SQUAD(84) SPECFIT/32
Dotaz
Zobrazit nápovědu
Potentiometric and spectrophotometric pH-titration of the multiprotic cytostatics bosutinib for dissociation constants determination were compared. Bosutinib treats patients with positive chronic myeloid leukemia. Bosutinib exhibits four protonatable sites in a pH range from 2 to 11, where two pK are well separated (ΔpK>3), while the other two are near dissociation constants. In the neutral medium, bosutinib occurs in the slightly water soluble form LH that can be protonated to the soluble cation LH4(3+). The molecule LH can be dissociated to still difficultly soluble anion L(-). The set of spectra upon pH from 2 to 11 in the 239.3-375.0nm was divided into two absorption bands: the first one from 239.3 to 290.5nm and the second from 312.3 to 375.0nm, which differ in sensitivity of chromophores to a pH change. Estimates of pK of the entire set of spectra were compared with those of both absorption bands. Due to limited solubility of bosutinib the protonation in a mixed aqueous-methanolic medium was studied. In low methanol content of 3-6% three dissociation constants can be reliably determined with SPECFIT/32 and SQUAD(84) and after extrapolation to zero content of methanol they lead to pKc1=3.43(12), pKc2=4.54(10), pKc3=7.56(07) and pKc4=11.04(05) at 25°C and pKc1=3.44(06), pKc2=5.03(08) pKc3=7.33(05) and pKc4=10.92(06) at 37°C. With an increasing content of methanol in solvent the dissociation of bosutinib is suppressed and the percentage of LH3(2+) decreases and LH prevails. From the potentiometric pH-titration at 25°C the concentration dissociation constants were estimated with ESAB pKc1=3.51(02), pKc2=4.37(02), pKc3=7.97(02) and pKc4=11.05(03) and with HYPERQUAD: pKc1=3.29(12), pKc2=4.24(10), pKc3=7.95(07) and pKc4=11.29(05).
- MeSH
- aniliny analýza chemie MeSH
- chinoliny analýza chemie MeSH
- cytostatické látky analýza chemie MeSH
- koncentrace vodíkových iontů MeSH
- metoda nejmenších čtverců MeSH
- nelineární dynamika * MeSH
- nitrily analýza chemie MeSH
- potenciometrie MeSH
- spektrofotometrie metody MeSH
- Publikační typ
- časopisecké články MeSH
The resolving power of multicomponent spectral analysis and the computation reliability of the stability constants and molar absorptivities determined for five variously protonated anions of physostigmine salicylate by the SQUAD(84) and SPECFIT/32 programs has been examined with the use of simulated and experimental spectra containing overlapping spectral bands. The reliability of the dissociation constants of drug was proven with goodness-of-fit tests and by examining the influence of pre-selected noise level s(inst)(A) in synthetic spectra regarding the precision s(pK) and also accuracy of the estimated dissociation constants. Precision was examined as the linear regression model s(pK)=β(0)+β(1)s(inst)(A). In all cases the intercept β(0) was statistically insignificant. When an instrumental error s(inst)(A) is small and less than 0.5 mAU, the parameters' estimates are nearly the same as the bias ΔpK=pK(a,calc)-pK(a,true) is quite negligible. In all four dissociation constants the bias seems to be quite small even though for pK(a4) it is a little bit higher, i.e., +0.05 for s(inst)(A) about 1.0 mAU. In the interval of s(inst)(A) from 0.1 to 1.0 mAU all four dissociation constants pK(i) are accurate enough. Of the various regression diagnostics considered, the goodness-of-fit is the most efficient criterion of whether the parameters found adequately represent the data. The magnitude of instrumental error s(inst)(A) only slightly affects the shape of a Cattel's scree graph s(k)(A)=f(k) to determine the true number of light-absorbing species in the equilibrium mixture.
- MeSH
- absorpce MeSH
- chemické modely MeSH
- fysostigmin analýza chemie MeSH
- kinetika MeSH
- koncentrace vodíkových iontů MeSH
- počítačová simulace MeSH
- povrchové vlastnosti MeSH
- protony MeSH
- regresní analýza MeSH
- reprodukovatelnost výsledků MeSH
- software MeSH
- spektrofotometrie metody MeSH
- termodynamika MeSH
- titrace metody MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The mixed dissociation constants of four non-steroidal anti-inflammatory drugs (NSAIDs) ibuprofen, diclofenac sodium, flurbiprofen and ketoprofen at various ionic strengths I of range 0.003-0.155, and at temperatures of 25 degrees C and 37 degrees C, were determined with the use of two different multiwavelength and multivariate treatments of spectral data, SPECFIT/32 and SQUAD(84) nonlinear regression analyses and INDICES factor analysis. The factor analysis in the INDICES program predicts the correct number of components, and even the presence of minor ones, when the data quality is high and the instrumental error is known. The thermodynamic dissociation constant pK(a)(T) was estimated by nonlinear regression of (pK(a), I) data at 25 degrees C and 37 degrees C. Goodness-of-fit tests for various regression diagnostics enabled the reliability of the parameter estimates found to be proven. PALLAS, MARVIN, SPARC, ACD/pK(a) and Pharma Algorithms predict pK(a) being based on the structural formulae of drug compounds in agreement with the experimental value. The best agreement seems to be between the ACD/pK(a) program and experimentally found values and with SPARC. PALLAS and MARVIN predicted pK(a,pred) values with larger bias errors in comparison with the experimental value for all four drugs.
When drugs are poorly soluble then, instead of the potentiometric determination of dissociation constants, pH-spectrophotometric titration can be used along with nonlinear regression of the absorbance response surface data. Generally, regression models are extremely useful for extracting the essential features from a multiwavelength set of data. Regression diagnostics represent procedures for examining the regression triplet (data, model, method) in order to check (a) the data quality for a proposed model; (b) the model quality for a given set of data; and (c) that all of the assumptions used for least squares hold. In the interactive, PC-assisted diagnosis of data, models and estimation methods, the examination of data quality involves the detection of influential points, outliers and high leverages, that cause many problems when regression fitting the absorbance response hyperplane. All graphically oriented techniques are suitable for the rapid estimation of influential points. The reliability of the dissociation constants for the acid drug silybin may be proven with goodness-of-fit tests of the multiwavelength spectrophotometric pH-titration data. The uncertainty in the measurement of the pK (a) of a weak acid obtained by the least squares nonlinear regression analysis of absorption spectra is calculated. The procedure takes into account the drift in pH measurement, the drift in spectral measurement, and all of the drifts in analytical operations, as well as the relative importance of each source of uncertainty. The most important source of uncertainty in the experimental set-up for the example is the uncertainty in the pH measurement. The influences of various sources of uncertainty on the accuracy and precision are discussed using the example of the mixed dissociation constants of silybin, obtained using the SQUAD(84) and SPECFIT/32 regression programs.
- MeSH
- antioxidancia analýza chemie MeSH
- časové faktory MeSH
- chemické modely MeSH
- financování organizované MeSH
- koncentrace vodíkových iontů MeSH
- léčivé přípravky chemie MeSH
- metoda nejmenších čtverců MeSH
- regresní analýza MeSH
- silymarin analýza chemie MeSH
- spektrofotometrie metody MeSH
- stabilita léku MeSH
- titrace metody MeSH