Matrix M protein combined with nucleocapsid N protein could be a promising combination of virus antigens for diagnosing the porcine reproductive and respiratory syndrome. The goal of this work was to express the recombinant M protein of the porcine reproductive and respiratory syndrome virus in Escherichia coli cells and compare its serological reactivity with the N protein of the virus. The gene coding for the M protein was cloned into the pDest17 vector. The resulting protein was purified by metalochelating affinity chromatography. Recombinant M protein was applied as an antigen in immunoblot test and compared on a panel of porcine sera with N protein based IDEXX test. Of 120 examined samples, the majority (78.3%) gave identical results using both compared tests. From the group of discrepant results, IDEXX test identified considerably more positive sera (17.5%) than M protein based test (4.2%). The main contribution of the work is finding that although IDEXX test proved to be more sensitive than M protein based test, 4.2% of sera would escape detection by serological test based on N protein. Further development and purification of the M protein for the use in Enzyme Linked Immunosorbent Assay format test could increase the performance of serological testing.
PURPOSE OF THE STUDY In developing new or modifying the existing surgical treatment methods of spine conditions an integral part of ex vivo experiments is the assessment of mechanical, kinematic and dynamic properties of created constructions. The aim of the study is to create an appropriately validated numerical model of canine cervical spine in order to obtain a tool for basic research to be applied in cervical spine surgeries. For this purpose, canine is a suitable model due to the occurrence of similar cervical spine conditions in some breeds of dogs and in humans. The obtained model can also be used in research and in clinical veterinary practice. MATERIAL AND METHODS In order to create a 3D spine model, the LightSpeed 16 (GE, Milwaukee, USA) multidetector computed tomography was used to scan the cervical spine of Doberman Pinscher. The data were transmitted to Mimics 12 software (Materialise HQ, Belgium), in which the individual vertebrae were segmented on CT scans by thresholding. The vertebral geometry was exported to Rhinoceros software (McNeel North America, USA) for modelling, and subsequently the specialised software Abaqus (Dassault Systemes, France) was used to analyse the response of the physiological spine model to external load by the finite element method (FEM). All the FEM based numerical simulations were considered as nonlinear contact statistic tasks. In FEM analyses, angles between individual spinal segments were monitored in dependence on ventroflexion/ /dorziflexion. The data were validated using the latero-lateral radiographs of cervical spine of large breed dogs with no evident clinical signs of cervical spine conditions. The radiographs within the cervical spine range of motion were taken at three different positions: in neutral position, in maximal ventroflexion and in maximal dorziflexion. On X-rays, vertebral inclination angles in monitored spine positions were measured and compared with the results obtain0ed from FEM analyses of the numerical model. RESULTS It is obvious from the results that the physiological spine model tested by the finite element method shows a very similar mechanical behaviour as the physiological canine spine. The biggest difference identified between the resulting values was reported in C6-C7 segment in dorsiflexion (Δφ = 5.95%), or in C4-C5 segment in ventroflexion (Δφ = -3.09%). CONCLUSIONS The comparisons between the mobility of cervical spine in ventroflexion/dorsiflexion on radiographs of the real models and the simulated numerical model by finite element method showed a high degree of results conformity with a minimal difference. Therefore, for future experiments the validated numerical model can be used as a tool of basic research on condition that the results of analyses carried out by finite element method will be affected only by an insignificant error. The computer model, on the other hand, is merely a simplified system and in comparison with the real situation cannot fully evaluate the dynamics of the action of forces in time, their variability, and also the individual effects of supportive skeletal tissues. Based on what has been said above, it is obvious that there is a need to exercise restraint in interpreting the obtained results. Key words: cervical spine, kinematics, numerical modelling, finite element method, canine.
- MeSH
- krční obratle diagnostické zobrazování fyziologie MeSH
- počítačová rentgenová tomografie MeSH
- počítačová simulace * MeSH
- psi MeSH
- rozsah kloubních pohybů * fyziologie MeSH
- zobrazování trojrozměrné MeSH
- zvířata MeSH
- Check Tag
- psi MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
The aim was to construct a composite structure for bone tissue substitute on the basis of a degradable composite of an organic nanofiber carrier and an inorganic matrix in 3D, and to achieve subsequent colonisation by differentiated human mesenchymal stem cells (hMSC) towards osteocytes. We developed an active bone tissue substitute using nanofiber technology for a polycaprolactone (PCL) scaffold with the addition of hydroxyapatite and the colonisation of both components with hMSC with the ability of differentiation towards osteocytes. The constructed composition included the components necessary for bone healing (inorganic and cellular) and it also forms a spatially-oriented 3D structure. We used polycaprolactone Mw 70,000 with electrostatic spinning for the formation of nanofibers using a modified NanospiderTM method. For the inorganic component we used orthophosphate-calcium silicate with a crystal size of 1-2 mm which the nanofiber membrane was coated with. Both components were connected together with a tissue adhesive based of fibrin glue. Cultivated hMSC cells at a concentration of 1.2 × 104/cm2 were multiplied in vitro and then cultivated in the expansion medium. HMSC overgrew both the PCL membrane and the Si-CaP crystals. After colonisation with cultivated cells, this composite 3D structure can serve as a three-dimensional bone tissue replacement.
- Klíčová slova
- polykaprolakton,
- MeSH
- hydroxyapatity MeSH
- kostní náhrady * chemie klasifikace MeSH
- lidé MeSH
- mezenchymální kmenové buňky MeSH
- nanovlákna MeSH
- techniky in vitro MeSH
- vstřebatelné implantáty MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- práce podpořená grantem MeSH
UNLABELLED: PURPOSE OF THE STUDY In a long-term perspective, it is better to remove implants after fracture healing. However, subsequent full or excessive loading of an extremity may result in refracture, and the bone with holes after screw removal may present a site with predilection for this. The aim of the study was to find ways of how to decrease risk factors for refracture in such a case. This involved support to the mechanical properties of a bone during its remodelling until defects following implant removal are repaired, using a material tolerated by bone tissue and easy to apply. It also included an assessment of the mechanical properties of a bone after filling the holes in it with a newly developed biodegradable polymer-composite gel ("bone paste"). The composite also has a prospect of being used to repair bony defects produced by pathological processes. MATERIAL AND METHODS Experiments were carried out on intact weight-bearing small bones in dogs. A total of 27 specimens of metacarpal/metatarsal bones were used for ex vivo testing. They were divided into three groups: K1 (n = 9) control undamaged bones; K2 (n = 9) control bones with iatrogenic damage simulating holes left after cortical screw removal; EXP (n = 9) experimental specimens in which simulated holes in bone were filled with the biodegradable self-hardening composite. The bone specimens were subjected to three-point bending in the caudocranial direction by a force acting parallel to the direction of drilling in their middiaphyses. The value of maximum load achieved (N) and the corresponding value of a vertical displacement (mm) were recorded in each specimen, then compared and statistically evaluated. RESULTS On application of a maximum load (N), all bone specimens broke in the mid-part of their diaphyses. In group K1 the average maximum force of 595.6 ± 79.5 N was needed to break the bone; in group K2 it was 347.6 ± 58.6 N; and in group EXP it was 458.3 ± 102.7 N. The groups with damaged bones, K2 and EXP, were compared and the difference was found to be statistically significant (p ≤ 0.05). CONCLUSIONS The recently developed biodegradable polymer-composite gel is easy and quick to apply to any defect, regardless of its shape, in bone tissue. The ex vivo mechanical tests on canine short bones showed that the composite applied to defects, which simulated holes left after screw removal, provided sufficient mechanical support to the bone architecture. The results of measuring maximum loading forces were statistically significant. However, before the composite could be recommended for use in veterinary or human medical practice, thorough pre-clinical studies will be required. KEY WORDS: fracture fixation, mechanical testing, bone plate, cortical screw, refracture.
- MeSH
- biokompatibilní materiály terapeutické užití MeSH
- biomechanika MeSH
- fraktury kostí chirurgie terapie MeSH
- metakarpální kosti zranění chirurgie MeSH
- metatarzální kosti zranění chirurgie MeSH
- odstranění implantátu * MeSH
- psi MeSH
- zvířata MeSH
- Check Tag
- psi MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
Equine insect bite hypersensitivity (IBH) is a seasonal IgE-mediated dermatosis caused by bites of insects of the genus Culicoides. A familial predisposition for the disease has been shown but, except for the MHC, the genes involved have not been identified so far. An immunogenomic analysis of IBH was performed in a model population of Old Kladruby horses, all living in the same environment. Clinical signs of IBH were used as phenotypic manifestation of IBH. Furthermore, total serum IgE levels were determined in the sera of these horses and used as an independent phenotypic marker for the immunogenetic analysis. Single nucleotide polymorphisms (SNPs) in candidate immunity-related genes were used for association analyses. Genotypes composed of two to five genes encoding interferon gamma -IFNG, transforming growth factor beta 1 -TGFB1, Janus kinase 2 -JAK2, thymic stromal lymphopoietin -TSLP, and involucrin -IVL were associated with IBH, indicating a role of the genes in the pathogenesis of IBH. These findings were supported by analysis of gene expression in skin biopsies of 15 affected and 15 unaffected horses. Two markers associated with IBH, IFNG and TGFB1, showed differences in mRNA expression in skin biopsies from IBH-affected and non-affected horses (p<0.05). Expression of the gene coding for the CD14 receptor molecule -CD14 was different in skin biopsies at p<0.06. When total IgE levels were treated as binary traits, genotypes of IGHE, ELA-DRA, and IL10/b were associated with this trait. When treated as a continuous trait, total IgE levels were associated with genes IGHE, FCER1A, IL4, IL4R, IL10, IL1RA, and JAK2. This first report on non-MHC genes associated with IBH in horses is thus supported by differences in expression of genes known to play a role in allergy and immunity.
- MeSH
- alergeny imunologie MeSH
- atopická dermatitida genetika imunologie veterinární MeSH
- Ceratopogonidae imunologie MeSH
- cytokiny genetika MeSH
- exprese genu MeSH
- hlavní histokompatibilní komplex MeSH
- imunoglobulin E krev MeSH
- interferon gama genetika MeSH
- Janus kinasa 2 genetika MeSH
- jednonukleotidový polymorfismus MeSH
- koně MeSH
- kousnutí a bodnutí hmyzem genetika imunologie veterinární MeSH
- messenger RNA genetika MeSH
- nemoci koní genetika imunologie MeSH
- proteinové prekurzory genetika MeSH
- slinné proteiny a peptidy imunologie MeSH
- transformující růstový faktor beta1 genetika MeSH
- zvířata MeSH
- Check Tag
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The paper describes experiments and their results that offered an insight to relationship between RR and QT intervals in equine ECG signals recorded under various conditions. In contrast to human heart in a great number of cases the QT intervals prolonged with a heart rate acceleration. Peak-to-peak differences between maximum and minimum RR intervals during the excitation response in non-standard responses were twice as smaller as in standard responses and the lengths of QT intervals were significantly longer in the non-standard records. This fact means that the electrical processes in equine heart ventricles must be controlled by different mechanisms than in human heart.
- MeSH
- anestezie metody škodlivé účinky využití MeSH
- elektrokardiografie metody využití MeSH
- financování organizované MeSH
- funkční vyšetření srdce metody využití MeSH
- kardiovaskulární systém patofyziologie účinky léků MeSH
- koně MeSH
- náhlá srdeční smrt etiologie prevence a kontrola MeSH
- teoretické modely MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH