BACKGROUND: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. It is urgently needed to better identify patients who benefit from prophylactic ICD therapy. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD) completed in 2019 will assess this issue. SUMMARY: The EU-CERT-ICD is a prospective investigator-initiated non-randomized, controlled, multicenter observational cohort study done in 44 centers across 15 European countries. A total of 2327 patients with heart failure due to ischemic heart disease or dilated cardiomyopathy indicated for primary prophylactic ICD implantation were recruited between 2014 and 2018 (>1500 patients at first ICD implantation, >750 patients non-randomized non-ICD control group). The primary endpoint was all-cause mortality, and first appropriate shock was co-primary endpoint. At baseline, all patients underwent 12‑lead ECG and Holter-ECG analysis using multiple advanced methods for risk stratification as well as documentation of clinical characteristics and laboratory values. The EU-CERT-ICD data will provide much needed information on the survival benefit of preventive ICD therapy and expand on previous prospective risk stratification studies which showed very good applicability of clinical parameters and advanced risk stratifiers in order to define patient subgroups with above or below average ICD benefit. CONCLUSION: The EU-CERT-ICD study will provide new and current data about effectiveness of primary prophylactic ICD implantation. The study also aims for improved risk stratification and patient selection using clinical risk markers in general, and advanced ECG risk markers in particular.
- MeSH
- defibrilátory implantabilní * MeSH
- elektrokardiografie MeSH
- lidé MeSH
- multicentrické studie jako téma MeSH
- náhlá srdeční smrt * prevence a kontrola MeSH
- pozorovací studie jako téma MeSH
- prospektivní studie MeSH
- srovnávací výzkum účinnosti * MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- Geografické názvy
- Evropa MeSH
AIM: The association of standard 12-lead electrocardiogram (ECG) markers with benefits of the primary prophylactic implantable cardioverter-defibrillator (ICD) has not been determined in the contemporary era. We analysed traditional and novel ECG variables in a large prospective, controlled primary prophylactic ICD population to assess the predictive value of ECG in terms of ICD benefit. METHODS AND RESULTS: Electrocardiograms from 1477 ICD patients and 700 control patients (EU-CERT-ICD; non-randomized, controlled, prospective multicentre study; ClinicalTrials.gov Identifier: NCT02064192), who met ICD implantation criteria but did not receive the device, were analysed. The primary outcome was all-cause mortality. In ICD patients, the co-primary outcome of first appropriate shock was used. Mean follow-up time was 2.4 ± 1.1 years to death and 2.3 ± 1.2 years to the first appropriate shock. Pathological Q waves were associated with decreased mortality in ICD patients [hazard ratio (HR) 0.54, 95% confidence interval (CI) 0.35-0.84; P < 0.01] and patients with pathological Q waves had significantly more benefit from ICD (HR 0.44, 95% CI 0.21-0.93; P = 0.03). QTc interval increase taken as a continuous variable was associated with both mortality and appropriate shock incidence, but commonly used cut-off values, were not statistically significantly associated with either of the outcomes. CONCLUSION: Pathological Q waves were a strong ECG predictor of ICD benefit in primary prophylactic ICD patients. Excess mortality among Q wave patients seems to be due to arrhythmic death which can be prevented by ICD.
- MeSH
- defibrilátory implantabilní * škodlivé účinky MeSH
- elektrokardiografie MeSH
- lidé MeSH
- náhlá srdeční smrt epidemiologie etiologie prevence a kontrola MeSH
- primární prevence metody MeSH
- prospektivní studie MeSH
- rizikové faktory MeSH
- srdeční arytmie diagnóza etiologie terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky kontrolované MeSH
- multicentrická studie MeSH
BACKGROUND: New methods to identify patients who benefit from a primary prophylactic implantable cardioverter-defibrillator (ICD) are needed. T-wave alternans (TWA) has been shown to associate with arrhythmogenesis of the heart and sudden cardiac death. We hypothesized that TWA might be associated with benefit from ICD implantation in primary prevention. METHODS AND RESULTS: In the EU-CERT-ICD (European Comparative Effectiveness Research to Assess the Use of Primary Prophylactic Implantable Cardioverter-Defibrillators) study, we prospectively enrolled 2327 candidates for primary prophylactic ICD. A 24-hour Holter monitor reading was taken from all recruited patients at enrollment. TWA was assessed from Holter monitoring using the modified moving average method. Study outcomes were all-cause death, appropriate shock, and survival benefit. TWA was assessed both as a contiguous variable and as a dichotomized variable with cutoff points <47 μV and <60 μV. The final cohort included 1734 valid T-wave alternans samples, 1211 patients with ICD, and 523 control patients with conservative treatment, with a mean follow-up time of 2.3 years. TWA ≥60 μV was a predicter for a higher all-cause death in patients with an ICD on the basis of a univariate Cox regression model (hazard ratio, 1.484 [95% CI, 1.024-2.151]; P=0.0374; concordance statistic, 0.51). In multivariable models, TWA was not prognostic of death or appropriate shocks in patients with an ICD. In addition, TWA was not prognostic of death in control patients. In a propensity score-adjusted Cox regression model, TWA was not a predictor of ICD benefit. CONCLUSIONS: T-wave alternans is poorly prognostic in patients with a primary prophylactic ICD. Although it may be prognostic of life-threatening arrhythmias and sudden cardiac death in several patient populations, it does not seem to be useful in assessing benefit from ICD therapy in primary prevention among patients with an ejection fraction of ≤35%.
