Active and passive samplers
Dotaz
Zobrazit nápovědu
Indoor air pollution has been recognized as an important risk factor for human health, especially in areas where people tend to spend most of their time indoors. Many semi-volatile organic compounds (SVOCs) have primarily indoor sources and are present in orders of magnitude higher concentrations indoors than outdoors. Despite this, awareness of SVOCs in indoor air and assessment of the link between indoor concentrations and human health have lagged behind those of outdoor air. This is partially related to challenges associated with indoor sampling of SVOCs. Passive air samplers (PASs), which are widely accepted in established outdoor air monitoring networks, have been used to fill the knowledge gaps on indoor SVOCs distribution. However, their applicability for indoor environments and the assessment of human health risks lack sufficient experimental data. To address this issue, we performed an indoor calibration study of polyurethane foam (PUF) PAS deployed in a double-dome chamber, covering both legacy and new SVOC classes. PUF-PAS and a continuous low-volume active air sampler (AAS) were co-deployed for a calibration period of twelve weeks. Based on the results from this evaluation, PUF-PAS in a double-bowl chamber is recommended for indoor sampling and health risk assessment of gas phase SVOCs, including novel brominated flame retardants (nBFR) providing sufficient exposure time is applied. Data for particle associated SVOCs suffered from significant uncertainties caused by low level of detection and low precision in this study. A more open chamber design for indoor studies may allow for higher sampling rates (RS) and better performance for the particle associated SVOCs.
- MeSH
- látky znečišťující vzduch analýza MeSH
- monitorování životního prostředí přístrojové vybavení metody MeSH
- polyurethany chemie MeSH
- směrnice jako téma * MeSH
- těkavé organické sloučeniny analýza MeSH
- znečištění vzduchu ve vnitřním prostředí analýza MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
This study was carried out in the framework of the ICON project (Integrated Assessment of Contaminant Impacts on the North Sea) (Hylland et al., 2015) and aimed (1) to evaluate the toxicity of marine sediments using a battery of rapid toxicity bioassays, and; (2) to explore the applicability and data interpretation of in vitro toxicity profiling of sediment extracts obtained from ex situ passive sampling. Sediment samples were collected at 12 selected (estuarine, coastal, offshore) sites in the North Sea, Icelandic waters (as reference sites), south-western Baltic Sea and western Mediterranean during autumn 2008. Organic extracts using a mild non-destructive clean-up procedure were prepared from total sediment and silicone passive samplers and tested with five in vitro bioassays: DR-Luc bioassay, ER-Luc bioassay, AR-EcoScreen bioassay, transthyretin (TTR) binding assay, and Vibrio fischeri bioluminescence bioassay. In vitro toxicity profiling of total sediment and silicone passive sampler extracts showed the presence of multiple organic contaminations by arylhydrocarbon receptor agonists (e.g. polycyclic aromatic hydrocarbons) and endocrine-active compounds, as well as non-specific toxicity caused by organic contaminants, at virtually all sampling sites. In vitro responses to total sediment extracts from coastal/estuarine sites were significantly different from those in offshore sites (p < 0.05). Several bioassays of passive sampler extracts showed highest activity in some offshore sediment samples. Impact on embryogenesis success and larval growth in undiluted sediment elutriates was shown at some sites using the in vivo sea urchin embryo test. The observed toxicity profiles could only partially be explained by the chemical target analysis, indicating the presence of unknown or unanalysed biologically-active compounds in the sediments. In vitro bioassay testing with silicone passive sampler extracts of sediments is a promising tool to assess the toxic potency of the bioavailable fraction of hydrophobic sediment contaminants, but further work will be needed before it can be routinely applied for sediment quality assessment.
- MeSH
- Aliivibrio fischeri MeSH
- biotest MeSH
- chemické látky znečišťující vodu toxicita MeSH
- geologické sedimenty chemie MeSH
- ježovky MeSH
- monitorování životního prostředí metody MeSH
- polycyklické aromatické uhlovodíky toxicita MeSH
- receptory aromatických uhlovodíků MeSH
- testy toxicity metody MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Severní moře MeSH
The concentrations of seven perfluoroalkyl substances (PFASs) were investigated in 36 European chub (Squalius cephalus) individuals from six localities in the Czech Republic. Chub muscle and liver tissue were analysed at all sampling sites. In addition, analyses of 16 target PFASs were performed in Polar Organic Chemical Integrative Samplers (POCISs) deployed in the water at the same sampling sites. We evaluated the possibility of using passive samplers as a standardized method for monitoring PFAS contamination in aquatic environments and the mutual relationships between determined concentrations. Only perfluorooctane sulphonate was above the LOQ in fish muscle samples and 52% of the analysed fish individuals exceeded the Environmental Quality Standard for water biota. Fish muscle concentration is also particularly important for risk assessment of fish consumers. The comparison of fish tissue results with published data showed the similarity of the Czech results with those found in Germany and France. However, fish liver analysis and the passive sampling approach resulted in different fish exposure scenarios. The total concentration of PFASs in fish liver tissue was strongly correlated with POCIS data, but pollutant patterns differed between these two matrices. The differences could be attributed to the metabolic activity of the living organism. In addition to providing a different view regarding the real PFAS cocktail to which the fish are exposed, POCISs fulfil the Three Rs strategy (replacement, reduction, and refinement) in animal testing.
- MeSH
- chemické látky znečišťující vodu analýza MeSH
- Cyprinidae metabolismus MeSH
- fluorokarbony analýza MeSH
- játra chemie MeSH
- kyseliny alkansulfonové analýza MeSH
- monitorování životního prostředí metody MeSH
- svaly chemie MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika MeSH
Many attempts have been made to quantify the relationship between the amount of persistent organic pollutants sequestered by passive air sampling devices and their actual concentrations in ambient air. However, this information may not be necessary for some applications. In this study, two sets of 30 ten-year-long time series of simultaneous passive and high-volume active air sampling carried out at the Košetice observatory in the Czech Republic were used for a comparison of temporal trends. Fifteen polyaromatic hydrocarbons, seven polychlorinated biphenyls and eight organochlorine pesticides were investigated. In most cases, a good agreement was observed between the trends derived from passive and active monitoring with the exception of several compounds obviously affected by sampling artifacts. Two sampling artifacts were observed: breakthrough of high-volume sampler filters for penta- and hexachlorobenzene and semiquantitative values for PAHs with a high molecular weight. It has been suggested before that annually aggregated results of passive air monitoring may be used directly for the assessment of the long-term behavior of these compounds. The extensive set of long-term data used in this study allowed us to confirm this finding and to demonstrate that it is also possible to derive temporal trends and the compounds' half-lives in air from the passive-sampling time series.
- MeSH
- chlorované uhlovodíky MeSH
- látky znečišťující vzduch MeSH
- monitorování životního prostředí * MeSH
- polychlorované bifenyly MeSH
- polycyklické aromatické uhlovodíky * MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Česká republika MeSH
Passive and composite sampling in combination with in vitro bioassays and identification and quantification of individual chemicals were applied to characterize pollution by compounds with several specific modes of action in urban area in the basin of two rivers, with 400,000 inhabitants and a variety of industrial activities. Two types of passive samplers, semipermeable membrane devices (SPMD) for hydrophobic contaminants and polar organic chemical integrative samplers (POCIS) for polar compounds such as pesticides and pharmaceuticals, were used to sample wastewater treatment plant (WWTP) influent and effluent as well as rivers upstream and downstream of the urban complex and the WWTP. Compounds with endocrine disruptive potency were detected in river water and WWTP influent and effluent. Year-round, monthly assessment of waste waters by bioassays documented estrogenic, androgenic and dioxin-like potency as well as cytotoxicity in influent waters of the WWTP and allowed characterization of seasonal variability of these biological potentials in waste waters. The WWTP effectively removed cytotoxic compounds, xenoestrogens and xenoandrogens. There was significant variability in treatment efficiency of dioxin-like potency. The study indicates that the WWTP, despite its up-to-date technology, can contribute endocrine disrupting compounds to the river. Riverine samples exhibited dioxin-like, antiestrogenic and antiandrogenic potencies. The study design enabled characterization of effects of the urban complex and the WWTP on the river. Concentrations of PAHs and contaminants and specific biological potencies sampled by POCIS decreased as a function of distance from the city.
- MeSH
- androgenní receptory metabolismus MeSH
- androgeny analýza farmakologie MeSH
- biotest MeSH
- chemické látky znečišťující vodu analýza farmakologie MeSH
- čištění vody MeSH
- dioxiny analýza farmakologie MeSH
- endokrinní disruptory analýza farmakologie MeSH
- estrogeny analýza farmakologie MeSH
- krysa rodu rattus MeSH
- monitorování životního prostředí MeSH
- nádorové buněčné linie MeSH
- odpadní voda chemie MeSH
- pesticidy analýza farmakologie MeSH
- polychlorované dibenzodioxiny analýza farmakologie MeSH
- polycyklické aromatické uhlovodíky analýza farmakologie MeSH
- receptory aromatických uhlovodíků metabolismus MeSH
- receptory pro estrogeny metabolismus MeSH
- řeky chemie MeSH
- skládková zařízení MeSH
- velkoměsta MeSH
- zvířata MeSH
- Check Tag
- krysa rodu rattus MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika MeSH
- velkoměsta MeSH
Much effort has been made to standardise sampling procedures, laboratory analysis, data analysis, etc. for semi volatile organic contaminants (SVOCs). Yet there are some unresolved issues in regards to comparing measurements from one of the most commonly used passive samplers (PAS), the polyurethane foam (PUF) disk PAS (PUF-PAS), between monitoring networks or different studies. One such issue is that there is no universal means to derive a sampling rate (Rs) or to calculate air concentrations (Cair) from PUF-PAS measurements for SVOCs. Cair was calculated from PUF-PAS measurements from a long-term monitoring program at a site in central Europe applying current understanding of passive sampling theory coupled with a consideration for the sampling of particle associated compounds. Cair were assessed against concurrent active air sampler (AAS) measurements. Use of "site-based/sampler-specific" variables: Rs, calculated using a site calibration, provided similar results for most gas-phase SVOCs to air concentrations derived using "default" values (commonly accepted Rs). Individual monthly PUF-PAS-derived air concentrations for the majority of the target compounds were significantly different (Wilcoxon signed-rank (WSR) test; p < 0.05) to AAS regardless of the input values (site/sampler based or default) used to calculate them. However, annual average PUF-PAS-derived air concentrations were within the same order of magnitude as AAS measurements except for the particle-phase polycyclic aromatic hydrocarbons (PAHs). Underestimation of PUF-derived air concentrations for particle-phase PAHs was attributed to a potential overestimation of the particle infiltration into the PUF-PAS chamber and underestimation of the particle bound fraction of PAHs.
- MeSH
- kalibrace MeSH
- látky znečišťující vzduch chemie MeSH
- monitorování životního prostředí přístrojové vybavení metody MeSH
- nejistota MeSH
- polyurethany chemie MeSH
- těkavé organické sloučeniny chemie MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Evropa MeSH
The freely dissolved concentration of persistent organic pollutants (POPs) is one of the most important parameters for risk assessment in aquatic environments, due to its proportionality to the chemical activity. Chemical activity difference represents the driving force for a spontaneous contaminant transport, such as water-aquatic biota or water-sediment. Freely dissolved concentrations in sediment pore water can be estimated from the concentrations in a partition-based passive sampler equilibrated in suspensions of contaminated sediment. Equilibration in the sediment/passive sampler system is slow, since concentrations of most POPs in the water phase, which is the main route for mass transfer, are very low. Adding methanol to sediment in suspension increases the POPs' solubility and, consequently, the permeability in the water phase. The resulting higher aqueous concentrations enhance POPs mass transfer up to three times for investigated POPs (polycyclic aromatic hydrocarbons, polychlorinated biphenyls, organochlorine pesticides) and shorten equilibrium attainment to less than 6 weeks. The addition of methanol to the aqueous phase up to a molar fraction of 0.2 changed the POPs equilibrium distribution ratio between sediment and passive sampler by less than a factor of two. As a result, the pore water concentrations of POPs, calculated from their amounts accumulated in a passive sampler, are affected by methanol addition not more than by the same factor.
- MeSH
- chemické látky znečišťující vodu analýza MeSH
- chlorované uhlovodíky analýza MeSH
- geologické sedimenty analýza MeSH
- methanol chemie MeSH
- monitorování životního prostředí metody MeSH
- pesticidy analýza MeSH
- polychlorované bifenyly analýza MeSH
- polycyklické aromatické uhlovodíky analýza MeSH
- rozpustnost MeSH
- Publikační typ
- časopisecké články MeSH
The most commonly used passive air sampler (PAS) (i.e. polyurethane foam (PUF) disk) is cheap, versatile, and capable of accumulating compounds present both in gas and particle phases. Its performance for particle associated compounds is however disputable. In this study, twelve sets of triplicate PUF-PAS were deployed outdoors for exposure periods of 1-12 weeks together with continuously operated active samplers, to characterize sampling efficiency and derive sampling rates (RS) for compounds belonging to 7 SVOC classes (including particle associated compounds). PUF-PAS efficiently and consistently sampled polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), polycyclic aromatic hydrocarbons (PAHs), and eight novel brominated flame retardant (nBFR) compounds. Low accuracy and lack of sensitivity was observed for most polychlorinated dibenzo-p-dioxins/furans PCDD/Fs and polybrominated diphenyl ethers (PBDEs) (under the conditions of this study), with the exception of some congeners which may be used as qualitative markers for their respective classes. Application of compound specific RS was found crucial for all compounds except PCBs. Sampling efficiency of the particle associated compounds was often low.
- MeSH
- chlorované uhlovodíky analýza MeSH
- látky znečišťující vzduch analýza MeSH
- monitorování životního prostředí přístrojové vybavení metody MeSH
- pesticidy analýza MeSH
- polychlorované bifenyly analýza MeSH
- polycyklické aromatické uhlovodíky analýza MeSH
- polyurethany chemie MeSH
- těkavé organické sloučeniny analýza MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
This study addresses human health concerns in the city of Temuco that are attributed to wood smoke and related pollutants associated with wood burning activities that are prevalent in Temuco. Polycyclic Aromatic Hydrocarbons (PAHs) were measured in air across urban and rural sites over three seasons in Temuco using polyurethane foam (PUF) disk passive air samplers (PUF-PAS). Concentrations of ΣPAHs (15 congeners) in air ranged from BDL to ∼70 ng m(-3) and were highest during the winter season, which is attributed to emissions from residential heating by wood combustion. The results for all three seasons showed that the PAH plume was widespread across all sites including rural sites on the outskirts of Temuco. Some interesting variations were observed between seasons in the composition of PAHs, which were attributed to differences in seasonal point sources. A comparison of the PAH composition in the passive samples with active samples (gas+particle phase) from the same site revealed similar congener profiles. Overall, the study demonstrated that the PUF disk passive air sampler provides a simple approach for measuring PAHs in air and for tracking effectiveness of pollution control measures in urban areas in order to improve public health.
- MeSH
- analýza hlavních komponent MeSH
- analýza nákladů a výnosů MeSH
- atmosféra MeSH
- dřevo chemie MeSH
- kouř MeSH
- látky znečišťující vzduch analýza MeSH
- monitorování životního prostředí metody MeSH
- počasí MeSH
- polycyklické aromatické uhlovodíky analýza MeSH
- řízení kvality MeSH
- roční období MeSH
- velkoměsta MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Chile MeSH
- velkoměsta MeSH
Water monitoring is of great importance, especially for water bodies in agricultural or industrial areas. Grab sampling is a widely used technique for aquatic monitoring but represents only a snapshot of the contaminant levels at a specific point in time. Passive sampling, on the other hand, is an integrative technique that provides an average concentration of contaminants representative of its deployment period. Thus, the current contamination by organochlorine pesticides, polychlorinated biphenyls (PCBs), and some currently used pesticides was assessed along the Quequén Grande River watershed (Argentina) using the integrative silicone rubber passive sampling technique in a year-long study. Silicone rubber samplers were deployed at 6 sampling sites selected according to different land uses (agricultural-livestock production, agricultural and urban activities) during 3 periods in 2014 and 2015. The organochlorine pesticides were dominated by endosulfan (sum of α-, β-endosulfan, endosulfan sulfate = 0.15-23.4 ng/L). The highest endosulfan levels were registered during the pesticide application period (December-March), exceeding the international water quality guidelines for protecting freshwater biota (3 ng/L). Compared with previous reports, no reductions in endosulfan levels were observed at the Quequén Grande River watershed. These results would suggest the illegal use of remaining stocks because water sampling was carried out after endosulfan was banned in Argentina. Chlorpyrifos was the second major pesticide found in water (0.02-4.3 ng/L), associated with its widespread usage on soybean crops. A reduction in levels of legacy pesticides (heptachlors, DDTs, dieldrin, and chlordanes) was evident compared with previous reports from 2007. Levels of PCBs were very low, indicating that probably only minor diffuse sources were still available along the Quequén Grande River watershed. Environ Toxicol Chem 2019;38:340-349. © 2018 SETAC.
- MeSH
- chemické látky znečišťující vodu analýza MeSH
- chemické techniky analytické MeSH
- monitorování životního prostředí metody MeSH
- pesticidy analýza MeSH
- polychlorované bifenyly analýza MeSH
- řeky chemie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Argentina MeSH