BACKGROUND: Accurate assessment of carotid stenosis severity is important for proper patient management. The present study aimed to compare the evaluation of carotid stenosis severity using four duplex sonography (DUS) measurements, including peak systolic velocity (PSV), PSV ratio in stenosis and distal to stenosis (PSVICA/ICA ratio), end-diastolic velocity (EDV), and B-mode, with computed tomography angiography (CTA), and to evaluate the impact of plaque morphology on correlation between DUS and CTA. METHODS: Consecutive patients with carotid stenosis of ≥40% examined using DUS and CTA were included. Plaque morphology was also determined using magnetic resonance imaging. Spearman's correlation and Kendall's rank correlation were used to evaluate the results. RESULTS: A total of 143 cases of internal carotid artery stenosis of ≥40% based on DUS were analyzed. The PSVICA/ICA ratio showed the highest correlation [Spearman's correlation r = 0.576) with CTA, followed by PSV (r = 0.526), B-mode measurement (r = 0.482), and EDV (r = 0.441; p < 0.001 in all cases]. The worst correlation was found for PSV when the plaque was calcified (r = 0.238), whereas EDV showed a higher correlation (r = 0.523). Correlations of B-mode measurement were superior for plaques with smooth surface (r = 0.677), while the PSVICA/ICA ratio showed the highest correlation in stenoses with irregular (r = 0.373) or ulcerated (r = 0.382) surfaces, as well as lipid (r = 0.406), fibrous (r = 0.461), and mixed (r = 0.403; p < 0.01 in all cases) plaques. Nevertheless, differences between the mentioned correlations were not statistically significant (p > 0.05 in all cases). CONCLUSION: PSV, PSVICA/ICA ratio, EDV, and B-mode measurements showed comparable correlations with CTA in evaluation of carotid artery stenosis based on their correlation with CTA results. Heavy calcifications and plaque surface irregularity or ulceration negatively influenced the measurement accuracy.
- Publikační typ
- časopisecké články MeSH
- MeSH
- cerebrální infarkt diagnostické zobrazování etiologie MeSH
- cévní mozková příhoda * MeSH
- karotická endarterektomie * škodlivé účinky MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- rizikové faktory MeSH
- stenóza arteria carotis * diagnostické zobrazování chirurgie MeSH
- stenty MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND AND AIM: In-stent restenosis (ISR) belongs to an infrequent but potentially serious complication after carotid angioplasty and stenting in patients with severe carotid stenosis. Some of these patients might be contraindicated to repeat percutaneous transluminal angioplasty with or without stenting (rePTA/S). The purpose of the study is to compare the safety and effectiveness of carotid endarterectomy with stent removal (CEASR) and rePTA/S in patients with carotid ISR. METHODS: Consecutive patients with carotid ISR (≥80%) were randomly allocated to the CEASR or rePTA/S group. The incidence of restenosis after intervention, stroke, transient ischaemic attack myocardial infarction and death 30 days and 1 year after intervention and restenosis 1 year after intervention between patients in CEASR and rePTA/S groups were statistically evaluated. RESULTS: A total of 31 patients were included in the study; 14 patients (9 males; mean age 66.3±6.6 years) were allocated to CEASR and 17 patients (10 males; mean age 68.8±5.6 years) to the rePTA/S group. The implanted stent in carotid restenosis was successfully removed in all patients in the CEASR group. No clinical vascular event was recorded periproceduraly, 30 days and 1 year after intervention in both groups. Only one patient in the CEASR group had asymptomatic occlusion of the intervened carotid artery within 30 days and one patient died in the rePTA/S group within 1 year after intervention. Restenosis after intervention was significantly greater in the rePTA/S group (mean 20.9%) than in the CEASR group (mean 0%, p=0.04), but all stenoses were <50%. Incidence of 1-year restenosis that was ≥70% did not differ between the rePTA/S and CEASR groups (4 vs 1 patient; p=0.233). CONCLUSION: CEASR seems to be effective and save procedures for patients with carotid ISR and might be considered as a treatment option. TRIAL REGISTRATION NUMBER: NCT05390983.
- MeSH
- angioplastika MeSH
- arteriae carotides MeSH
- karotická endarterektomie * škodlivé účinky MeSH
- koronární restenóza * MeSH
- lidé středního věku MeSH
- lidé MeSH
- rizikové faktory MeSH
- senioři MeSH
- stenóza MeSH
- stenty MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH