Spinal cord injury (SCI) is a serious trauma, which often results in a permanent loss of motor and sensory functions, pain and spasticity. Despite extensive research, there is currently no available therapy that would restore the lost functions after SCI in human patients. Advanced treatments use regenerative medicine or its combination with various interdisciplinary approaches such as tissue engineering or biophysical methods. This review summarizes and critically discusses the research from specific interdisciplinary fields in SCI treatment such as the development of biomaterials as scaffolds for tissue repair, and using a magnetic field for targeted cell delivery. We compare the treatment effects of synthetic non-degradable methacrylate-based hydrogels and biodegradable biological scaffolds based on extracellular matrix. The systems using magnetic fields for magnetically guided delivery of stem cells loaded with magnetic nanoparticles into the lesion site are then suggested and discussed.
- MeSH
- biokompatibilní materiály farmakologie terapeutické užití MeSH
- hydrogely terapeutické užití MeSH
- lidé MeSH
- magnetoterapie metody trendy MeSH
- poranění míchy patofyziologie terapie MeSH
- regenerace nervu účinky léků fyziologie MeSH
- transplantace kmenových buněk metody trendy MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
BACKGROUND: The Heartmate 3 (HM3) is a Conformiteé Européenne mark-approved left ventricular (LV) assist device (LVAD) with fully magnetically levitated rotor and features consisting of a wide range operational speeds, wide flow paths, and artificial pulse. We performed a hemodynamic-echocardiographic speed optimization evaluation in HM3-implanted patients to achieve optimal LV- and right ventricular (RV) shape. METHODS AND RESULTS: Sixteen HM3 patients underwent pump speed ramp tests with right heart catheterization. Three-dimensional echocardiographic (3DE) LV and RV datasets (Philips) were acquired, and volumetric (Tomtec) and shape (custom software) analyses were performed (LV: sphericity, conicity; RV: septal and free-wall curvatures). Data were recorded at up to 13 speed settings. Speed changes were in 100-rpm steps, starting at 4600 rpm and ramping up to 6200 rpm. 3DE was feasible in 50% of the patients. Mean original speed was 5306 ± 148 rpm. LV end-diastolic (ED) diameter (-0.15 ± 0.09 cm/100 rpm) and volumes (ED: 269 ± 109 mL to 175 ± 90 mL; end-systolic [ES]: 234 ± 111 mL to 146 ± 81 mL) progressively decreased as the shape became less spherical and more conical; RV volumes initially remained stable, but at higher speeds increased (ED: from 148 ± 64 mL to 181 ± 92 mL; ES: 113 ± 63 mL to 130 ± 69 mL). On average, the RV septum became less convex (bulging toward the LV) at the highest speeds. CONCLUSIONS: LV and RV shape changes were noted in HM3-supported patients. Although a LV volumetric decrease and shape improvement was consistently noted, RV volumes grew in response to increase in speed above a certain point. A next concern would be whether understanding of morphologic and function changes in LV and RV during LVAD speed change assessed with the use of 3DE helps to optimize LVAD speed settings and improve clinical outcomes.
- MeSH
- echokardiografie trojrozměrná trendy MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetoterapie metody trendy MeSH
- podpůrné srdeční systémy trendy MeSH
- prospektivní studie MeSH
- senioři MeSH
- srdeční katetrizace metody trendy MeSH
- srdeční komory diagnostické zobrazování chirurgie MeSH
- srdeční selhání diagnostické zobrazování terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH