Husby, Michael P* Dotaz Zobrazit nápovědu
BACKGROUND: The subcutaneous implantable defibrillator (S-ICD) provides an alternative to the transvenous ICD for the prevention of sudden cardiac death, but has not been well studied in the most commonly treated transvenous ICD patient population, namely, primary prevention (PP) patients with left ventricular dysfunction. OBJECTIVE: The analyses in the present study were designed to compare clinical outcomes for PP patients with and without a reduced ejection fraction (EF) and secondary prevention (SP) patients implanted with the S-ICD. METHODS: All patients 18 years and older from the S-ICD IDE study and the EFFORTLESS Registry with available data as of November 18, 2013, were included (n = 856; mean follow-up duration 644 days). Outcomes were evaluated in 2 analyses: (1) comparing all PP patients (n = 603, 70.4%) with all SP patients (n = 253, 29.6%) and (2) comparing all PP patients with an EF ≤35% (n = 379) with those with an EF >35% (n = 149, 17.4%). RESULTS: No differences were observed in mortality, complications, inappropriate therapy, or ability to convert ventricular tachyarrhythmias between SP and PP patients. However, SP patients had a higher incidence of appropriate therapy than did PP patients (11.9% vs 5.0%; P = .0004). In the PP subanalysis, the cohort with an EF ≤35% had significantly older patients with more comorbidities and higher mortality (3.0% annually vs 0.0%). Despite these differences, device-related complications, conversion efficacy, and incidence of inappropriate shock therapies were not significantly different between PP subgroups. CONCLUSION: The S-ICD performs well in protecting patients with either PP or SP implant indications from sudden cardiac death. Within PP patients, device performance was independent of EF.
- MeSH
- defibrilátory implantabilní * MeSH
- dospělí MeSH
- dysfunkce levé srdeční komory * diagnóza patofyziologie MeSH
- elektrická defibrilace * škodlivé účinky přístrojové vybavení metody MeSH
- Kaplanův-Meierův odhad MeSH
- komorová tachykardie * mortalita terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- náhlá srdeční smrt prevence a kontrola MeSH
- primární prevence metody statistika a číselné údaje MeSH
- protetické vybavení MeSH
- registrace MeSH
- sekundární prevence metody statistika a číselné údaje MeSH
- senioři MeSH
- tepový objem MeSH
- výsledky a postupy - zhodnocení (zdravotní péče) MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
BACKGROUND: The entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) eliminates the need for transvenous leads, and therefore has the potential to improve lead-longevity and reduce lead-related complications. The S-ICD has a morphology-based sensing algorithm of which inappropriate shocks have been reported. METHODS: We analyzed the incidence, predictors and management of inappropriate shocks in the EFFORTLESS S-ICD Registry, which collects S-ICD implantation information and follow-up data from clinical centers in Europe and New Zealand. RESULTS: During a follow-up of 21 ± 13 months, 48 out of 581 S-ICD patients (71% male, age 49 ± 18 years) experienced 101 inappropriate shocks (8.3%). The most common cause was cardiac signal oversensing (73%), such as T-wave oversensing. Eighteen shocks (18%) were due to supraventricular tachycardias (SVT), of which 15 occurred in the shock-only zone. Cox-proportional hazard modeling using time-dependent covariates demonstrated that patients with a history of atrial fibrillation (HR 2.4) and patients with hypertrophic cardiomyopathy (HR 4.6) had an increased risk for inappropriate shocks, while programming the primary vector for sensing (from xyphoid to V6) reduced the risk. Reprogramming or optimization of SVT treatment after the first clinical event of inappropriate shock was successful in preventing further inappropriate shocks for cardiac oversensing and SVT events. CONCLUSIONS: Inappropriate shocks, mainly due to cardiac oversensing, occurred in 8.3% of the S-ICD patients. Patients with hypertrophic cardiomyopathy or a history of atrial fibrillation were at increased risk, warranting specific attention for sensing and programming in this population.
- MeSH
- analýza selhání vybavení statistika a číselné údaje MeSH
- defibrilátory implantabilní * škodlivé účinky normy MeSH
- dospělí MeSH
- elektrická defibrilace * škodlivé účinky metody MeSH
- fibrilace síní epidemiologie MeSH
- hypertrofická kardiomyopatie epidemiologie MeSH
- incidence MeSH
- komorová tachykardie terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- proporcionální rizikové modely MeSH
- rizikové faktory MeSH
- senioři MeSH
- standardní péče MeSH
- výsledek terapie MeSH
- zlepšení kvality MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Evropa MeSH
- Nový Zéland MeSH
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to defibrillate ventricular arrhythmias, avoiding drawbacks of transvenous leads. The global EFFORTLESS S-ICD (Evaluation oF FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD) registry is collecting outcomes in 985 patients during a 5-year follow-up. OBJECTIVES: The primary goal of the EFFORTLESS registry is to determine the safety of the S-ICD by evaluating complications and inappropriate shock rate. METHODS: This is the first report on the full patient cohort and study endpoints with follow-up ≥1 year. The predefined endpoints are 30- and 360-day complications, and shocks for atrial fibrillation or supraventricular tachycardia. RESULTS: Patients were followed for 3.1 ± 1.5 years and 82 completed the study protocol 5-year visit. Average age was 48 years, 28% were women, ejection fraction was 43 ± 18%, and 65% had a primary prevention indication. The S-ICD system and procedure complication rate was 4.1% at 30 days and 8.4% at 360 days. The 1-year complication rate trended toward improvement from the first to last quartile of enrollment (11.3% [quartile 1]) to 7.8% [quartile 2], 6.6% [quartile 3], and 7.4% [quartile 4]; quartile 1 vs. quartiles 2 to 4; p = 0.06). Few device extractions occurred due to need for antitachycardia (n = 5), or biventricular (n = 4) or bradycardia pacing (n = 1). Inappropriate shocks occurred in 8.1% at 1 year and 11.7% after 3.1 years. At implant, 99.5% of patients had a successful conversion of induced ventricular tachycardia or ventricular fibrillation. The 1- and 5-year rates of appropriate shock were 5.8% and 13.5%, respectively. Conversion success for discrete spontaneous episodes was 97.4% overall. CONCLUSIONS: This registry demonstrates that the S-ICD fulfills predefined endpoints for safety and efficacy. Midterm performance rates on complications, inappropriate shocks, and conversion efficacy were comparable to rates observed in transvenous implantable cardioverter-defibrillator studies. (Evaluation oF Factors ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD [The EFFORTLESS S-ICD Registry]; NCT01085435).
- MeSH
- časové faktory MeSH
- defibrilátory implantabilní * MeSH
- komorová tachykardie terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- registrace * MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH