Stereotactic body radiotherapy (SBRT) has been suggested as a promising therapeutic alternative in cases of failed catheter ablation for recurrent ventricular tachycardias (VTs) in patients with structural heart disease. This case series is the first postmortem immunohistochemical analysis of morphologic changes in the myocardium early and late after SBRT. The present findings are in line with experimental observations on apoptosis followed by fibrosis. This may explain why the effect of SBRT on VT is not predominantly immediate. Together with observation of early recurrences after SBRT for VT, these data suggest that this strategy may have rather delayed antiarrhythmic effects.
- Klíčová slova
- catheter ablation, histology, immunohistochemistry, radiotherapy, ventricular tachycardia,
- MeSH
- katetrizační ablace * MeSH
- komorová tachykardie * etiologie chirurgie MeSH
- lidé MeSH
- myokard MeSH
- radiochirurgie * škodlivé účinky MeSH
- srdeční komory chirurgie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
BACKGROUND/AIM: Immunotherapy with checkpoint inhibitors is currently considered a cornerstone of metastatic renal clear cell cancer (mRCC) therapy. Despite the general improvement in the survival of patients with mRCC, there are some clinical situations that have not been specifically evaluated in clinical trials, such as the use of everolimus before nivolumab. PATIENTS AND METHODS: We performed a retrospective analysis evaluating the efficacy of nivolumab in the real-world setting, including a subset of patients with previous mTOR inhibitor therapy. RESULTS: From a total of 56 patients, 25 were pre-treated with everolimus before receiving nivolumab. The overall progression-free survival (PFS), overall survival (OS), and objective response rate were 10.3, 21.3 months, and 34%, respectively. There were no statistically significant differences in patients who were or were not pre-treated with everolimus. CONCLUSION: mRCC patients should be treated with checkpoint inhibitors and prior use of mTOR inhibitors should not be a definitive exclusion criterium.
- Klíčová slova
- Renal cell cancer, mTOR inhibitor, neutrophil-lymphocyte ratio, nivolumab, platelet-lymphocyte ratio, systematic inflammation index,
- MeSH
- karcinom z renálních buněk * farmakoterapie MeSH
- lidé MeSH
- nádory ledvin * farmakoterapie MeSH
- nivolumab MeSH
- retrospektivní studie MeSH
- TOR serin-threoninkinasy MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- MTOR protein, human MeSH Prohlížeč
- nivolumab MeSH
- TOR serin-threoninkinasy MeSH
PURPOSE: We evaluated the efficiency and toxicity of stereotactic hypofractionated boost in combination with conventionally fractionated radiotherapy in the treatment of advanced floor of the mouth cancer. METHODS: Thirty-seven patients with advanced stage of the floor of the mouth cancer, histologically confirmed squamous cell carcinoma (p16 negative) ineligible for surgical treatment, were indicated for radiochemotherapy or hyperfractionated accelerated radiotherapy (HART). The radiotherapy protocol combined external beam radiotherapy (EBRT) and a stereotactic hypofractionated boost to the primary tumor. The dose delivered from EBRT was 70-72.5 Gy in 35/50 fractions. The hypofractionated boost followed with 10 Gy in two fractions. For the variables-tumor volume, stage and grade a multivariate analysis was performed to find the relationship between overall survival, local progression and metastasis. Toxicity was evaluated according to CTCAE scale version 4. RESULTS: After a median follow-up of 16 months, 23 patients (62%) achieved complete remission. The median time to local progression and metastasis was 7 months. Local control (LC) at 2 and 5-years was 70% and 62%, respectively. Progression-free survival (PFS) and overall survival (OS) were 57% and 49% at 2 years and 41% and 27% at 5 years, respectively. Statistical analysis revealed that larger tumors had worse overall survival and a greater chance of metastasis. Log-Rank GTV > 44 ccm (HR = 1.96; [95% CI (0.87; 4.38)]; p = 0.11). No boost-related severe acute toxicity was observed. Late osteonecrosis was observed in 3 patients (8%). CONCLUSION: The combination of EBRT and stereotactic hypofractionated boost is safe and seems to be an effective option for dose escalation in patients with advanced floor of the mouth tumors who are ineligible for surgical treatment and require a non-invasive approach.
- Klíčová slova
- CyberKnife, CyberKnife boost, Floor of the mouth tumor, Hypofractionated boost, Oral cavity tumor, Stereotactic radiotherapy,
- MeSH
- chemoradioterapie MeSH
- dospělí MeSH
- frakcionace dávky záření * MeSH
- kombinovaná terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- nádory úst mortalita patologie radioterapie MeSH
- následné studie MeSH
- pilotní projekty MeSH
- progrese nemoci MeSH
- radiochirurgie metody MeSH
- radioterapie s modulovanou intenzitou metody MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- spinocelulární karcinom mortalita patologie radioterapie MeSH
- studie proveditelnosti MeSH
- tumor burden MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
- Geografické názvy
- Česká republika epidemiologie MeSH
BACKGROUND: Here we aimed to evaluate the respiratory and cardiac-induced motion of a ICD lead used as surrogate in the heart during stereotactic body radiotherapy (SBRT) of ventricular tachycardia (VT). Data provides insight regarding motion and motion variations during treatment. MATERIALS AND METHODS: We analyzed the log files of surrogate motion during SBRT of ventricular tachycardia performed in 20 patients. Evaluated parameters included the ICD lead motion amplitudes; intrafraction amplitude variability; correlation error between the ICD lead and external markers; and margin expansion in the superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) directions to cover 90% or 95% of all amplitudes. RESULTS: In the SI, LL, and AP directions, respectively, the mean motion amplitudes were 5.0 ± 2.6, 3.4. ± 1.9, and 3.1 ± 1.6 mm. The mean intrafraction amplitude variability was 2.6 ± 0.9, 1.9 ± 1.3, and 1.6 ± 0.8 mm in the SI, LL, and AP directions, respectively. The margins required to cover 95% of ICD lead motion amplitudes were 9.5, 6.7, and 5.5 mm in the SI, LL, and AP directions, respectively. The mean correlation error was 2.2 ± 0.9 mm. CONCLUSIONS: Data from online tracking indicated motion irregularities and correlation errors, necessitating an increased CTV-PTV margin of 3 mm. In 35% of cases, the motion variability exceeded 3 mm in one or more directions. We recommend verifying the correlation between CTV and surrogate individually for every patient, especially for targets with posterobasal localization where we observed the highest difference between the lead and CTV motion.
- Klíčová slova
- stereotactic body radiotherapy, ventricular tachycardia,
- Publikační typ
- časopisecké články MeSH
BACKGROUND AND AIMS: Modern stereotactic body radiotherapy (SBRT) techniques and systems that use online image guidance offer frameless radiotherapy of spinal tumors and the ability to control intrafraction motion during treatment. These systems allow precise alignment of the patient during the entire treatment session and react immediately to random changes in this alignment. Online tracking data provide information about intrafractional changes, and this information can be useful for designing treatment strategies even if online tracking is not being used. The present study evaluated spine motion during SBRT treatment to assess the risk of verifying patient alignment only prior to starting treatment. METHODS: This study included 123 patients treated with spine SBRT. We analyzed different locations within the spine using system log files generated during treatment, which contain information about differences in the pretreatment reference spine positions by CT versus positions during SBRT treatment. The mean spine motion and intra/interfraction motion was evaluated. We defined and assessed the spine stability and spine significant shifts (SSHs) during treatment. RESULTS: We analyzed 462 fractions. For the cervical (C) spine, the greatest shifts were in the anterior-posterior (AP) direction (2.48 mm) and in pitch rotation (1.75 deg). The thoracic (Th) spine showed the biggest shift in the AP direction (3.68 mm) and in roll rotation (1.66 deg). For the lumbar-sacral (LS) spine, the biggest shift was found for left-right (LR) translation (3.81 mm) and roll rotation (3.67 deg). No C spine case exceeded 1 mm/1 deg for interfraction variability, but 7 of 54 Th spine cases exceeded 1 mm interfraction variability for translations (maximum value, 2.5 mm in the AP direction). The interfraction variability for translations exceeded 1 mm in 2 of 24 LS spine cases (maximum value, 1.7 mm in the LR direction). Only 13% of cases had no SSHs. The mean times to SSH were 6.5±3.9 min, 8.1±5.9 min, and 8.8±7.1 min for the C, Th, and LS spine, respectively, and the mean recorded SSH values were 1.6±0.66, 1.43±0.33, and 1.46±0.47 mm/deg, respectively. CONCLUSION: Positional tracking during spine SBRT treatments revealed low mean translational and rotational shifts. Patient immobilization did not improve spine shifts compared with our results for the Th and LS spine without immobilization. For the most precise spine SBRT, we recommend checking the patient's position during treatment.
- Klíčová slova
- SBRT, intrafraction variability, spine,
- MeSH
- bederní obratle MeSH
- frakcionace dávky záření MeSH
- hrudní obratle MeSH
- krční obratle MeSH
- křížová kost MeSH
- lidé MeSH
- nádory páteře radioterapie MeSH
- počítačová rentgenová tomografie MeSH
- pohyb * MeSH
- polohování pacienta MeSH
- radiochirurgie metody MeSH
- radioterapie řízená obrazem metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE/OBJECTIVE: To evaluate lung tumor motion during respiration and to describe factors affecting the range and variability of motion in patients treated with stereotactic ablative radiation therapy. METHODS AND MATERIALS: Log file analysis from online respiratory tumor tracking was performed in 145 patients. Geometric tumor location in the lungs, tumor volume and origin (primary or metastatic), sex, and tumor motion amplitudes in the superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) directions were recorded. Tumor motion variability during treatment was described using intrafraction/interfraction amplitude variability and tumor motion baseline changes. Tumor movement dependent on the tumor volume, position and origin, and sex were evaluated using statistical regression and correlation analysis. RESULTS: After analysis of >500 hours of data, the highest rates of motion amplitudes, intrafraction/interfraction variation, and tumor baseline changes were in the SI direction (6.0 ± 2.2 mm, 2.2 ± 1.8 mm, 1.1 ± 0.9 mm, and -0.1 ± 2.6 mm). The mean motion amplitudes in the lower/upper geometric halves of the lungs were significantly different (P<.001). Motion amplitudes >15 mm were observed only in the lower geometric quarter of the lungs. Higher tumor motion amplitudes generated higher intrafraction variations (R=.86, P<.001). Interfraction variations and baseline changes >3 mm indicated tumors contacting mediastinal structures or parietal pleura. On univariate analysis, neither sex nor tumor origin (primary vs metastatic) was an independent predictive factor of different movement patterns. Metastatic lesions in women, but not men, showed significantly higher mean amplitudes (P=.03) and variability (primary, 2.7 mm; metastatic, 4.9 mm; P=.002) than primary tumors. CONCLUSION: Online tracking showed significant irregularities in lung tumor movement during respiration. Motion amplitude was significantly lower in upper lobe tumors; higher interfraction amplitude variability indicated tumors in contact with mediastinal structures, although adhesion to parietal pleura did not necessarily reduce tumor motion amplitudes. The most variable lung tumors were metastatic lesions in women.
- MeSH
- analýza rozptylu MeSH
- časové faktory MeSH
- čtyřrozměrná počítačová tomografie MeSH
- dýchání * MeSH
- frakcionace dávky záření MeSH
- lidé MeSH
- nádory plic diagnostické zobrazování patologie radioterapie sekundární MeSH
- pohyb těles MeSH
- pohyb * MeSH
- radiochirurgie * MeSH
- regresní analýza MeSH
- sexuální faktory MeSH
- tumor burden MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
AIM: To evaluate the treatment plans of 3D image-guided brachytherapy (BT) and stereotactic robotic radiotherapy with online image guidance - CyberKnife (CK) in patients with locally advanced cervix cancer. METHODS AND MATERIALS: Ten pairs of plans for patients with locally advanced inoperable cervical cancer were created using MR based 3D brachytherapy and stereotaxis CK. The dose that covers 98% of the target volume (HR CTV D98) was taken as a reference and other parameters were compared. RESULTS: Of the ten studied cases, the dose from D100 GTV was comparable for both devices, on average, the BT GTV D90 was 10-20% higher than for CK. The HR CTV D90 was higher for CK with an average difference of 10-20%, but only fifteen percent of HR CTV (the peripheral part) received a higher dose from CK, while 85% of the target volume received higher doses from BT. We found a significant organ-sparing effect of CK compared to brachytherapy (20-30% lower doses in 0.1 cm(3), 1 cm(3), and 2 cm(3)). CONCLUSION: BT remains to be the best method for dose escalation. Due to the significant organ-sparing effect of CK, patients that are not candidates for BT could benefit from stereotaxis more than from classical external beam radiotherapy.
- Klíčová slova
- Brachytherapy, Cervix carcinoma, CyberKnife, Dosimetric study, Stereotactic radiotherapy,
- Publikační typ
- časopisecké články MeSH
PURPOSE: We retrospectively assessed the treatment results of patients with testicular non-seminoma to evaluate possible predictive and prognostic factors. METHODS: 189 patients with testicular non-seminoma treated between 2000 and 2012 were retrospectively evaluated. Treatment was based on orchiectomy plus chemotherapy (bleomycin/etoposide/cisplatin and vinblastine/ifosfamide/ cisplatin); retroperitoneal lymphadenectomy was only performed for residual disease after chemotherapy. The treatment protocol was updated regularly according to international standards. Overall survival (OS) was evaluated with the Kaplan-Meier method at a significance level of 5% according to stage, Karnofsky performance status (KPS), and chemotherapy dose intensity. RESULTS: OS differed significantly for patients at different TNM stages (p=0.000); however, detailed analysis revealed significantly worse survival only in stage IIIC (10-year OS for IIIC vs IIIA+B, 35 vs 88%, p=0.001), while the difference between IIIB and lower stages was not significant (p=0.383). Patients with no chemotherapy dose reduction had significantly higher OS than those with any kind of dose reduction (10-year OS 96 vs 0%, p=0.000). For stage IIIC disease, however, dose intensity had no influence on OS (p=0.167). KPS had no prognostic significance for OS (KPS<80 vs ≥80, p=0.627) for stage IIIA+B and for stage IIIC. CONCLUSION: The standard of care for testicular non-seminoma offers excellent prognosis with no significant differences in OS for good- and intermediate-risk patients. Reduction of chemotherapy dose negatively impacted OS in patients with stage IIIA+B and thus should be avoided.
- MeSH
- dospělí MeSH
- germinální a embryonální nádory mortalita patologie terapie MeSH
- kombinovaná terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- retrospektivní studie MeSH
- riziko MeSH
- senioři MeSH
- staging nádorů MeSH
- testikulární nádory mortalita patologie terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH