A direct analysis in real-time (DART) ion source coupled to a high-resolution orbitrap mass spectrometer was used for the quantitative analysis of isoflavones isolated from soybeans. For the isolation of genistein, daidzein, glycitein, and their respective acetyl, malonyl, and glucoside forms, an extraction employing 80% aqueous MeOH enhanced by sonication was used. As far as the total isoflavones (expressed as aglycones) were to be determined, an acid hydrolysis with 80% aqueous EtOH and refluxing had to be employed, while in the latter case a good agreement of the results with the data generated by the UHPLC-orbitrap MS method was achieved, in the case of the analysis of non-hydrolyzed extracts, some overestimation of the results as compared with those generated by UHPLC-orbitrap MS was observed. A careful investigation of this phenomenon showed that the free aglycones originated from the conjugated forms of isoflavones in the DART ion source, thus contributing significantly to the "free" genistein/daidzein/glycitein signals during the DART analysis. Good recoveries (95-102%) and repeatabilities (RSD: 7-15%) were obtained at the spiking levels of 0.5, 1, and 0.05 g/kg, for daidzein, genistein, and glycitein, respectively. The limits of detection estimated for the respective analytes were 5 mg/kg.
The present study documents development and validation of a novel approach for determination of 23 perfluorinated alkylated substances (PFASs) in food of animal origin represented by milk and fish. The list of target analytes comprises four classes of PFASs, both ionic and non-ionic: 11 perfluorocarboxylic acids (PFCAs), 4 perfluorosulphonic acids (PFSAs), 5 perfluorosulphonamides (FOSAs) and 3 perfluorophosphonic acids (PFPAs). Fast sample preparation procedure is based on an extraction of target analytes with acetonitrile (MeCN) and their transfer (supported by inorganic salts and acidification) into the organic phase. Removing of matrix co-extracts by a simple dispersive solid phase extraction (SPE) employing ENVI-Carb and C18 sorbents is followed by an efficient sample pre-concentration performed by acetonitrile evaporation and subsequent dilution of residue in a small volume of methanol (matrix equivalent in the final extracts was 16 and 8 g mL(-1), for milk and fish respectively). Using modern instrumentation consisting of ultra-high performance liquid chromatography (UHPLC) hyphenated with a tandem mass spectrometer (MS/MS), limits of quantification (LOQs) as low as 0.001-0.006 μg kg(-1) for milk and 0.002-0.013 μg kg(-1) for fish can be achieved. Under these conditions, a wide spectrum of PFASs, including minor representatives, can be determined which enables collecting data required for human exposure studies. The pilot study employing the new method for examination of milk and canned fish samples was realized. Whereas in majority of canned fish products a wide spectrum of PFCAs, perfluorooctanesulphonic acid (PFOS) and perfluoro-1-octanesulphonamide (PFOSA) was detected, only in a few milk samples very low concentrations (LOQ levels) of PFOS and perfluorooctansulphonic acid (PFDS) were found.
- MeSH
- fluorokarbony analýza MeSH
- kyseliny alkansulfonové analýza MeSH
- maso analýza MeSH
- mléčné výrobky analýza MeSH
- potraviny konzervované analýza MeSH
- reprodukovatelnost výsledků MeSH
- ryby MeSH
- rychlé screeningové testy metody MeSH
- senzitivita a specificita MeSH
- tandemová hmotnostní spektrometrie metody MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH