Most cited article - PubMed ID 17881039
Quantification of t-tubule area and protein distribution in rat cardiac ventricular myocytes
The transverse-axial tubular system (tubular system) of cardiomyocytes plays a key role in excitation-contraction coupling. To determine the area of the tubular membrane in relation to the area of the surface membrane, indirect measurements through the determination of membrane capacitances are currently used in addition to microscopic methods. Unlike existing electrophysiological methods based on an irreversible procedure (osmotic shock), the proposed new approach uses a reversible short-term intermittent increase in the electrical resistance of the extracellular medium. The resulting increase in the lumen resistance of the tubular system makes it possible to determine separate capacitances of the tubular and surface membranes. Based on the analysis of the time course of the capacitive current, computational relations were derived to quantify the elements of the electrical equivalent circuit of the measured cardiomyocyte including both capacitances. The exposition to isotonic low-conductivity sucrose solution is reversible which is the main advantage of the proposed approach allowing repetitive measurements on the same cell under control and sucrose solutions. Experiments on rat ventricular cardiomyocytes (n = 20) resulted in the surface and tubular capacitance values implying the fraction of tubular capacitance/area of 0.327 ± 0.018. We conclude that the newly proposed method provides results comparable to the data obtained by the currently used detubulation method and, in addition, by being reversible, allows repeated evaluation of surface and tubular membrane parameters on the same cell.
- Keywords
- Cardiomyocyte, Novel method, Sucrose, Tubular membrane capacitance, Tubular system,
- MeSH
- Electric Conductivity MeSH
- Myocytes, Cardiac * MeSH
- Rats MeSH
- Osmotic Pressure MeSH
- Sucrose MeSH
- Excitation Contraction Coupling * MeSH
- Animals MeSH
- Check Tag
- Rats MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Names of Substances
- Sucrose MeSH
The transverse-axial tubular system (t-tubules) plays an essential role in excitation-contraction coupling in cardiomyocytes. Its remodelling is associated with various cardiac diseases. Numerous attempts were made to analyse characteristics essential for proper understanding of the t-tubules and their impact on cardiac cell function in health and disease. The currently available methodical approaches related to the fraction of the t-tubular membrane area produce diverse data. The widely used detubulation techniques cause irreversible cell impairment, thus, distinct cell samples have to be used for estimation of t-tubular parameters in untreated and detubulated cells. Our proposed alternative method is reversible and allows repetitive estimation of the fraction of t-tubular membrane (f t) in cardiomyocytes using short-term perfusion of the measured cell with a low-conductive isotonic sucrose solution. It results in a substantial increase in the electrical resistance of t-tubular lumen, thus, electrically separating the surface and t-tubular membranes. Using the whole-cell patch-clamp measurement and the new approach in enzymatically isolated rat atrial and ventricular myocytes, a set of data was measured and evaluated. The analysis of the electrical equivalent circuit resulted in the establishment of criteria for excluding measurements in which perfusion with a low conductivity solution did not affect the entire cell surface. As expected, the final average f t in ventricular myocytes (0.337 ± 0.017) was significantly higher than that in atrial myocytes (0.144 ± 0.015). The parameter f t could be estimated repetitively in a particular cell (0.345 ± 0.021 and 0.347 ± 0.023 in ventricular myocytes during the first and second sucrose perfusion, respectively). The new method is fast, simple, and leaves the measured cell intact. It can be applied in the course of experiments for which it is useful to estimate both the surface and t-tubular capacitance/area in a particular cell.
- Keywords
- detubulation, membrane capacitance, new method, rat cardiomyocytes, sucrose, t-tubules,
- Publication type
- Journal Article MeSH
The ratio of densities of Na-Ca exchanger current (INaCa) in the t-tubular and surface membranes (INaCa-ratio) computed from the values of INaCa and membrane capacitances (Cm) measured in adult rat ventricular cardiomyocytes before and after detubulation ranges between 1.7 and 25 (potentially even 40). Variations of action potential waveform and of calcium turnover within this span of the INaCa-ratio were simulated employing previously developed model of rat ventricular cell incorporating separate description of ion transport systems in the t-tubular and surface membranes. The increase of INaCa-ratio from 1.7 to 25 caused a prolongation of APD (duration of action potential at 90% repolarisation) by 12, 9, and 6% and an increase of peak intracellular Ca2+ transient by 45, 19, and 6% at 0.1, 1, and 5 Hz, respectively. The prolonged APD resulted from the increase of INaCa due to the exposure of a larger fraction of Na-Ca exchangers to higher Ca2+ transients under the t-tubular membrane. The accompanying rise of Ca2+ transient was a consequence of a higher Ca2+ load in sarcoplasmic reticulum induced by the increased Ca2+ cycling between the surface and t-tubular membranes. However, the reason for large differences in the INaCa-ratio assessed from measurements in adult rat cardiomyocytes remains to be explained.
- MeSH
- Cell Membrane metabolism MeSH
- Myocytes, Cardiac metabolism MeSH
- Rats MeSH
- Membrane Potentials physiology MeSH
- Models, Cardiovascular * MeSH
- Sodium metabolism MeSH
- Heart Ventricles metabolism MeSH
- Calcium metabolism MeSH
- Animals MeSH
- Check Tag
- Rats MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
- Names of Substances
- Sodium MeSH
- Calcium MeSH
The t-tubules of mammalian ventricular myocytes are invaginations of the surface membrane that form a complex network within the cell, with restricted diffusion to the bulk extracellular space. The trans-sarcolemmal flux of many ions, including Ca(2+), occurs predominantly across the t-tubule membrane and thus into and out of this restricted diffusion space. It seems possible, therefore, that ion concentration changes may occur in the t-tubule lumen, which would alter ion flux across the t-tubule membrane. We have used a computer model of the ventricular myocyte, incorporating a t-tubule compartment and experimentally determined values for diffusion between the t-tubule lumen and bulk extracellular space, and ion fluxes across the t-tubule membrane, to investigate this possibility. The results show that influx and efflux of different ion species across the t-tubule membrane are similar, but not equal. Changes of ion concentration can therefore occur close to the t-tubular membrane, thereby altering trans-sarcolemmal ion flux and thus cell function, although such changes are reduced by diffusion to the bulk extracellular space. Slowing diffusion results in larger changes in luminal ion concentrations. These results provide a deeper understanding of the role of the t-tubules in normal cell function, and are a basis for understanding the changes that occur in heart failure as a result of changes in t-tubule structure and ion fluxes.
- MeSH
- Diffusion MeSH
- Ions analysis MeSH
- Myocytes, Cardiac cytology physiology MeSH
- Rats MeSH
- Membrane Potentials MeSH
- Models, Cardiovascular * MeSH
- Computer Simulation MeSH
- Sarcolemma physiology MeSH
- Sarcoplasmic Reticulum physiology MeSH
- Calcium analysis MeSH
- Computational Biology methods MeSH
- Animals MeSH
- Check Tag
- Rats MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Names of Substances
- Ions MeSH
- Calcium MeSH