BACKGROUND: There is currently significant interest in assessing the role of oxygen in the radiobiological effects at ultra-high dose rates. Oxygen modulation is postulated to play a role in the enhanced sparing effect observed in FLASH radiotherapy, where particles are delivered at 40-1000 Gy/s. Furthermore, the development of laser-driven accelerators now enables radiobiology experiments in extreme regimes where dose rates can exceed 109 Gy/s, and predicted oxygen depletion effects on cellular response can be tested. Access to appropriate experimental enviroments, allowing measurements under controlled oxygenation conditions, is a key requirement for these studies. We report on the development and application of a bespoke portable hypoxia chamber specifically designed for experiments employing laser-driven sources, but also suitable for comparator studies under FLASH and conventional irradiation conditions. MATERIALS AND METHODS: We used oxygen concentration measurements to test the induction of hypoxia and the maintenance capacity of the chambers. Cellular hypoxia induction was verified using hypoxia inducible factor-1α immunostaining. Calibrated radiochromic films and GEANT-4 simulations verified the dosimetry variations inside and outside the chambers. We irradiated hypoxic human skin fibroblasts (AG01522B) cells with laser-driven protons, conventional protons and reference 225 kVp X-rays to quantify DNA DSB damage and repair under hypoxia. We further measured the oxygen enhancement ratio for cell survival after X-ray exposure in normal fibroblast and radioresistant patient- derived GBM stem cells. RESULTS: Oxygen measurements showed that our chambers maintained a radiobiological hypoxic environment for at least 45 min and pathological hypoxia for up to 24 h after disconnecting the chambers from the gas supply. We observed a significant reduction in the 53BP1 foci induced by laser-driven protons, conventional protons and X-rays in the hypoxic cells compared to normoxic cells at 30 min post-irradiation. Under hypoxic irradiations, the Laser-driven protons induced significant residual DNA DSB damage in hypoxic AG01522B cells compared to the conventional dose rate protons suggesting an important impact of these extremely high dose-rate exposures. We obtained an oxygen enhancement ratio (OER) of 2.1 ± 0.1 and 2.5 ± 0.1 respectively for the AG01522B and patient-derived GBM stem cells for X-ray irradiation using our hypoxia chambers. CONCLUSION: We demonstrated the design and application of portable hypoxia chambers for studying cellular radiobiological endpoints after exposure to laser-driven protons at ultra-high dose, conventional protons and X-rays. Suitable levels of reduced oxygen concentration could be maintained in the absence of external gassing to quantify hypoxic effects. The data obtained provided indication of an enhanced residual DNA DSB damage under hypoxic conditions at ultra-high dose rate compared to the conventional protons or X-rays.
UHDpulse - Metrology for advanced radiotherapy using particle beams with ultra-high pulse dose rates is a recently started European Joint Research Project with the aim to develop and improve dosimetry standards for FLASH radiotherapy, very high energy electron (VHEE) radiotherapy and laser-driven medical accelerators. This paper gives a short overview about the current state of developments of radiotherapy with FLASH electrons and protons, very high energy electrons as well as laser-driven particles and the related challenges in dosimetry due to the ultra-high dose rate during the short radiation pulses. We summarize the objectives and plans of the UHDpulse project and present the 16 participating partners.
The main purpose of this paper is to quantitatively study the possibility of delivering dose distributions of clinical relevance with laser-driven proton beams. A Monte Carlo application has been developed with the Geant4 toolkit, simulating the ELIMED (MEDical and multidisciplinary application at ELI-Beamlines) transport and dosimetry beam line which is being currently installed at the ELI-Beamlines in Prague (CZ). The beam line will be used to perform irradiations for multidisciplinary studies, with the purpose of demonstrating the possible use of optically accelerated ion beams for therapeutic purposes. The ELIMED Geant4-based application, already validated against reference transport codes, accurately simulates each single element of the beam line, necessary to collect the accelerated beams and to select them in energy. Transversal dose distributions at the irradiation point have been studied and optimized to try to quantitatively answer the question if such kind of beam lines, and specifically the systems developed for ELIMED in Prague, will be actually able to transport ion beams not only for multidisciplinary applications, such as pitcher-catcher nuclear reactions (e.g. neutrons), PIXE analysis for cultural heritage and space radiation, but also for delivering dose patterns of clinical relevance in a future perspective of possible medical applications.
The CATANA proton therapy center was the first Italian clinical facility making use of energetic (62 MeV) proton beams for the radioactive treatment of solid tumors. Since the date of the first patient treatment in 2002, 294 patients have been successful treated whose majority was affected by choroidal and iris melanomas. In this paper, we report on the current clinical and physical status of the CATANA facility describing the last dosimetric studies and reporting on the last patient follow-up results. The last part of the paper is dedicated to the description of the INFN-LNS ongoing activities on the realization of a beamline for the transport of laser-accelerated ion beams for future applications. The ELIMED (ELI-Beamlines MEDical and multidisciplinary applications) project is introduced and the main scientific aspects will be described.
- Publication type
- Journal Article MeSH
Recent advances in miniaturized cell culture systems have facilitated the screening of media additives on productivity and protein quality attributes of mammalian cell cultures. However, intracellular components are not routinely measured due to the limited throughput of available analytical techniques. In this work, time profiling of intracellular nucleotides and nucleotide sugars of CHO-S cell fed-batch processes in a micro-scale bioreactor system was carried out using a recently developed high-throughput method based on matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry (TOF-MS). Supplementation of various media additives significantly altered the intracellular nucleotides and nucleotide sugars that are inextricably linked to the process of glycosylation. The results revealed that UDP-Gal synthesis appeared to be particularly limiting whereas the impact of elevated UDP-GlcNAc and GDP-Fuc levels on the final glycosylation patterns was only marginally important. In contrast, manganese and asparagine supplementation altered the glycan profiles without affecting intracellular components. The combination of miniaturized cell cultures and high-throughput analytical techniques serves therefore as a useful tool for future quality driven media optimization studies.
- MeSH
- CHO Cells MeSH
- Cricetulus MeSH
- Glycosylation MeSH
- Cricetinae MeSH
- Nucleotides analysis chemistry MeSH
- Antibodies analysis chemistry MeSH
- High-Throughput Nucleotide Sequencing methods MeSH
- Animals MeSH
- Check Tag
- Cricetinae MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
In laser-driven acceleration, ultra-short and intense laser pulses are focussed on targets to generate beams of ionising radiation. One of the most important issues to be addressed is personal monitoring. While traditional dosemeters were designed primarily for measurements in continuous fields, dosemeters for laser laboratories must be capable of working in pulsed fields of pulse length below 1 ps, in a single-shot regime up to the repetition rate of 1 kHz. Responses of conventional dosemeters (films, polyallyldiglycol carbonate, electronic personal dosemeter) to proton bunches of up to 30 MeV energy produced by South Korean PW laser system at the Advanced Photonics Research Institute, Gwangju Institute of Science and Technology were studied, both by means of Monte Carlo simulations and experimentally.
- MeSH
- Radiation Dosage * MeSH
- Radiation Dosimeters * MeSH
- Film Dosimetry instrumentation methods MeSH
- Glycols chemistry MeSH
- Radiation, Ionizing MeSH
- Calibration MeSH
- Lasers MeSH
- Humans MeSH
- Monte Carlo Method MeSH
- Radiation Monitoring instrumentation methods MeSH
- Plastics MeSH
- Computer Simulation MeSH
- Protons * MeSH
- Reproducibility of Results MeSH
- Carbonates chemistry MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Geographicals
- Republic of Korea MeSH
... for Cell Signaling 135 -- Proteins Can Be Pushed or Pulled into Different -- Shapes 135 -- Energy-driven ... ... -- Band III of the Human Red Blood Cell Membrane Is a Transport Protein -- Bacteriorhodopsin Is a Proton ... ... Released by the Passage of Electrons Along the Respiratoiy Chain Is Stored as an Electrochemical Proton ... ... Gradient Across the Inner Membrane The Energy Stored in the Electrochemical Proton Gradient Across the ... ... The Mechanisms of Respiratory Proton Pumping Are Not Well Understood -- 500 -- 500 -- 501 -- 502 -- ...
xxxix, 1146 s. : il., tab. ; 28 cm
- MeSH
- Cell Biology MeSH
- Molecular Biology MeSH
- Publication type
- Monograph MeSH
- Conspectus
- Biochemie. Molekulární biologie. Biofyzika
- NML Fields
- biologie
- cytologie, klinická cytologie