BACKGROUND: The CONtrolled delivery For ImproveD outcomEs with cliNiCal Evidence registry was initiated to characterize the clinical safety and device performance from experienced transcatheter aortic valve implantation (TAVI) centers in Europe and Australia that use the Portico valve to treat patients with severe aortic stenosis. We herein report for the first time the valve performance at 30-day across all implanted valve sizes and the 1-year survival from this registry. METHODS: This was a prospective, multicenter, single-arm observational clinical investigation of patients clinically indicated for implantation of a Portico valve in experienced TAVI centers. Patients were treated with a commercially available valve (size 23, 25, 27, or 29 mm) using either the first-generation delivery system (DS) (n = 501) or the second-generation (FlexNav) DS (n = 500). Adverse events were adjudicated by an independent clinical events committee according to Valve Academic Research Consortium-2 criteria. Echocardiographic outcomes were assessed at 30 days by an independent core laboratory, and a survival check was performed at 1 year. RESULTS: We enrolled 1001 patients (82.0 years, 62.5% female, 63.7% New York Heart Association functional class III/IV at baseline) from 27 clinical sites in 8 countries across Europe and one site in Australia. Implantation of a single valve was successful in 97.5% of subjects. Valve hemodynamics at 30 days were substantially improved relative to baseline, with large aortic valve areas and low mean gradients across all implanted valve sizes (aortic valve areas were 1.7 ± 0.4, 1.7 ± 0.5, 1.8 ± 0.5, and 2.0 ± 0.5 cm2, and mean gradients were 7.0 ± 2.7, 7.5 ± 4.7, 7.3 ± 3.3, and 6.4 ± 3.3 mmHg for 23, 25, 27, and 29 mm valve sizes, respectively). Across all implanted valve sizes, most patients (77.1%) had no patient-prosthesis mismatch. Death from any cause within 1 year occurred in 13.7% of the patients in the first-generation DS group as compared with 11.0% in the second-generation DS group (p = 0.2). CONCLUSIONS: The Portico valve demonstrated excellent hemodynamic performance across all valve sizes in a large cohort of subjects implanted in experienced TAVI centers. One-year survival rates were favorable when using both the first-generation and second-generation (FlexNav) DSs in this high-risk cohort. CLINICALTRIALSGOV IDENTIFIER: NCT03752866.
- Publikační typ
- časopisecké články MeSH
A total of 1001 subjects (82.0 years, 62.5% female, 63.7% NYHA III/IV at baseline) with severe aortic stenosis at high surgical risk were enrolled in the prospective CONFIDENCE registry and treated with a PorticoTM transcatheter heart valve (THV) using either a first-generation delivery system (DS) or the FlexNavTM DS. The objective of this registry is to characterize the procedural safety and device performance of the PorticoTM THV at 30 days. The study collected 'standard-of-care' clinical and device performance data, with adverse events adjudicated by an independent clinical event committee according to the Valve Academic Research Consortium-2 criteria. The implantation of a single PorticoTM THV was successful in 97.5% of subjects. The 30-day all-cause mortality, cardiovascular mortality, and disabling stroke rates were 2.6%, 2.1%, and 1.8%, respectively. A new pacemaker was implanted in 19.0% of subjects at 30 days. At 30 days, the effective orifice area and mean gradient values were 1.82 cm2 and 7.1 mmHg, respectively. The 30-day rate of moderate paravalvular leak (PVL) was 2.1%, with no occurrence of severe PVL. The PorticoTM THV demonstrated improved hemodynamic performance and low rates of safety events at 30 days in a large cohort of subjects implanted with the PorticoTM THV with either the first-generation DS or FlexNavTM DS.
- Publikační typ
- časopisecké články MeSH
Best practices for transcatheter aortic valve implantation with CoreValve include patient screening and valve size selection using multislice computed tomography, adherence to manufacturer recommendations for oversizing, control of implant depth to 6 mm or less, and management of conduction disturbances according to international guidelines. The ADVANCE II study implemented these strategies and demonstrated their relation to clinical outcomes. From October 2011 to April 2013, 200 patients with severe aortic stenosis were enrolled, and 194 were implanted. All imaging and electrocardiographic data were analyzed by an independent core laboratory, and adverse events were adjudicated to valve academic research consortium-2 definitions. The mean age was 80.2 ± 6.7 years and the mean Society of Thoracic Surgeons Predicted Risk of Mortality was 7.2 ± 6.8% for the enrolled patients. At 6 months, all-cause mortality was 9.2%, stroke was 2.6%, and permanent pacemaker implantation was 19.2% for class I and II indications. In patients with implant depth ≤6 mm, both mortality and permanent pacemaker implantation were lower than in patients with depth >6 mm (2.5% vs 14.5%, p <0.01 and 18.1% vs 31.7%, p = 0.03, respectively). The rate of moderate and severe paravalvular leak was 9.8% at 7 days after transcatheter aortic valve implantation, decreasing to 4.3% at 6 months (p = 0.02). Valves were significantly more oversized in patients with mild or less paravalvular leak at day 7 compared with those with moderate or severe (15.8 ± 8.0% vs 11.8 ± 4.9%, p = 0.01). In conclusion, findings from the ADVANCE II study reinforce that adherence to best clinical practices improves patient outcomes.
- MeSH
- aortální stenóza diagnostické zobrazování chirurgie MeSH
- bioprotézy * MeSH
- lidé MeSH
- pooperační komplikace epidemiologie MeSH
- prospektivní studie MeSH
- senioři MeSH
- srdeční chlopně umělé * MeSH
- transkatetrální implantace aortální chlopně přístrojové vybavení MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
- Geografické názvy
- Evropa epidemiologie MeSH
OBJECTIVES: The aim of the CoreValve prospective, international, post-market ADVANCE-II study was to define the rates of conduction disturbances and permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement with the Medtronic CoreValve System (Minneapolis, Minnesota) using optimized implantation techniques and application of international guidelines on cardiac pacing. BACKGROUND: Conduction disturbances are a frequent complication of transcatheter aortic valve replacement. The rates of PPI in the published reports vary according to bioprosthesis type and the indications for PPI. METHODS: The primary endpoint was the 30-day incidence of PPI with Class I/II indications when the Medtronic CoreValve System was implanted at an optimal depth (≤6 mm below the aortic annulus). The timing and resolution of all new-onset conduction disturbances were analyzed. RESULTS: A total of 194 patients were treated. The overall rate of PPI for Class I/II indications was 18.2%. An optimal depth was reached in 43.2% of patients, with a nonsignificantly lower incidence of PPI in patients with depths ≤6 mm, compared with those with deeper implants (13.3% vs. 21.1%; p = 0.14). In a paired analysis, new-onset left bundle branch block and first-degree atrioventricular block occurred in 45.4% and 39.0% of patients, respectively, and resolved spontaneously within 30 days in 43.2% and 73.9%, respectively. In patients with new PPI, the rate of intrinsic sinus rhythm increased from 25.9% at 7 days to 59.3% at 30 days (p = 0.004). CONCLUSIONS: Optimal Medtronic CoreValve System deployment and adherence to international guidelines on cardiac pacing are associated with a lower rate of new PPI after transcatheter aortic valve replacement, compared with results reported in previous studies. (CoreValve Advance-II Study: Prospective International Post-Market Study [ADVANCE II]; NCT01624870).
- MeSH
- aortální chlopeň * patofyziologie MeSH
- aortální stenóza diagnóza mortalita patofyziologie terapie MeSH
- časové faktory MeSH
- chirurgická náhrada chlopně škodlivé účinky přístrojové vybavení metody mortalita MeSH
- dodržování směrnic * normy MeSH
- Kaplanův-Meierův odhad MeSH
- kardiostimulace umělá * škodlivé účinky mortalita normy MeSH
- lékařská praxe - způsoby provádění * normy MeSH
- lidé MeSH
- postmarketingový dozor MeSH
- prospektivní studie MeSH
- protézy - design MeSH
- rizikové faktory MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- směrnice pro lékařskou praxi jako téma * normy MeSH
- srdeční arytmie diagnóza etiologie mortalita patofyziologie terapie MeSH
- srdeční chlopně umělé * MeSH
- srdeční katetrizace škodlivé účinky přístrojové vybavení metody mortalita MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Evropa MeSH