA Approach Endocardial Ablation System to Treat Atrial Fibrillation], PEFCAT [A Safety and Feasibility Study of the FARAPULSE Endocardial Ablation System to Treat Paroxysmal Atrial Fibrillation], and PEFCAT II [Expanded Safety and Feasibility Study of the FARAPULSE Endocardial Multi Ablation System to Treat Paroxysmal Atrial Fibrillation]), paroxysmal atrial fibrillation patients underwent PVI using a basket or flower PFA catheter. Invasive remapping was performed at ∼2 to 3 months, and reconnected PVs were reisolated with PFA or radiofrequency ablation. After a 90-day blanking period, arrhythmia recurrence was assessed over 1-year follow-up. RESULTS: In 121 patients, acute PVI was achieved in 100% of PVs with PFA alone. PV remapping, performed in 110 patients at 93.0 ± 30.1 days, demonstrated durable PVI in 84.8% of PVs (64.5% of patients), and 96.0% of PVs (84.1% of patients) treated with the optimized biphasic energy PFA waveform. Primary adverse events occurred in 2.5% of patients (2 pericardial effusions or tamponade, 1 hematoma); in addition, there was 1 transient ischemic attack. The 1-year Kaplan-Meier estimates for freedom from any atrial arrhythmia for the entire cohort and for the optimized biphasic energy PFA waveform cohort were 78.5 ± 3.8% and 84.5 ± 5.4%, respectively. CONCLUSIONS: PVI with a "single-shot" PFA catheter results in excellent PVI durability and acceptable safety with a low 1-year rate of atrial arrhythmia recurrence. These data mitigate concern that the nonthermal ablative mechanism of PFA might mask undiscovered compromises to clinical success. (IMPULSE: A Safety and Feasibility Study of the IOWA Approach Endocardial Ablation System to Treat Atrial Fibrillation, NCT03700385; A Safety and Feasibility Study of the FARAPULSE Endocardial Ablation System to Treat Paroxysmal Atrial Fibrillation, NCT03714178; PEFCAT II Expanded Safety and Feasibility Study of the FARAPULSE Endocardial Multi Ablation System to Treat Paroxysmal Atrial Fibrillation [PEFCAT II], NCT04170608).
Department of Cardiology Homolka Hospital Prague Czech Republic
Department of Cardiology University Clinical Hospital Split Split Croatia
Citace poskytuje Crossref.org
Repeat procedures after pulsed field ablation for atrial fibrillation: MANIFEST-REDO study
COOPERATIVE-PFA: A Three-Arm Randomized Controlled Trial
Pulmonary Vein Morphology in Patients Undergoing Catheter Ablation of Atrial Fibrillation
Catheter ablation for non-paroxysmal atrial fibrillation. A review
Coronary Artery Spasm During Pulsed Field vs Radiofrequency Catheter Ablation of the Mitral Isthmus
Clinical Outcomes by Sex After Pulsed Field Ablation of Atrial Fibrillation
ClinicalTrials.gov
NCT04170608