Cardiac substructure
Dotaz
Zobrazit nápovědu
BACKGROUND/PURPOSE: High doses to healthy cardiac substructures (CS) in stereotactic arrhythmia radioablation (STAR) raise concerns regarding potential treatment-induced cardio-toxicity. However, CS contours are not routinely created, hindering the understanding of the CS dose-effect relationships. To address this issue, the alignment of CS contouring was initiated within the STOPSTORM consortium. In this study, we developed and evaluated auto-contouring models trained to delineate CS and major vessels in ventricular tachycardia (VT) patients. METHODS: Eight centres provided standard treatment planning computed tomography (CT) and/or contrast-enhanced CT datasets of 55 VT patients, each including 16 CS. Auto-contouring models were trained to contour either large structures or small structures. Dice Similarity Coefficient (DSC), 95 % Hausdorff distance (HD95) and volume ratio (VR) were used to evaluate model performance versus inter-observer variation (IOV) on seven VT patient test cases. Significant differences were tested using the Mann-Whitney U test. RESULTS: The performance on the four chambers and the major vessels (median DSC: 0.88; HD95: 5.8-19.4 mm; VR: 1.09) was similar to the IOV (median DSC: 0.89; HD95: 4.8-14.0 mm; VR: 1.20). For the valves, model performance (median DSC: 0.37; HD95: 11.6 mm; VR: 1.63) was similar to the IOV (median DSC: 0.41; HD95: 12.4 mm; VR: 3.42), but slightly worse for the coronary arteries (median DSC: 0.33 vs 0.42; HD95: 24.4 mm vs 16.9 mm; VR: 1.93 vs 3.30). The IOV for these small structures remains large despite using contouring guidelines. CONCLUSION: CS auto-contouring models trained on VT patient data perform similarly to IOV. This allows for time-efficient evaluation of CS as possible organs-at-risk.
- MeSH
- komorová tachykardie * MeSH
- kritické orgány účinky záření MeSH
- lidé středního věku MeSH
- lidé MeSH
- plánování radioterapie pomocí počítače metody MeSH
- počítačová rentgenová tomografie * MeSH
- radiochirurgie * metody MeSH
- senioři MeSH
- srdce účinky záření MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
We aimed to determine the impact of Ca(2+)-related disorders induced in intact animal hearts on ultrastructure of the cardiomyocytes prior to occurrence of severe arrhythmias. Three types of acute experiments were performed that are known to be accompanied by disturbances in Ca(2+) handling. Langedorff-perfused rat or guinea pig hearts subjected to K(+)-deficient perfusion to induce ventricular fibrillation (VF), burst atrial pacing to induce atrial fibrillation (AF) and open chest pig heart exposed to intramyocardial noradrenaline infusion to induce ventricular tachycardia (VT). Tissue samples for electron microscopic examination were taken during basal condition, prior and during occurrence of malignant arrhythmias. Cardiomyocyte alterations preceding occurrence of arrhythmias consisted of non-uniform sarcomere shortening, disruption of myofilaments and injury of mitochondria that most likely reflected cytosolic Ca(2+) disturbances and Ca(2+) overload. These disorders were linked with non-uniform pattern of neighboring cardiomyocytes and dissociation of adhesive junctions suggesting defects in cardiac cell-to-cell coupling. Our findings identified heterogeneously distributed high [Ca(2+)](i)-induced subcellular injury of the cardiomyocytes and their junctions as a common feature prior occurrence of VT, VF or AF. In conclusion, there is a link between Ca(2+)-related disorders in contractility and coupling of the cardiomyocytes pointing out a novel paradigm implicated in development of severe arrhythmias.
