Omcirk, D, Vetrovsky, T, Padecky, J, Malecek, J, and Tufano, JJ. Validity of commercially available punch trackers. J Strength Cond Res 37(11): 2273-2281, 2023-This study determined how well data from commercially available punch trackers (Corner, Hykso, and StrikeTec) related to gold-standard velocity and force measures during full-contact punches. In a quasi-randomized order, 20 male subjects performed 6 individual rear straight punches, rear hooks, and rear uppercuts against a wall-mounted force plate. Punch tracker variables were compared with the peak force of the force plate and to the peak (QPV) and mean velocity (QMV) assessed through Qualisys 3-dimensional tracking. For each punch tracker variable, Pearson's correlation coefficient, mean absolute percentage error (MAPE), and mean percentage error (MPE) were calculated. There were no strong correlations between punch tracker data and gold-standard force and velocity data. However, Hykso "velocity" was moderately correlated with QMV ( r = 0.68, MAPE 0.64, MPE 0.63) and QPV ( r = 0.61, MAPE 0.21, MPE -0.06). Corner Power G was moderately correlated with QMV ( r = 0.59, MAPE 0.65, MPE 0.58) and QPV ( r = 0.58, MAPE 0.27, MPE -0.09), but Corner "velocity" was not. StrikeTec "velocity" was moderately correlated with QMV ( r = 0.56, MAPE 1.49, MPE 1.49) and QPV ( r = 0.55, MAPE 0.46, MPE 0.43). Therefore, none of the devices fared particularly well for all of their data output, and if not willing to accept any room for error, none of these devices should be used. Nevertheless, these devices and their proprietary algorithms may be updated in the future, which would warrant further investigation.
- MeSH
- Algorithms * MeSH
- Humans MeSH
- Reproducibility of Results MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Publication type
- Journal Article MeSH
INTRODUCTION: Although numerous activity trackers have been validated in healthy populations, validation is lacking in chronic heart failure patients who normally walk at a slower pace, making it difficult for researchers and clinicians to implement activity monitors during physical activity interventions. METHODS: Six consumer-level activity monitors were validated in a 3-day field study in patients with chronic heart failure and healthy individuals under free living conditions. Furthermore, the same devices were evaluated in a lab-based study during treadmill walking at speeds of 2.4, 3.0, 3.6, and 4.2 km·h-1. Concordance correlation coefficients (CCC) were used to evaluate the agreement between the activity monitors and the criterion, and mean absolute percentage errors (MAPE) were calculated to assess differences between each device and the criterion (MAPE <10% was considered as a threshold for validity). RESULTS: In the field study of healthy individuals, all but one of the activity monitors showed a substantial correlation (CCC ≥0.95) with the criterion device and MAPE <10%. In patients with heart failure, the correlation of only two activity monitors (Garmin vívofit 3 and Withings Go) was classified as at least moderate (CCC ≥0.90) and none of the devices had MAPE <10%. In the lab-based study at speeds 4.2 and 3.6 km·h-1, all activity monitors showed substantial to almost perfect correlations (CCC ≥0.95) with the criterion and MAPE in the range 1%-3%. However, at slower speeds of 3.0 and 2.4 km·h-1, the accuracy of all devices substantially deteriorated: their correlation with the criterion decreased below 90% and their MAPE increased to 4-8% and 10-45%, respectively. CONCLUSIONS: Even though none of the tested activity monitors fall within arbitrary thresholds for validity, most of them perform reasonably well enough to be useful tools that clinicians can use to simply motivate chronic heart failure patients to walk more.
- MeSH
- Accelerometry instrumentation methods MeSH
- Monitoring, Ambulatory instrumentation methods MeSH
- Chronic Disease MeSH
- Walking physiology MeSH
- Exercise physiology MeSH
- Adult MeSH
- Fitness Trackers MeSH
- Humans MeSH
- Reproducibility of Results MeSH
- Aged MeSH
- Heart Failure physiopathology MeSH
- Exercise Test instrumentation methods MeSH
- Check Tag
- Adult MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH