Ventricular dyssynchrony assessment using ultra-high frequency ECG technique
From precordial ECG leads, the conventional determination of the negative derivative of the QRS complex (ND-ECG) assesses epicardial activation. Recently we showed that ultra-high-frequency electrocardiography (UHF-ECG) determines the activation of a larger volume of the ventricular wall. We aimed to combine these two methods to investigate the potential of volumetric and epicardial ventricular activation assessment and thereby determine the transmural activation sequence. We retrospectively analyzed 390 ECG records divided into three groups-healthy subjects with normal ECG, left bundle branch block (LBBB), and right bundle branch block (RBBB) patients. Then we created UHF-ECG and ND-ECG-derived depolarization maps and computed interventricular electrical dyssynchrony. Characteristic spatio-temporal differences were found between the volumetric UHF-ECG activation patterns and epicardial ND-ECG in the Normal, LBBB, and RBBB groups, despite the overall high correlations between both methods. Interventricular electrical dyssynchrony values assessed by the ND-ECG were consistently larger than values computed by the UHF-ECG method. Noninvasively obtained UHF-ECG and ND-ECG analyses describe different ventricular dyssynchrony and the general course of ventricular depolarization. Combining both methods based on standard 12-lead ECG electrode positions allows for a more detailed analysis of volumetric and epicardial ventricular electrical activation, including the assessment of the depolarization wave direction propagation in ventricles.
- MeSH
- Bundle-Branch Block diagnosis MeSH
- Electrocardiography * methods MeSH
- Humans MeSH
- Retrospective Studies MeSH
- Arrhythmias, Cardiac MeSH
- Heart Ventricles * diagnostic imaging MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
Identifying electrical dyssynchrony is crucial for cardiac pacing and cardiac resynchronization therapy (CRT). The ultra-high-frequency electrocardiography (UHF-ECG) technique allows instantaneous dyssynchrony analyses with real-time visualization. This review explores the physiological background of higher frequencies in ventricular conduction and the translational evolution of UHF-ECG in cardiac pacing and CRT. Although high-frequency components were studied half a century ago, their exploration in the dyssynchrony context is rare. UHF-ECG records ECG signals from eight precordial leads over multiple beats in time. After initial conceptual studies, the implementation of an instant visualization of ventricular activation led to clinical implementation with minimal patient burden. UHF-ECG aids patient selection in biventricular CRT and evaluates ventricular activation during various forms of conduction system pacing (CSP). UHF-ECG ventricular electrical dyssynchrony has been associated with clinical outcomes in a large retrospective CRT cohort and has been used to study the electrophysiological differences between CSP methods, including His bundle pacing, left bundle branch (area) pacing, left ventricular septal pacing and conventional biventricular pacing. UHF-ECG can potentially be used to determine a tailored resynchronization approach (CRT through biventricular pacing or CSP) based on the electrical substrate (true LBBB vs. non-specified intraventricular conduction delay with more distal left ventricular conduction disease), for the optimization of CRT and holds promise beyond CRT for the risk stratification of ventricular arrhythmias.
- Keywords
- cardiac resynchronization therapy, conduction system pacing, electrical dyssynchrony, electrocardiography, ultra-high frequency,
- Publication type
- Journal Article MeSH
- Review MeSH
The study introduces and validates a novel high-frequency (100-400 Hz bandwidth, 2 kHz sampling frequency) electrocardiographic imaging (HFECGI) technique that measures intramural ventricular electrical activation. Ex-vivo experiments and clinical measurements were employed. Ex-vivo, two pig hearts were suspended in a human-torso shaped tank using surface tank electrodes, epicardial electrode sock, and plunge electrodes. We compared conventional epicardial electrocardiographic imaging (ECGI) with intramural activation by HFECGI and verified with sock and plunge electrodes. Clinical importance of HFECGI measurements was performed on 14 patients with variable conduction abnormalities. From 3 × 4 needle and 108 sock electrodes, 256 torso or 184 body surface electrodes records, transmural activation times, sock epicardial activation times, ECGI-derived activation times, and high-frequency activation times were computed. The ex-vivo transmural measurements showed that HFECGI measures intramural electrical activation, and ECGI-HFECGI activation times differences indicate endo-to-epi or epi-to-endo conduction direction. HFECGI-derived volumetric dyssynchrony was significantly lower than epicardial ECGI dyssynchrony. HFECGI dyssynchrony was able to distinguish between intraventricular conduction disturbance and bundle branch block patients.
- MeSH
- Diagnostic Imaging * MeSH
- Electrocardiography * MeSH
- Humans MeSH
- Swine MeSH
- Heart Conduction System * diagnostic imaging physiopathology MeSH
- Heart Ventricles * diagnostic imaging physiopathology MeSH
- Animals MeSH
- Check Tag
- Humans MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
Compression of ECG signal is essential especially in the area of signal transmission in telemedicine. There exist many compression algorithms which are described in various details, tested on various datasets and their performance is expressed by different ways. There is a lack of standardization in this area. This study points out these drawbacks and presents new compression algorithm which is properly described, tested and objectively compared with other authors. This study serves as an example how the standardization should look like. Single-cycle fractal-based (SCyF) compression algorithm is introduced and tested on 4 different databases-CSE database, MIT-BIH arrhythmia database, High-frequency signal and Brno University of Technology ECG quality database (BUT QDB). SCyF algorithm is always compared with well-known algorithm based on wavelet transform and set partitioning in hierarchical trees in terms of efficiency (2 methods) and quality/distortion of the signal after compression (12 methods). Detail analysis of the results is provided. The results of SCyF compression algorithm reach up to avL = 0.4460 bps and PRDN = 2.8236%.
- MeSH
- Algorithms * MeSH
- Databases, Factual * MeSH
- Electrocardiography methods MeSH
- Fractals * MeSH
- Data Compression methods MeSH
- Humans MeSH
- Signal Processing, Computer-Assisted MeSH
- Arrhythmias, Cardiac physiopathology MeSH
- Wavelet Analysis MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
This study investigates the impact of reduced transmural conduction velocity (TCV) on output parameters of the human heart. In a healthy heart, the TCV contributes to synchronization of the onset of contraction in individual layers of the left ventricle (LV). However, it is unclear whether the clinically observed decrease of TCV contributes significantly to a reduction of LV contractility. The applied three-dimensional finite element model of isovolumic contraction of the human LV incorporates transmural gradients in electromechanical delay and myocyte shortening velocity and evaluates the impact of TCV reduction on pressure rise (namely, (dP/dt)max) and on isovolumic contraction duration (IVCD) in a healthy LV. The model outputs are further exploited in the lumped "Windkessel" model of the human cardiovascular system (based on electrohydrodynamic analogy of respective differential equations) to simulate the impact of changes of (dP/dt)max and IVCD on chosen systemic parameters (ejection fraction, LV power, cardiac output, and blood pressure). The simulations have shown that a 50% decrease in TCV prolongs substantially the isovolumic contraction, decelerates slightly the LV pressure rise, increases the LV energy consumption, and reduces the LV power. These negative effects increase progressively with further reduction of TCV. In conclusion, these results suggest that the pumping efficacy of the human LV decreases with lower TCV due to a higher energy consumption and lower LV power. Although the changes induced by the clinically relevant reduction of TCV are not critical for a healthy heart, they may represent an important factor limiting the heart function under disease conditions.
- MeSH
- Atrial Fibrillation physiopathology MeSH
- Hemodynamics physiology MeSH
- Humans MeSH
- Models, Cardiovascular * MeSH
- Computer Simulation * MeSH
- Heart Conduction System physiology MeSH
- Ventricular Function physiology MeSH
- Heart Ventricles physiopathology MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
INTRODUCTION: Cardiac resynchronization therapy (CRT) is an effective treatment that reduces mortality and improves cardiac function in patients with left bundle branch block (LBBB). However, about 30% of patients passing the current criteria do not benefit or benefit only a little from CRT. Three predictors of benefit based on different ECG properties were compared: 1) "strict" left bundle branch block classification (SLBBB); 2) QRS area; 3) ventricular electrical delay (VED) which defines the septal-lateral conduction delay. These predictors have never been analyzed concurrently. We analyzed the relationship between them on a subset of 602 records from the MADIT-CRT trial. METHODS & RESULTS: SLBBB classification was performed by two experts; QRS area and VED were computed fully automatically. High-frequency QRS (HFQRS) maps were used to inspect conduction abnormalities. The correlation between SLBBB and other predictors was R = 0.613, 0.523 and 0.390 for VED, QRS area in Z lead, and QRS duration, respectively. Scatter plots were used to pick up disagreement between the predictors. The majority of SLBBB subjects- 295 of 330 (89%)-are supposed to respond positively to CRT according to the VED and QRS area, though 93 of 272 (34%) non-SLBBB should also benefit from CRT according to the VED and QRS area. CONCLUSION: SLBBB classification is limited by the proper setting of cut-off values. In addition, it is too "strict" and excludes patients that may benefit from CRT therapy. QRS area and VED are clearly defined parameters. They may be used to optimize biventricular stimulation. Detailed analysis of conduction irregularities with CRT optimization should be based on HFQRS maps.
- MeSH
- Action Potentials MeSH
- Bundle-Branch Block physiopathology therapy MeSH
- Electric Countershock MeSH
- Electrocardiography methods standards MeSH
- Ventricular Function, Left MeSH
- Humans MeSH
- Predictive Value of Tests MeSH
- Cardiac Resynchronization Therapy Devices standards MeSH
- Heart Rate MeSH
- Cardiac Resynchronization Therapy methods MeSH
- Treatment Outcome MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH