BACKGROUND/AIMS: Upper gastrointestinal bleeding (UGIB) is the most common GI condition requiring hospitalization, and can be diagnosed by direct visualization. The present study aimed to evaluate the safety and feasibility of using the PillSense system (EnteraSense Ltd.), a novel diagnostic tool designed for the rapid in vivo detection of UGIB, in human volunteers. METHODS: In the present study, 10 volunteers swallowed a PillSense capsule, followed by 2 servings of an autologous blood preparation. Participants were monitored for capsule passage, overall tolerability of the procedure, and adverse events. RESULTS: The procedure was completed per the protocol established in the present study in 9/10 cases. In 9 of the subjects, after capsule ingestion, the device indicated the absence of blood with sensor output values of 1. After the ingestion of the first blood mixture, the sensor outputs of all devices increased from 2.8 to 4, indicating that each camera detected blood. The sensor output remained within that range after the ingestion of the second mixture; however, in one case, the baseline capsule signal was positive, because of a preexisting condition. The passage of the capsule was verified in all patients, and no adverse events were reported. CONCLUSION: The first trial of the PillSense system in human subjects demonstrated the feasibility, safety, and tolerability of utilizing this product as a novel, noninvasive, and easy-to-use triage tool for the diagnosis of patients suspected of having UGIB.
- Publikační typ
- časopisecké články MeSH
BACKGROUND AND AIMS: Most patients with type 2 diabetes mellitus have obesity. Studies show that bariatric surgery is superior to medical treatment for remission of type 2 diabetes mellitus. Nevertheless, very few patients undergo surgery, and a less-invasive endoscopic alternative is desirable. METHODS: This was a single-arm first-in-human pilot study designed to evaluate the technical feasibility, safety, and clinical performance of the incisionless magnetic anastomosis system (IMAS) to create a partial jejunal diversion (PJD). Ten patients with obesity and type 2 diabetes mellitus, prediabetes, or no diabetes were enrolled. A PJD to the ileum was attempted in all patients under general anesthesia. The IMAS was delivered through the working channel of a colonoscope, with laparoscopic supervision. The patients were not required to participate in an intensive lifestyle/diet management program. Endoscopic visualization of the anastomosis was obtained at 2, 6, and 12 months. Patient weight, glycemic profile, and metabolic panels were acquired at 0.5, 1, 2, 3, 6, 9, and 12 months. RESULTS: A PJD was created in all patients with no device-related serious adverse events. The anastomosis remained widely patent in all patients at 1 year. Average total weight loss was 14.6% (40.2% excess weight loss at 12 months). A significant reduction in glycated hemoglobin level was observed in all diabetic (1.9%) and prediabetic (1.0%) patients, while reducing or eliminating the use of diabetes medications. CONCLUSIONS: Permanent anastomosis for PJD was created in all patients with the IMAS. This resulted in improvement in measures of hyperglycemia and progressive weight loss. (Clinical trial registration number: NCT02839512.).
- MeSH
- anastomóza chirurgická přístrojové vybavení metody MeSH
- bariatrická chirurgie metody MeSH
- diabetes mellitus 2. typu komplikace farmakoterapie metabolismus MeSH
- dospělí MeSH
- gastrointestinální endoskopie metody MeSH
- glykovaný hemoglobin metabolismus MeSH
- hypoglykemika terapeutické užití MeSH
- jejunum chirurgie MeSH
- krevní glukóza metabolismus MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnety * MeSH
- obezita komplikace metabolismus chirurgie MeSH
- pilotní projekty MeSH
- prediabetes komplikace metabolismus MeSH
- prospektivní studie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH