Lechner, Daniel*
Dotaz
Zobrazit nápovědu
BACKGROUND: Ixazomib-revlimid-dexamethason showed significant activity in relapsed/refractory multiple myeloma (RRMM). Here, we evaluate ixazomib in combination with thalidomide and dexamethasone for induction treatment followed by ixazomib maintenance therapy in RRMM patients. METHODS: Ninety patients have been included. Ixazomib-thalidomide-dexamethasone (4 mg, day 1, 8, 15; 100 mg daily; and 40 mg weekly) was scheduled for eight cycles followed by maintenance with ixazomib for one year. RESULTS: The overall response rate was 51.1%, 23.3% achieved CR or VGPR and 10% MR resulting in a clinical benefit rate of 61.1%. In patients completing ≥2 cycles, the rates were 60.5%, 27.6% and 68.4%, respectively. Median progression-free survival (PFS) was 8.5 months in all, and 9.4 months in those completing ≥2 cycles. Response rates, PFS and overall survival (OS) were similar in patients with and without t(4;14) and/or del(17p), but PFS and OS was significantly shorter in patients with gain of 1q21. Multivariate regression analysis revealed gain of 1q21 as the most important factor associated with OS. Ixazomib maintenance resulted in an upgrade in the depth of response in 12.4% of patients. Grade 3/4 toxicities were relatively rare. CONCLUSIONS: Ixazomib-thalidomide-dexamethasone followed by ixazomib maintenance therapy is active and well tolerated in patients with RRMM. TRIAL REGISTRATION NUMBER: NCT02410694.
- MeSH
- dexamethason aplikace a dávkování škodlivé účinky MeSH
- doba přežití bez progrese choroby MeSH
- dospělí MeSH
- glycin aplikace a dávkování škodlivé účinky analogy a deriváty MeSH
- indukční chemoterapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- míra přežití MeSH
- mnohočetný myelom farmakoterapie MeSH
- protokoly protinádorové kombinované chemoterapie škodlivé účinky terapeutické užití MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- sloučeniny boru aplikace a dávkování škodlivé účinky MeSH
- thalidomid aplikace a dávkování škodlivé účinky MeSH
- udržovací chemoterapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
- práce podpořená grantem MeSH
This trial evaluated quality of life (QoL) using the EORTC QLQ-C30 and the EORTC QLQ-MY20 instruments in 90 patients with relapsed/refractory multiple myeloma during induction and maintenance therapy with eight cycles of ixazomib-thalidomide-dexamethasone, followed by 12 months of ixazomib maintenance therapy. When patient's baseline QoL was compared with data of the general population, a significant impairment in health-related QoL, physical, role, and social functioning and several other dimensions, as well as more pain and fatigue, was noted. Induction therapy resulted in significant improvement of pain and worsening of neuropathy, with no significant variation of other parameters. During maintenance treatment, scores for most dimensions including health-related QoL, physical functioning and pain, improved, while for neuropathy no improvement was observed. Time to deterioration (≥10 score points) of health-related QoL, physical functioning, pain, and neuropathy was distinctly shorter than time to progression. Health-related QoL and physical functioning at baseline correlated with overall survival.
- MeSH
- dexamethason terapeutické užití MeSH
- glycin analogy a deriváty MeSH
- kvalita života * MeSH
- lidé MeSH
- mnohočetný myelom * farmakoterapie MeSH
- protokoly protinádorové kombinované chemoterapie terapeutické užití MeSH
- sloučeniny boru MeSH
- thalidomid terapeutické užití MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Introduction: Within an International Atomic Energy Agency (IAEA) co-ordinated research project (CRP), a remote end-to-end dosimetric quality audit for intensity modulated radiation therapy (IMRT)/ volumetric arc therapy (VMAT) was developed to verify the radiotherapy chain including imaging, treatment planning and dose delivery. The methodology as well as the results obtained in a multicentre pilot study and national trial runs conducted in close cooperation with dosimetry audit networks (DANs) of IAEA Member States are presented.Material and methods: A solid polystyrene phantom containing a dosimetry insert with an irregular solid water planning target volume (PTV) and organ at risk (OAR) was designed for this audit. The insert can be preloaded with radiochromic film and four thermoluminescent dosimeters (TLDs). For the audit, radiotherapy centres were asked to scan the phantom, contour the structures, create an IMRT/VMAT treatment plan and irradiate the phantom. The dose prescription was to deliver 4 Gy to the PTV in two fractions and to limit the OAR dose to a maximum of 2.8 Gy. The TLD measured doses and film measured dose distributions were compared with the TPS calculations.Results: Sixteen hospitals from 13 countries and 64 hospitals from 6 countries participated in the multicenter pilot study and in the national runs, respectively. The TLD results for the PTV were all within ±5% acceptance limit for the multicentre pilot study, whereas for national runs, 17 participants failed to meet this criterion. All measured doses in the OAR were below the treatment planning constraint. The film analysis identified seven plans in national runs below the 90% passing rate gamma criteria.Conclusion: The results proved that the methodology of the IMRT/VMAT dosimetric end-to-end audit was feasible for its intended purpose, i.e., the phantom design and materials were suitable; the phantom was easy to use and it was robust enough for shipment. Most importantly the audit methodology was capable of identifying suboptimal IMRT/VMAT delivery.
- MeSH
- celková dávka radioterapie MeSH
- fantomy radiodiagnostické * MeSH
- jaderná energie MeSH
- kritické orgány * MeSH
- lidé MeSH
- mezinárodní agentury MeSH
- pilotní projekty MeSH
- plánování radioterapie pomocí počítače metody MeSH
- počítačová rentgenová tomografie MeSH
- radiometrie metody normy MeSH
- radioterapie s modulovanou intenzitou metody normy MeSH
- revize kvality lékařské péče metody normy MeSH
- studie proveditelnosti MeSH
- zajištění kvality zdravotní péče MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
BACKGROUND AND OBJECTIVES: Research in Multiple Sclerosis (MS) has recently focused on extracting knowledge from real-world clinical data sources. This type of data is more abundant than data produced during clinical trials and potentially more informative about real-world clinical practice. However, this comes at the cost of less curated and controlled data sets. In this work we aim to predict disability progression by optimally extracting information from longitudinal patient data in the real-world setting, with a special focus on the sporadic sampling problem. METHODS: We use machine learning methods suited for patient trajectories modeling, such as recurrent neural networks and tensor factorization. A subset of 6682 patients from the MSBase registry is used. RESULTS: We can predict disability progression of patients in a two-year horizon with an ROC-AUC of 0.85, which represents a 32% decrease in the ranking pair error (1-AUC) compared to reference methods using static clinical features. CONCLUSIONS: Compared to the models available in the literature, this work uses the most complete patient history for MS disease progression prediction and represents a step forward towards AI-assisted precision medicine in MS.
- MeSH
- lidé MeSH
- neuronové sítě MeSH
- roztroušená skleróza * MeSH
- strojové učení * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
... .; Lechner, ?.; Wagner, A.; Emminger, W. ... ... W.; Gadner, H.; Hajek-Rosenmayr, A.; Fischer-Hinterberger, M.; Kos, M.; Emminger, W.; Panzer, S.; Lechner ...
Beiträge zur Infusionstherapie und klinische Ernährung ; Band 18
412 s. : il.