- MeSH
- draslík MeSH
- homeostáza MeSH
- kardiomyocyty metabolismus ultrastruktura MeSH
- krysa rodu rattus MeSH
- morčata MeSH
- noradrenalin MeSH
- poruchy metabolismu vápníku komplikace patologie MeSH
- prasata MeSH
- srdeční arytmie etiologie metabolismus MeSH
- zvířata MeSH
- Check Tag
- krysa rodu rattus MeSH
- morčata MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: STereotactic Arrhythmia Radioablation (STAR) showed promising results in patients with refractory ventricular tachycardia. However, clinical data are scarce and heterogeneous. The STOPSTORM.eu consortium was established to investigate and harmonize STAR in Europe. The primary goal of this benchmark study was to investigate current treatment planning practice within the STOPSTORM project as a baseline for future harmonization. METHODS AND MATERIALS: Planning target volumes (PTVs) overlapping extracardiac organs-at-risk and/or cardiac substructures were generated for 3 STAR cases. Participating centers were asked to create single-fraction treatment plans with 25 Gy dose prescriptions based on in-house clinical practice. All treatment plans were reviewed by an expert panel and quantitative crowd knowledge-based analysis was performed with independent software using descriptive statistics for International Commission on Radiation Units and Measurements report 91 relevant parameters and crowd dose-volume histograms. Thereafter, treatment planning consensus statements were established using a dual-stage voting process. RESULTS: Twenty centers submitted 67 treatment plans for this study. In most plans (75%) intensity modulated arc therapy with 6 MV flattening filter free beams was used. Dose prescription was mainly based on PTV D95% (49%) or D96%-100% (19%). Many participants preferred to spare close extracardiac organs-at-risk (75%) and cardiac substructures (50%) by PTV coverage reduction. PTV D0.035cm3 ranged from 25.5 to 34.6 Gy, demonstrating a large variety of dose inhomogeneity. Estimated treatment times without motion compensation or setup ranged from 2 to 80 minutes. For the consensus statements, a strong agreement was reached for beam technique planning, dose calculation, prescription methods, and trade-offs between target and extracardiac critical structures. No agreement was reached on cardiac substructure dose limitations and on desired dose inhomogeneity in the target. CONCLUSIONS: This STOPSTORM multicenter treatment planning benchmark study not only showed strong agreement on several aspects of STAR treatment planning, but also revealed disagreement on others. To standardize and harmonize STAR in the future, consensus statements were established; however, clinical data are urgently needed for actionable guidelines for treatment planning.
- MeSH
- benchmarking * MeSH
- celková dávka radioterapie MeSH
- komorová tachykardie chirurgie radioterapie MeSH
- konsensus * MeSH
- kritické orgány * účinky záření MeSH
- lidé MeSH
- plánování radioterapie pomocí počítače * normy metody MeSH
- radiochirurgie * normy metody MeSH
- radioterapie s modulovanou intenzitou metody normy MeSH
- srdce účinky záření MeSH
- srdeční arytmie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- Geografické názvy
- Evropa MeSH
BACKGROUND AND PURPOSE: In patients with recurrent ventricular tachycardia (VT), STereotactic Arrhythmia Radioablation (STAR) shows promising results. The STOPSTORM.eu consortium was established to investigate and harmonise STAR treatment in Europe. The primary goals of this benchmark study were to standardise contouring of organs at risk (OAR) for STAR, including detailed substructures of the heart, and accredit each participating centre. MATERIALS AND METHODS: Centres within the STOPSTORM.eu consortium were asked to delineate 31 OAR in three STAR cases. Delineation was reviewed by the consortium expert panel and after a dedicated workshop feedback and accreditation was provided to all participants. Further quantitative analysis was performed by calculating DICE similarity coefficients (DSC), median distance to agreement (MDA), and 95th percentile distance to agreement (HD95). RESULTS: Twenty centres participated in this study. Based on DSC, MDA and HD95, the delineations of well-known OAR in radiotherapy were similar, such as lungs (median DSC = 0.96, median MDA = 0.1 mm and median HD95 = 1.1 mm) and aorta (median DSC = 0.90, median MDA = 0.1 mm and median HD95 = 1.5 mm). Some centres did not include the gastro-oesophageal junction, leading to differences in stomach and oesophagus delineations. For cardiac substructures, such as chambers (median DSC = 0.83, median MDA = 0.2 mm and median HD95 = 0.5 mm), valves (median DSC = 0.16, median MDA = 4.6 mm and median HD95 = 16.0 mm), coronary arteries (median DSC = 0.4, median MDA = 0.7 mm and median HD95 = 8.3 mm) and the sinoatrial and atrioventricular nodes (median DSC = 0.29, median MDA = 4.4 mm and median HD95 = 11.4 mm), deviations between centres occurred more frequently. After the dedicated workshop all centres were accredited and contouring consensus guidelines for STAR were established. CONCLUSION: This STOPSTORM multi-centre critical structure contouring benchmark study showed high agreement for standard radiotherapy OAR. However, for cardiac substructures larger disagreement in contouring occurred, which may have significant impact on STAR treatment planning and dosimetry evaluation. To standardize OAR contouring, consensus guidelines for critical structure contouring in STAR were established.
- MeSH
- benchmarking MeSH
- komorová tachykardie * radioterapie chirurgie MeSH
- koronární cévy MeSH
- lidé MeSH
- plánování radioterapie pomocí počítače * metody MeSH
- srdce MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH