Distance-based detection
Dotaz
Zobrazit nápovědu
Chloride (Cl-) is an inorganic anion present in a broad range of samples (e.g. biological, environmental, food, water, etc.), the determination of which is of widespread significance. In this work, we translate the well-established traditional argentometric method (Mohr's precipitation titration) into a small, simple, portable, and low-cost paper-based microfluidic diagnostic device, which provides rapid and quantitative analysis. The developed device enables the determination of chloride sample volumes as small as 5 μL. A distance-based detection method is implemented providing fully instrument-free quantitation. The beneficial effects of channel geometry (variable widths with constant heights) on analytical parameters were investigated. Trapezoidal channels (channel width changes linearly with height) were used to create a gradient of paper surface (titrant) available for the reaction, compared to the typical uniform rectangular channels (constant channel width). The trapezoid with increasing width offered higher sensitivity and lower detection limits (i.e. 0.05 mM vs 0.1 mM from the rectangular channel) for chloride determination across the concentration range of 0.05-25 mM. In addition, the effect of concentration of the deposited reagent on the obtained distance signals was investigated using varying concentrations of titrant (AgNO3), which allowed determination of chloride across a wider dynamic range (up to 200 mM). The utility of the paper devices was demonstrated by determination of chloride in a variety of matrices including body fluids (sweat, serum, and urine) and water samples (drinking, mineral, river water).
- Klíčová slova
- Argentometric determination, Asymmetric trapezoidal microfluidic channels, Chloride determination, Distance-based measurement, Microfluidic paper-based analytical device,
- MeSH
- chloridy analýza MeSH
- lidé MeSH
- mikrofluidní analytické techniky * MeSH
- papír * MeSH
- povrchové vlastnosti MeSH
- tělesné tekutiny chemie MeSH
- voda chemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- chloridy MeSH
- voda MeSH
This work presents an affordable distance-based microfluidic paper-based device (μPAD), using polydiacetylene (PDA) liposome as a chromogenic substance with a smartphone-based photo editor, for rapid and in-field analysis of quaternary ammonium compounds (QACs) (e.g., didecyldimethylammonium chloride (DDAC), benzyldimethyltetradecyl ammonium chloride (BAC), and cetylpyridinium chloride (CPC)). In-field analysis of these compounds is important to ensure their antimicrobial activity and user safety since they are widely utilized as disinfectants in households and hospitals. The μPAD featured a thermometer-like shape consisting of a sample reservoir and a microchannel as the detection zone, which was pre-deposited with PDA liposome. The color change from blue to red appeared in the presence of QACs and the color bar lengths were proportional to the QAC concentrations. Reactions of QACs with the PDA required a specific pH range (from pH 4.0 to 10.0) and a readout time of 7 min. Analytical performance characteristics of the device were tested with DDAC, BAC, and CPC showing acceptable specificity, accuracy (96.1-109.4%), and precision (%RSDs ≤ 9.3%). Limits of detection and quantitation were in the ranges of 20 to 80 and 70 to 250 μM, respectively. Feasibility of the newly developed device was demonstrated for in-field analysis of QACs in fumigation solution providing comparable results with those obtained from a colorimetric assay (P > 0.05). The proposed device shows potentials for further applications of other analytes since it offers speed, simplicity, and affordability for in-field analysis, especially in remote areas where expertise, resources, and infrastructures are limited. Graphical abstract.
- Klíčová slova
- Distance-based microfluidic paper-based device, In-field analysis, Polydiacetylene, Quaternary ammonium compounds,
- Publikační typ
- časopisecké články MeSH
During the covid-19 pandemic, schools at all levels were often closed and online distance instruction (ODI) was applied. The main objective of this research was to discover the main didactic features of online distance instruction; and based on the collected data to define didactic recommendations towards improving the quality of the process. Five hypotheses were set that evaluated students' opinions in the areas of teachers' support for learners within ODI, types of sources exploited within ODI, means used for practising and fixing new knowledge within ODI, assessment of learners' performance within ODI, and students' feedback on ODI. In total, 272 respondents from upper secondary and higher education institutions participated in the research. Each respondent described the process of online distance instruction in two courses they selected of 64: (1) in a course that they appreciated, liked, enjoyed, and considered efficient from the point of view of their learning; (2) in a course that caused them discomfort in learning, as it was conducted in a way that did not suit them, and their learning did not bring the expected learning outcomes. Data were collected via a questionnaire; Chí-square test, adjusted residuals, and t test for comparison of means were calculated. Before the research started, teachers were trained in online distance instruction. Therefore, we expected that they will be competent in designing online distance courses and the courses will follow didactic principles. The results discovered significant differences in the frequency of occurrence of observed features in courses that received positive feedback compared to those having negative evaluation. However, some exceptions were detected.
- Klíčová slova
- COVID-19 pandemic, Didactic recommendations, Higher education, Online distance instruction, Students’ feedback, Upper secondary school,
- Publikační typ
- časopisecké články MeSH
Distance-based detection (DbD) on paper-based microfluidic analytical devices (μPADs) has emerged as a promising, cost-effective, simple, and instrumentation-free assay method. Broadening the applicability of a new way of immobilization of reagent for DbD on μPADs (DμPADs) is presented, employing an ion exchange (IE) interaction of an anionic metallochromic reagent, 2-(5-bromo-2-pyridylazo)-5-[N-n-propyl-N-(3-sulfopropyl)amino]phenol (5-Br-PAPS), on the anion-exchange filter paper. The IE DμPADs demonstrate superiority over standard cellulose filter paper in terms of the degree of reagent immobilization, detection sensitivity, and clear detection endpoints due to the strong retention of 5-Br-PAPS. The study investigated various parameters influencing DbD, including 5-Br-PAPS concentrations (0.25-1 mM), buffer types (acetic acid-Tris, MES), buffer concentrations (20-500 mM), and auxiliary complexing agents (acetic, formic, and glycolic acids). Subsequently, the performance of 17 metals (Ag+, Cd2+, Co2+, Cr3+, Cu2+, Fe2+, Hg2+, La2+, Mn2+, Ni2+, Pb2+, Ti2+, Zn2+, Al3+, As3+, Fe3+, and V4+) was evaluated, with color formation observed for 12 metals. Additionally, the paper surface was examined using SEM and SEM-EDX to verify the suitability of certain areas in the detection channel for reagent immobilization and metal binding. This method demonstrates quantitation limits of metals in the low μg mL-1 range, showing great potential for the rapid screening of toxic metals commonly found in herbal supplements and cosmetics regulated by the Food and Drug Administration (FDA). Thus, it holds promise for enhancing safety and regulatory compliance in product quality assessment. Furthermore, this method offers a cost-effective, environmentally sustainable, and user-friendly approach for the rapid visual quantification of heavy metals for in-field analysis, eliminating the need for complex instrumentation.
- Publikační typ
- časopisecké články MeSH
A surface plasmon resonance (SPR) phenomenon implemented via D-shaped polymer optical fiber (POF) is exploited to realize cortisol biosensors. In this work, two immonosensors are designed and developed for the qualitative as well as quantitative measurement of cortisol in artificial and real samples. The performances of the POF-based biosensors in cortisol recognition are achieved using different functionalization protocols to make the same antibody receptor layer over the SPR surface via cysteamine and lipoic acid, achieving a limit of detection (LOD) of 0.8 pg/mL and 0.2 pg/mL, respectively. More specifically, the use of cysteamine or lipoic acid changes the distance between the receptor layer and the SPR surface, improving the sensitivity at low concentrations of about one order of magnitude in the configuration based on lipoic acid. The LODs of both cortisol biosensors are achieved well competitively with other sensor systems but without the need for amplification or sample treatments. In order to obtain the selectivity tests, cholesterol and testosterone were used as interfering substances. Moreover, tests in simulated seawater were performed for the same cortisol concentration range achieved in buffer solution to assess the immunosensor response to the complex matrix. Finally, the developed cortisol biosensor was used in a real seawater sample to estimate the cortisol concentration value. The gold standard method has confirmed the estimated cortisol concentration value in real seawater samples. Liquid-liquid extraction was implemented to maximize the response of cortisol in liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) analysis.
- MeSH
- biosenzitivní techniky * metody MeSH
- hydrokortison * analýza MeSH
- limita detekce MeSH
- mořská voda * analýza MeSH
- optická vlákna MeSH
- polymery chemie MeSH
- povrchová plasmonová rezonance * metody MeSH
- vodní hospodářství * metody MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- hydrokortison * MeSH
- polymery MeSH
The deposition of chemical reagent inks on paper is a crucial step in the development and fabrication of microfluidic paper-based analytical devices (μPADs). A pen-plotting approach, delivering chemical ink deposition using technical pens filled with reagents and inserted into a desktop electronic plotter, is shown herein to be a versatile, low-cost, simple, rapid, reproducible, and high-throughput solution. The volume of the deposited ink was quantified gravimetrically, confirming that nanoliter volumes of reagents can be deposited reproducibly (e.g. 7.55 ± 0.37 nL/mm for a plotting speed of 10 cm/s) in detection zones of μPADs, typically spatially defined using wax printing. This approach was further investigated with regard to deposition of reagents in different geometrical forms (circular and linear), so demonstrating its applicability for preparation of μPADs with flexible design and application. By adjusting the plotting speed for linear deposition, lines with a relatively large range of widths (≈628-1192 μm) were created. Circular deposition was also demonstrated via delivery of reagents within wax printed circular fluidic barriers of a range of diameters (inner diameter = 1.5-7 mm). These capabilities were practically demonstrated via the fabrication of μPADs, based upon differing detection principles for determination of aluminum in natural waters using Morin as the fluorescent reagent. Traditional μPADs based on digital image colorimetry (DIC) were produced using circular deposition, whilst distance-based μPADs exploited linear deposition. Both types of μPADs developed using this method showed excellent precision for determination of trace concentrations of aluminium (average RSDs = 3.38% and 6.45%, and LODs = 0.5 ng (0.25 ppm) and 2 ng (0.5 ppm), for traditional and distance-based detection, respectively).
- Klíčová slova
- Aluminium determination, Distance-based detection, Microfluidic paper-based analytical device, Plotter, Reagent deposition, Technical pen,
- Publikační typ
- časopisecké články MeSH
The fight against unmanned vehicles is nothing new; however, especially with the arrival of new technologies that are easily accessible for the wider population, new problems are arising. The deployment of small unmanned aerial vehicles (UAVs) by paramilitary organizations during conflicts around the world has become a reality, non-lethal "paparazzi" actions have become a common practice, and it is only a matter of time until the population faces lethal attacks. The basic prerequisite for direct defense against attacking UAVs is their detection. The authors of this paper analysed the possibility of detecting flying aircraft in several different electro-magnetic spectrum bands. Firstly, methods based on calculations and simulations were chosen, and experiments in laboratories and measurements of the exterior were subsequently performed. As a result, values of the radar cross section (RCS), the noise level, the surface temperature, and optical as well as acoustic traces of tested devices were quantified. The outputs obtained from calculated, simulated, and experimentally detected values were found via UAV detection distances using specific sensors working in corresponding parts of the frequency spectrum.
- Klíčová slova
- air defense, air threat, detection, drone, reconnaissance, terrorism, unmanned aerial vehicle,
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Statistical analysis, which has become an integral part of evidence-based medicine, relies heavily on data quality that is of critical importance in modern clinical research. Input data are not only at risk of being falsified or fabricated, but also at risk of being mishandled by investigators. OBJECTIVE: The urgent need to assure the highest data quality possible has led to the implementation of various auditing strategies designed to monitor clinical trials and detect errors of different origin that frequently occur in the field. The objective of this study was to describe a machine learning-based algorithm to detect anomalous patterns in data created as a consequence of carelessness, systematic error, or intentionally by entering fabricated values. METHODS: A particular electronic data capture (EDC) system, which is used for data management in clinical registries, is presented including its architecture and data structure. This EDC system features an algorithm based on machine learning designed to detect anomalous patterns in quantitative data. The detection algorithm combines clustering with a series of 7 distance metrics that serve to determine the strength of an anomaly. For the detection process, the thresholds and combinations of the metrics were used and the detection performance was evaluated and validated in the experiments involving simulated anomalous data and real-world data. RESULTS: Five different clinical registries related to neuroscience were presented-all of them running in the given EDC system. Two of the registries were selected for the evaluation experiments and served also to validate the detection performance on an independent data set. The best performing combination of the distance metrics was that of Canberra, Manhattan, and Mahalanobis, whereas Cosine and Chebyshev metrics had been excluded from further analysis due to the lowest performance when used as single distance metric-based classifiers. CONCLUSIONS: The experimental results demonstrate that the algorithm is universal in nature, and as such may be implemented in other EDC systems, and is capable of anomalous data detection with a sensitivity exceeding 85%.
- Klíčová slova
- EDC system, anomaly detection, clinical research data, data quality, real-world evidence, registry database,
- Publikační typ
- časopisecké články MeSH
The purpose of this study is (1) to introduce a new approach for edge detection in orthopantograms (OPGs) and an improved automatic parameter selector for common edge detectors, (2) to present a comparison between our novel approach with common edge detectors and (3) to provide faster outputs without compromising quality. A new approach for edge detection based on statistical measures was introduced: (1) a set of N edge detection results is calculated from a given input image and a selected type of edge detector, (2) N correspondence maps are constructed from N edge detection results, (3) probabilities and average probabilities are computed, (4) an overall correspondence is evaluated for each correspondence map and (5) the correspondence map providing the best overall correspondence is taken as the result of edge detection procedure. A comparison with common edge detectors (the Roberts, Prewitt, Sobel, Laplacian of the Gaussian and Canny methods) with various parameter settings (304 combinations for each test image) was carried out. The methods were assessed objectively [edge mismatch error (EME), modified Hausdorff distance (MHD) and principal component analysis] and subjectively by experts in dentistry and based on time demands. The suitability of the new approach for edge detection in OPGs was confirmed by experts. The current conventional methods in edge detection in OPGs are inadequate (none of the tested methods reach an EME value or MHD value below 0.1). Our proposed approach for edge detection shows promising potential for its implementation in clinical dentistry. It enhances the accuracy of OPG interpretation and advances diagnosis and treatment planning.
- Klíčová slova
- computer-assisted image processing, medical imaging, panoramic radiography,
- MeSH
- algoritmy MeSH
- analýza hlavních komponent MeSH
- anatomická značka diagnostické zobrazování MeSH
- artefakty MeSH
- časové faktory MeSH
- cysty čelistí diagnostické zobrazování MeSH
- extrakce zubů MeSH
- lidé MeSH
- normální rozdělení MeSH
- počítačové zpracování obrazu statistika a číselné údaje MeSH
- pravděpodobnost MeSH
- rentgendiagnostika panoramatická statistika a číselné údaje MeSH
- rentgenový obraz - interpretace počítačová metody MeSH
- zubní kaz diagnostické zobrazování MeSH
- zuby přespočetné diagnostické zobrazování MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
Herein, we describe an ultrasensitive specific biosensing system for detection of sarcosine as a potential biomarker of prostate carcinoma based on Förster resonance energy transfer (FRET). The FRET biosensor employs anti-sarcosine antibodies immobilized on paramagnetic nanoparticles surface for specific antigen binding. Successful binding of sarcosine leads to assembly of a sandwich construct composed of anti-sarcosine antibodies keeping the Förster distance (Ro) of FRET pair in required proximity. The detection is based on spectral overlap between gold-functionalized green fluorescent protein and antibodies@quantum dots bioconjugate (λex 400 nm). The saturation curve of sarcosine based on FRET efficiency (F₆₀₄/F₅₁₀ ratio) was tested within linear dynamic range from 5 to 50 nM with detection limit down to 50 pM. Assembled biosensor was then successfully employed for sarcosine quantification in prostatic cell lines (PC3, 22Rv1, PNT1A), and urinary samples of prostate adenocarcinoma patients.
- MeSH
- dextrany chemie ultrastruktura MeSH
- lidé MeSH
- magnetické nanočástice chemie ultrastruktura MeSH
- molekulární zobrazování metody MeSH
- monoklonální protilátky chemie imunologie MeSH
- nádorové biomarkery analýza MeSH
- nádorové buněčné linie MeSH
- nádory prostaty chemie diagnóza imunologie MeSH
- nanokapsle chemie ultrastruktura MeSH
- reprodukovatelnost výsledků MeSH
- rezonanční přenos fluorescenční energie metody MeSH
- sarkosin analýza imunologie MeSH
- senzitivita a specificita MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- dextrany MeSH
- ferumoxtran-10 MeSH Prohlížeč
- magnetické nanočástice MeSH
- monoklonální protilátky MeSH
- nádorové biomarkery MeSH
- nanokapsle MeSH
- sarkosin MeSH