- MeSH
- časové faktory MeSH
- defibrilátory implantabilní * MeSH
- elektrická defibrilace přístrojové vybavení škodlivé účinky MeSH
- elektrokardiografie ambulantní * metody MeSH
- hodnocení rizik metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- náhlá srdeční smrt * prevence a kontrola etiologie MeSH
- prediktivní hodnota testů MeSH
- primární prevence * metody MeSH
- prognóza MeSH
- prospektivní studie MeSH
- rizikové faktory MeSH
- senioři MeSH
- srdeční arytmie terapie patofyziologie diagnóza prevence a kontrola mortalita MeSH
- srdeční frekvence fyziologie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- Geografické názvy
- Evropa MeSH
Background: Implantable cardioverter defibrillators (ICDs) prevent sudden cardiac death. ICD implantation decisions are currently based on reduced left ventricular ejection fraction (LVEF≤35%). However, in some patients, the non-arrhythmic death risk predominates thus diminishing ICD-therapy benefits. Based on previous observations, we tested the hypothesis that compared to the others, patients with nocturnal respiratory rate (NRR) ≥18 breaths per minute (brpm) benefit less from prophylactic ICD implantations. Methods: This prospective cohort study was a pre-defined sub-study of EU-CERT-ICD trial conducted at 44 centers in 15 EU countries between May 12, 2014, and September 6, 2018. Patients with ischaemic or non-ischaemic cardiomyopathy were included if meeting primary prophylactic ICD implantation criteria. The primary endpoint was all-cause mortality. NRR was assessed blindly from pre-implantation 24-hour Holters. Multivariable models and propensity stratification evaluated the interaction between NRR and the ICD mortality effect. This study is registered with ClinicalTrials.gov (NCT0206419). Findings: Of the 2,247 EU-CERT-ICD patients, this sub-study included 1,971 with complete records. In 1,363 patients (61.7 (12) years; 244 women) an ICD was implanted; 608 patients (63.2 (12) years; 108 women) were treated conservatively. During a median 2.5-year follow-up, 202 (14.8%) and 95 (15.6%) patients died in the ICD and control groups, respectively. NRR statistically significantly interacted with the ICD mortality effect (p = 0.0070). While the 1,316 patients with NRR<18 brpm showed a marked ICD benefit on mortality (adjusted HR 0.529 (95% CI 0.376-0.746); p = 0.0003), no treatment effect was demonstrated in 655 patients with NRR≥18 brpm (adjusted HR 0.981 (95% CI 0.669-1.438); p = 0.9202). Interpretation: In the EU-CERT-ICD trial, patients with NRR≥18 brpm showed limited benefit from primary prophylactic ICD implantation. Those with NRR<18 brpm benefitted substantially. Funding: European Community's 7th Framework Programme FP7/2007-2013 (602299).
- Publikační typ
- časopisecké články MeSH
AIMS: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD) aims to assess its current clinical value. METHODS AND RESULTS: The EU-CERT-ICD is a prospective investigator-initiated non-randomized, controlled, multicentre observational cohort study performed in 44 centres across 15 European Union countries. We will recruit 2250 patients with ischaemic or dilated cardiomyopathy and a guideline indication for primary prophylactic ICD implantation. This sample will include 1500 patients at their first ICD implantation and 750 patients who did not receive a primary prevention ICD despite having an indication for it (non-randomized control group). The primary endpoint is all-cause mortality; the co-primary endpoint in ICD patients is time to first appropriate shock. Secondary endpoints include sudden cardiac death, first inappropriate shock, any ICD shock, arrhythmogenic syncope, revision procedures, quality of life, and cost-effectiveness. At baseline (and prior to ICD implantation if applicable), all patients undergo 12-lead electrocardiogram (ECG) and Holter ECG analysis using multiple advanced methods for risk stratification as well as detailed documentation of clinical characteristics and laboratory values. Genetic biobanking is also organized. As of August 2018, baseline data of 2265 patients are complete. All subjects will be followed for up to 4.5 years. CONCLUSIONS: The EU-CERT-ICD study will provide a necessary update about clinical effectiveness of primary prophylactic ICD implantation. This study also aims for improved risk stratification and patient selection using clinical and ECG risk markers.
- MeSH
- defibrilátory implantabilní * MeSH
- dilatační kardiomyopatie komplikace mortalita terapie MeSH
- elektrokardiografie MeSH
- hodnocení rizik * MeSH
- kvalita života MeSH
- lidé MeSH
- míra přežití trendy MeSH
- náhlá srdeční smrt epidemiologie etiologie prevence a kontrola MeSH
- následné studie MeSH
- primární prevence metody MeSH
- prospektivní studie MeSH
- výběr pacientů MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
- Geografické názvy
- Evropa MeSH