INTRODUCTION: A variable proportion of non-responders to cardiac resynchronization therapy (CRT) warrants the search for new approaches to optimize the position of the left ventricular (LV) lead and the CRT device programming. CineECG is a novel ECG modality proposed for the spatial visualization and quantification of myocardial depolarization and repolarization sequences. OBJECTIVE: The present study aimed to evaluate CineECG-derived parameters in different pacing modes and to test their associations with acute hemodynamic responses in CRT patients. METHODS AND RESULTS: CineECG was used to construct the average electrical path within the cardiac anatomy from the 12-lead ECG. CineECG and LV dP/dt max were tested in 15 patients with nonischemic dilated cardiomyopathy and left bundle branch block (QRS: 170 ± 17 ms; LVEF: 26 ± 5.5%) under pacing protocols with different LV lead localizations. The CineECG-derived path directions were computed for the QRS and ST-T intervals for the anteroposterior (Xh), interventricular (Yh), and apicobasal (Zh) axes. In a multivariate linear regression analysis with adjustment for the pacing protocol type, the ST-T path direction Yh was independently associated with the increase in dP/dt max during CRT, [regression coefficient 639.4 (95% confidence interval: 187.9-1090.9), p = 0.006]. In ROC curve analysis, the ST-T path direction Yh was associated with the achievement of a 10% increase in dP/dt max (AUC: 0.779, p = 0.002) with the optimal cut-off > 0.084 (left-to-right direction) with sensitivity 0.67 and specificity 0.92. CONCLUSION: The acute hemodynamic response in CRT patients was associated with specific CineECG repolarization sequence parameters, warranting their further testing as potential predictors of clinical outcomes.
- Klíčová slova
- cardiac resynchronization therapy, heart failure, hemodynamics, multipoint pacing, multisite pacing, repolarization,
- MeSH
- akční potenciály * MeSH
- blokáda Tawarova raménka * patofyziologie terapie diagnóza MeSH
- časové faktory MeSH
- dilatační kardiomyopatie * patofyziologie terapie diagnóza MeSH
- elektrokardiografie * MeSH
- funkce levé komory srdeční * MeSH
- hemodynamika * MeSH
- lidé středního věku MeSH
- lidé MeSH
- prediktivní hodnota testů MeSH
- senioři MeSH
- srdeční frekvence MeSH
- srdeční resynchronizační terapie * MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
INTRODUCTION: Left bundle branch area pacing (LBBAP) comprises pacing at the left ventricular septum (LVSP) or left bundle branch (LBBP). The aim of the present study was to investigate the differences in ventricular electrical heterogeneity between LVSP, LBBP, right ventricular pacing (RVP) and intrinsic conduction with different dyssynchrony measures using the ECG, vectorcardiograpy, ECG belt, and Ultrahigh frequency (UHF-)ECG. METHODS: Thirty-seven patients with a pacemaker indication for bradycardia or cardiac resynchronization therapy underwent LBBAP implantation. ECG, vectorcardiogram, ECG belt and UHF-ECG signals were recorded during RVP, LVSP and LBBP, and intrinsic activation. QRS duration (QRSd) was measured from the ECG, QRS area was calculated from the vectorcardiogram, LV activation time (LVAT) and standard deviation of activation time (SDAT) from ECG belt and electrical dyssynchrony (e-DYS16) from UHF-ECG. RESULTS: Both LVSP and LBBP significantly reduced ventricular electrical heterogeneity as compared to underlying LBBB and RV pacing in terms of QRS area (p < .001), SDAT (p < .001), LVAT (p < .001) and e-DYS16 (p < .001). QRSd was only reduced as compared to RV pacing(p < .001). QRS area was similar during LBBP and normal intrinsic conduction, e-DYS16 was similar during LVSP and normal intrinsic conduction, whereas SDAT was similar for LVSP, LBBP and normal intrinsic conduction. For all these variables there was no significant difference between LVSP and LBBP. CONCLUSION: Both LVSP and LBBP resulted in a more synchronous LV activation than LBBB and RVP. Especially LBBP resulted in levels of LV synchrony comparable to normal intrinsic conduction.
- Klíčová slova
- bradycardia pacing, cardiac resynchronization therapy, conduction system pacing, dyssynchrony, left bundle branch area pacing,
- MeSH
- akční potenciály * MeSH
- blokáda Tawarova raménka patofyziologie terapie diagnóza MeSH
- bradykardie patofyziologie terapie diagnóza MeSH
- časové faktory MeSH
- elektrofyziologické techniky kardiologické MeSH
- elektrokardiografie MeSH
- funkce levé komory srdeční * MeSH
- Hisův svazek * patofyziologie MeSH
- kardiostimulace umělá * MeSH
- lidé středního věku MeSH
- lidé MeSH
- mezikomorová přepážka * patofyziologie MeSH
- prediktivní hodnota testů * MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- srdeční frekvence * MeSH
- srdeční resynchronizační terapie MeSH
- vektorkardiografie * metody MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
BACKGROUND: The clinical impact of Periprocedural myocardial injury (PMI) in patients undergoing permanent pacemaker implantation with Left Bundle Branch Area Pacing (LBBAP) is unknown. METHODS: 130 patients undergoing LBBAP from January 2020 to June 2021 and completing 12 months follow up were enrolled to assess the impact of PMI on composite clinical outcome (CCO) defined as any of the following: all-cause death, hospitalization for heart failure (HHF), hospitalization for acute coronary syndrome (ACS) and ventricular arrhythmias (VAs). High sensitivity Troponin T (HsTnT) was measured up to 24-h after intervention to identify the peak HsTnT values. PMI was defined as increased peak HsTnT values at least > 99th percentile of the upper reference limit (URL: 15 pg/ml) in patients with normal baseline values. RESULTS: PMI occurred in 72 of 130 patients (55%). ROC analysis yielded a post-procedural peak HsTnT cutoff of fourfold the URL for predicting the CCO (AUC: 0.692; p = 0.023; sensitivity 73% and specificity 71%). Of the enrolled patients, 20% (n = 26) had peak HsTnT > fourfold the URL. Patients with peak HsTnT > fourfold the URL exhibited a higher incidence of the CCO than patients with peak HsTnT ≤ fourfold the URL (31% vs. 10%; p = 0.005), driven by more frequent hospitalizations for ACS (15% vs. 3%; p = 0.010). Multiple (> 2) lead repositions attempts, the use of septography and stylet-driven leads were independent predictors of higher risk of PMI with peak HsTnT > fourfold the URL. CONCLUSIONS: PMI seems common among patients undergoing LBBAP and may be associated with an increased risk of clinical outcomes in case of more pronounced (peak HsTnT > fourfold the URL) myocardial damage occurring during the procedure.
- Klíčová slova
- High sensitivity troponin, Left bundle branch area pacing, Lumen less lead, Periprocedural myocardial injury, Septography, Stylet-driven lead,
- MeSH
- blokáda Tawarova raménka MeSH
- kardiostimulace umělá MeSH
- lidé středního věku MeSH
- lidé MeSH
- poranění srdce etiologie MeSH
- senioři MeSH
- troponin T * krev MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- troponin T * MeSH
- MeSH
- blokáda Tawarova raménka etiologie terapie MeSH
- elektrokardiografie MeSH
- funkce levé komory srdeční MeSH
- Hisův svazek * MeSH
- kardiomyopatie * etiologie terapie MeSH
- kardiostimulace umělá škodlivé účinky MeSH
- lidé MeSH
- srdeční komory MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Continuous deep septal pacing and signal recording during implantation of left bundle branch pacing (LBBP) lead enables to monitor beat-to-beat changes of electrocardiogram (ECG) and myocardial current of injury (COI) as the lead crosses the septum. OBJECTIVES: This study aimed to characterize patterns of continuous QRS, ST-T, and COI change for monitoring of the lead depth and instantaneous determination of the obtained capture type (LBBP vs left ventricular septal pacing [LVSP]). METHODS: The ECG and COI during lead implantation were scrutinized for sudden changes of V6 R-wave peak time, V1 initial and terminal R-wave amplitude, V3-V6 R-wave amplitude, repolarization pattern and S-wave amplitude in I, V5-V6, and COI drop. The sudden and gradual transition patterns were diagnosed depending on the presence or absence of the above beat-to-beat ECG phenomena, respectively. RESULTS: A total of 212 pacemaker recipients were analyzed; LBBP and LVSP were obtained in 77.4% and 22.6%, respectively. There were 4.7 ± 2.1 and 0.2 ± 0.6 beat-to-beat phenomena in LBBP and LVSP patients, respectively. The sudden transition pattern, recognized in 80.7%, had sensitivity and specificity for LBBP diagnosis of 98.8% and 81.2%, respectively. A sudden drop of COI (29.4 ± 8.5 mV to 12.8 ± 4.9 mV) was observed in 53.9% patients (LBBP was simultaneously obtained in 92.7%). CONCLUSIONS: Capture of left bundle branch during lead penetration is a beat-to-beat phenomenon. Two transseptal transition patterns were identified: 1) sudden, which is typical for obtaining LBBP; and 2) gradual, which is typical for obtaining LVSP. A sudden COI drop, a very observable phenomenon, also identified reaching the left subendocardial area.
- Klíčová slova
- continuous pacing, current of injury, left bundle branch pacing, left ventricular septal pacing, transseptal patterns,
- MeSH
- blokáda Tawarova raménka patofyziologie terapie MeSH
- elektrokardiografie * MeSH
- Hisův svazek patofyziologie MeSH
- kardiostimulace umělá metody MeSH
- kardiostimulátor MeSH
- lidé středního věku MeSH
- lidé MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- srdeční septum patofyziologie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
From precordial ECG leads, the conventional determination of the negative derivative of the QRS complex (ND-ECG) assesses epicardial activation. Recently we showed that ultra-high-frequency electrocardiography (UHF-ECG) determines the activation of a larger volume of the ventricular wall. We aimed to combine these two methods to investigate the potential of volumetric and epicardial ventricular activation assessment and thereby determine the transmural activation sequence. We retrospectively analyzed 390 ECG records divided into three groups-healthy subjects with normal ECG, left bundle branch block (LBBB), and right bundle branch block (RBBB) patients. Then we created UHF-ECG and ND-ECG-derived depolarization maps and computed interventricular electrical dyssynchrony. Characteristic spatio-temporal differences were found between the volumetric UHF-ECG activation patterns and epicardial ND-ECG in the Normal, LBBB, and RBBB groups, despite the overall high correlations between both methods. Interventricular electrical dyssynchrony values assessed by the ND-ECG were consistently larger than values computed by the UHF-ECG method. Noninvasively obtained UHF-ECG and ND-ECG analyses describe different ventricular dyssynchrony and the general course of ventricular depolarization. Combining both methods based on standard 12-lead ECG electrode positions allows for a more detailed analysis of volumetric and epicardial ventricular electrical activation, including the assessment of the depolarization wave direction propagation in ventricles.
BACKGROUND AND AIMS: Right bundle branch block (RBBB) and resulting right ventricular (RV) electromechanical discoordination are thought to play a role in the disease process of subpulmonary RV dysfunction that frequently occur post-repair tetralogy of Fallot (ToF). We sought to describe this disease entity, the role of pulmonary re-valvulation, and the potential added value of RV cardiac resynchronization therapy (RV-CRT). METHODS: Two patients with repaired ToF, complete RBBB, pulmonary regurgitation, and significantly decreased RV function underwent echocardiography, cardiac magnetic resonance, and an invasive study to evaluate the potential for RV-CRT as part of the management strategy. The data were used to personalize the CircAdapt model of the human heart and circulation. Resulting Digital Twins were analysed to quantify the relative effects of RV pressure and volume overload and to predict the effect of RV-CRT. RESULTS: Echocardiography showed components of a classic RV dyssynchrony pattern which could be reversed by RV-CRT during invasive study and resulted in acute improvement in RV systolic function. The Digital Twins confirmed a contribution of electromechanical RV dyssynchrony to RV dysfunction and suggested improvement of RV contraction efficiency after RV-CRT. The one patient who underwent successful permanent RV-CRT as part of the pulmonary re-valvulation procedure carried improvements that were in line with the predictions based on his Digital Twin. CONCLUSION: An integrative diagnostic approach to RV dysfunction, including the construction of Digital Twins may help to identify candidates for RV-CRT as part of the lifetime management of ToF and similar congenital heart lesions.
- Klíčová slova
- Cardiac resynchronization therapy, Digital Twin, Right bundle branch block, Right ventricular dysfunction, Tetralogy of Fallot,
- MeSH
- blokáda Tawarova raménka diagnostické zobrazování etiologie terapie MeSH
- dysfunkce pravé srdeční komory * diagnostické zobrazování etiologie terapie MeSH
- echokardiografie MeSH
- Fallotova tetralogie * diagnostické zobrazování chirurgie MeSH
- lidé MeSH
- počítačová simulace MeSH
- srdeční komory MeSH
- srdeční resynchronizační terapie * škodlivé účinky MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Cardiac resynchronization therapy (CRT) using biventricular pacing (BVP) has been associated with greater clinical improvement in women than men. Recently, left bundle branch area pacing (LBBAP) has been shown to be an alternative form of CRT. OBJECTIVES: The purpose of this study was to investigate sex-specific outcomes for death and heart failure events in a large, international, multicenter, cohort of patients undergoing CRT with BVP or LBBAP. METHODS: In this international study of 1,778 patients (575 female and 1203 male), sex-specific survival analysis was performed to compare the effect of LBBAP-CRT relative to BVP-CRT on the combined endpoint of death or heart failure hospitalization (HFH), and secondary endpoints of HFH only, and death alone. RESULTS: Female patients were more likely to have nonischemic cardiomyopathy and left bundle branch block (LBBB) and less likely to have hypertension, diabetes, or coronary artery disease than were male patients. Overall, female patients had a better result with LBBAP compared with BVP than did male patients, with a significant 36% reduction in death or HFH (HR: 0.64; 95% CI: 0.43 to 0.97; P = 0.03) and a significant 60% reduction in HFH alone (HR: 0.4; 95% CI: 0.24 to 0.69, P < 0.01). Women had a greater reduction in death or HFH among those with nonischemic cardiomyopathy (HR: 0.45 95% CI: 0.26 to 0.79; P < 0.01) and LBBB (HR: 0.49; 95% CI: 0.27 to 0.87; P < 0.01). Sex-specific echocardiographic outcomes were better in women than in men. CONCLUSIONS: Women obtained significantly greater reductions in the combined endpoint of death or HFH (primarily driven by reduction in HFH) with LBBAP compared with BVP among patients requiring CRT than did men.
- Klíčová slova
- biventricular pacing, cardiac resynchronization therapy, heart failure, left bundle branch area pacing, sex difference,
- MeSH
- blokáda Tawarova raménka MeSH
- kardiomyopatie * terapie MeSH
- lidé MeSH
- srdeční resynchronizační terapie * metody MeSH
- srdeční selhání * MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
The field of cardiac pacing has changed rapidly in the last several years. Since the initial description of His bundle pacing targeting the conduction system, recent advances in pacing the left bundle branch and its fascicles have evolved. The field and investigators' knowledge of conduction system pacing including relevant anatomy and physiology has advanced significantly. The aim of this review is to provide a comprehensive update on recent advances in conduction system pacing.
- Klíčová slova
- His bundle pacing, cardiac resynchronization therapy, clinical trials, conduction system pacing, left bundle branch pacing,
- MeSH
- blokáda Tawarova raménka terapie MeSH
- elektrokardiografie MeSH
- Hisův svazek * MeSH
- lidé MeSH
- nemoci převodního systému srdečního terapie MeSH
- převodní systém srdeční MeSH
- srdeční resynchronizační terapie * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- Research Support, N.I.H., Extramural MeSH
- MeSH
- blokáda Tawarova raménka * diagnóza MeSH
- elektrokardiografie MeSH
- lidé MeSH
- převodní systém srdeční MeSH
- srdeční arytmie * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- dopisy MeSH
- práce podpořená grantem MeSH