STUDY OBJECTIVES: Evaluation of apnea detection using a tracheal sound (TS) sensor during sleep in patients with obstructive sleep apnea. METHODS: Polysomnographic recordings of 32 patients (25 male, mean age 66.7 ± 15.3 years, and mean body mass index 30.1 ± 4.5 kg/m2) were analyzed to compare the detection of apneas by four different methods of airflow signals: oronasal thermal airflow sensor (thermistor), nasal pressure transducer (NP), respiratory inductance plethysmography (RIPsum) and TS. The four used signals were scored randomly and independently from each other according to American Academy of Sleep Medicine rules. Results of apnea detection using NP, RIPsum and TS signals were compared to those obtained by thermistor as a reference signal. RESULTS: The number of apneas detected by the thermistor was 4,167. The number of apneas detected using the NP was 5,416 (+29.97%), using the RIPsum was 2,959 (-29.71%) and using the TS was 5,019 (+20.45%). The kappa statistics (95% confidence interval) were 0.72 (0.71 to 0.74) for TS, 0.69 (0.67 to 0.70) for NP, and 0.57 (0.55 to 0.59) for RIPsum. The sensitivity/specificity (%) with respect to the thermistor were 99.23/69.27, 64.07/93.06 and 96.06/76.07 for the NP, RIPsum and TS respectively. CONCLUSIONS: With the sensor placed properly on the suprasternal notch, tracheal sounds could help detecting apneas that are underscored by the RIPsum and identify apneas that may be overscored by the NP sensor due to mouth breathing. In the absence of thermistor, TS sensors can be used for apnea detection. CLINICAL TRIAL REGISTRATION: Registry: German Clinical Trials Register (DRKS), Title: Using the tracheal sound probe of the polygraph CID102 to detect and differentiate obstructive, central, and mixed sleep apneas in patients with sleep disordered breathing, Identifier: DRKS00012795, URL: https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00012795.
- MeSH
- lidé středního věku MeSH
- lidé MeSH
- měniče tlakové * MeSH
- nos MeSH
- pletysmografie * MeSH
- plicní ventilace * MeSH
- polysomnografie metody MeSH
- respirační zvuky * MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- syndromy spánkové apnoe diagnóza MeSH
- trachea MeSH
- ústa MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
OBJECTIVES: To determine if recording of suprasternal pressure (SSP) can classify apneas and hypopneas as reliably as respiratory inductance plethysmography (RIP) belts and to compare the two methods to classification with esophageal pressure (Pes), the reference method for assessing respiratory effort. METHODS: In addition to polysomnographic recordings that included Pes, SSP was recorded. Recordings from 32 patients (25 males, mean age 66.7 ± 15.3 years, and mean BMI 30.1 ± 4.5 kg/m2) were used to compare the classification of detected apneas and hypopneas by three methods of respiratory effort evaluation (Pes, RIP belts, and SSP). Signals were analyzed randomly and independently from each other. All recordings were analyzed according to AASM guidelines. RESULTS: Using Pes as a reference for apnea characterization, the Cohen kappa (κ) was 0.93 for SSP and 0.87 for the RIP. The sensitivity/specificity of SSP was 97.0%/96.9% for obstructive, 93.9%/98.3% for central, and 94.9%/97.9% for mixed apneas. The sensitivity/specificity of the RIP was 97.4%/91.9% for obstructive, 87.5%/97.9% for central, and 85.6%/96.6% for mixed apneas. For hypopnea characterization using the Pes as a reference, κ was 0.92 for SSP and 0.86 for the RIP. The sensitivity/specificity of SSP was 99.7%/97.6% for obstructive and 97.6%/99.7% for central. The sensitivity/specificity of the RIP was 99.8%/81.1% for obstructive and 81.1%/99.8% for central. CONCLUSIONS: These results confirm the excellent agreement in the detection of respiratory effort between SSP, RIP belts, and Pes signals. Thus, we conclude that apnea and hypopnea characterization in adults with SSP is a reliable method.
- MeSH
- ezofágus patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- mechanika dýchání fyziologie MeSH
- obstrukční spánková apnoe klasifikace diagnóza patofyziologie MeSH
- pletysmografie metody MeSH
- polysomnografie metody MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- tlak MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
STUDY OBJECTIVES: In obstructive sleep apnea (OSA) esophageal pressure (Pes) is the gold standard for measurement of respiratory effort, and respiratory inductance plethysmography (RIP) is considered an accepted measurement technique. However, the use of RIP could lead to limited accuracy in certain cases and therefore suprasternal pressure (SSP) monitoring might improve the reliability of OSA diagnosis. We aimed to use SSP for the visual characterization of respiratory events in adults and compared results to those obtained by RIP from polysomnography (PSG). METHODS: In patients with OSA, a 1-night SSP recording using the PneaVoX sensor (Cidelec, Sainte-Gemmes-sur-Loire, France) was done. In parallel, PSG was performed according to American Academy of Sleep Medicine criteria. A subgroup of patients agreed to have Pes measurement in addition. Characterizations of apneas as obstructive, central, and mixed as well as hypopneas as central and obstructive were done by visual evaluation of SSP, RIP, and Pes in random order by two independent scores (S1 and S2). The sensitivity and specificity of characterization by SSP compared to RIP and to Pes were calculated. RESULTS: Synchronous recordings of SSP and PSG were analyzed from n = 34 patients with OSA (AHI 34.1 ± 24.2 events/h); 9 of them had synchronized Pes monitoring as well. Interscorer agreement for apnea characterization as obstructive, central, and mixed based on SSP, RIP, and Pes were found, with R2 values from 0.91-0.99. The sensitivity of SSP in apnea characterization with reference to RIP (S1/S2) was 91.5%/92.3% for obstructive, 82.7%/76.2% for central, and 87.4%/79.9% for mixed. The sensitivity of SSP in apnea characterization with reference to Pes was (S1/S2) 93.1%/92.1% for obstructive, 80.8%/81.6% for central, and 91.7%/90.8% for mixed. Hypopnea was only classified for the nine patients with Pes. CONCLUSIONS: This study demonstrated a good agreement in the detection of respiratory effort with the SSP signal using the PneaVoX sensor compared to the RIP belts signals as well as to the Pes signal. These findings were consistently found by two independent scorers. In summary, results suggest that SSP is a reliable signal for the classification of respiratory events and could be used as an additional tool for OSA characterization in clinical practice.
- MeSH
- lidé středního věku MeSH
- lidé MeSH
- mechanika dýchání * fyziologie MeSH
- monitorování fyziologických funkcí přístrojové vybavení metody MeSH
- obstrukční spánková apnoe patofyziologie MeSH
- pletysmografie metody MeSH
- polysomnografie MeSH
- senzitivita a specificita MeSH
- sternum MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH