• Je něco špatně v tomto záznamu ?

Hemodynamic outcomes of geometric ring annuloplasty for aortic valve repair: a 4-center pilot trial

D. Mazzitelli, C. Stamm, JS. Rankin, C. Nöbauer, J. Pirk, B. Meuris, PS. Crooke, A. Wagner, LA. Beavan, CD. Griffin, D. Powers, B. Nasseri, C. Schreiber, R. Hetzer, R. Lange,

. 2014 ; 148 (1) : 168-75.

Jazyk angličtina Země Spojené státy americké

Typ dokumentu klinické zkoušky, časopisecké články, multicentrická studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc14074610

OBJECTIVES: A geometric annuloplasty ring could improve efficacy and stability of aortic valve repair. Toward this goal, a 1-piece 3-dimensional titanium annuloplasty ring with Dacron covering was developed and tested successfully in animals. The purpose of this study was to define hemodynamic outcomes with this device used as the annuloplasty component of human aortic valve repair. METHODS: In a 4-center pilot trial with informed consent, 16 patients underwent aortic valve repair for aortic insufficiency, with the annuloplasty device sutured into the annulus beneath the leaflets. Preoperative annular diameter averaged 26.5 ± 2.0 (mean ± standard deviation) mm, and average ring size was 22.3 ± 1.2 mm. After annuloplasty, leaflet defects were easy to identify, and 14 of 16 patients (88%) required leaflet plication and/or autologous pericardial reconstruction for leaflet defects. Three patients had ascending aortic replacement, and 2 had remodeling root replacement. One had ultrasonic leaflet decalcification and another tricuspid valve annuloplasty. Follow-up data were from site-specific studies at the 6-month postoperative time point. RESULTS: There were no in-hospital mortalities or major complications. Preoperative aortic insufficiency grade (0-4 scale) was 3.6 ± 1.0 and fell to 1.0 ± 0.8 at 6 months (P < .0001). New York Heart Association class fell from 2.5 ± 0.5 to 1.1 ± 0.3 (P < .0001). Postrepair valve area was 2.7 ± 0.2 cm(2), and 6-month mean systolic gradient was 11.3 ± 3.3 mm Hg. Left ventricular end-diastolic diameter and ejection fraction both normalized (both P < .0001). CONCLUSIONS: Geometric ring annuloplasty facilitated aortic valve repair, allowing more precise reconstruction of leaflet defects. Aortic insufficiency reduction and systolic gradients were excellent, and expansion of valve reconstruction into broader categories of aortic valve disease seems indicated.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc14074610
003      
CZ-PrNML
005      
20230315104721.0
007      
ta
008      
141006s2014 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jtcvs.2013.08.031 $2 doi
035    __
$a (PubMed)24113022
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Mazzitelli, Domenico $u German Heart Center Munich, Department of Cardiovascular Surgery, Technische Universität München, Munich, Germany.
245    10
$a Hemodynamic outcomes of geometric ring annuloplasty for aortic valve repair: a 4-center pilot trial / $c D. Mazzitelli, C. Stamm, JS. Rankin, C. Nöbauer, J. Pirk, B. Meuris, PS. Crooke, A. Wagner, LA. Beavan, CD. Griffin, D. Powers, B. Nasseri, C. Schreiber, R. Hetzer, R. Lange,
520    9_
$a OBJECTIVES: A geometric annuloplasty ring could improve efficacy and stability of aortic valve repair. Toward this goal, a 1-piece 3-dimensional titanium annuloplasty ring with Dacron covering was developed and tested successfully in animals. The purpose of this study was to define hemodynamic outcomes with this device used as the annuloplasty component of human aortic valve repair. METHODS: In a 4-center pilot trial with informed consent, 16 patients underwent aortic valve repair for aortic insufficiency, with the annuloplasty device sutured into the annulus beneath the leaflets. Preoperative annular diameter averaged 26.5 ± 2.0 (mean ± standard deviation) mm, and average ring size was 22.3 ± 1.2 mm. After annuloplasty, leaflet defects were easy to identify, and 14 of 16 patients (88%) required leaflet plication and/or autologous pericardial reconstruction for leaflet defects. Three patients had ascending aortic replacement, and 2 had remodeling root replacement. One had ultrasonic leaflet decalcification and another tricuspid valve annuloplasty. Follow-up data were from site-specific studies at the 6-month postoperative time point. RESULTS: There were no in-hospital mortalities or major complications. Preoperative aortic insufficiency grade (0-4 scale) was 3.6 ± 1.0 and fell to 1.0 ± 0.8 at 6 months (P < .0001). New York Heart Association class fell from 2.5 ± 0.5 to 1.1 ± 0.3 (P < .0001). Postrepair valve area was 2.7 ± 0.2 cm(2), and 6-month mean systolic gradient was 11.3 ± 3.3 mm Hg. Left ventricular end-diastolic diameter and ejection fraction both normalized (both P < .0001). CONCLUSIONS: Geometric ring annuloplasty facilitated aortic valve repair, allowing more precise reconstruction of leaflet defects. Aortic insufficiency reduction and systolic gradients were excellent, and expansion of valve reconstruction into broader categories of aortic valve disease seems indicated.
650    _2
$a senioři $7 D000368
650    _2
$a senioři nad 80 let $7 D000369
650    _2
$a aortální chlopeň $x patofyziologie $x chirurgie $x ultrasonografie $7 D001021
650    _2
$a aortální insuficience $x diagnóza $x patofyziologie $x chirurgie $7 D001022
650    _2
$a anuloplastika srdeční chlopně $x přístrojové vybavení $7 D058385
650    _2
$a barevná dopplerovská echokardiografie $7 D018618
650    _2
$a echokardiografie transezofageální $7 D017548
650    _2
$a ženské pohlaví $7 D005260
650    12
$a srdeční chlopně umělé $7 D006350
650    _2
$a chirurgická náhrada chlopně $x přístrojové vybavení $7 D019918
650    12
$a hemodynamika $7 D006439
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a pilotní projekty $7 D010865
650    _2
$a polyethylentereftaláty $7 D011093
650    _2
$a protézy - design $7 D011474
650    _2
$a obnova funkce $7 D020127
650    _2
$a stupeň závažnosti nemoci $7 D012720
650    _2
$a časové faktory $7 D013997
650    _2
$a titan $7 D014025
650    _2
$a výsledek terapie $7 D016896
651    _2
$a Evropa $7 D005060
655    _2
$a klinické zkoušky $7 D016430
655    _2
$a časopisecké články $7 D016428
655    _2
$a multicentrická studie $7 D016448
700    1_
$a Stamm, Christof $u German Heart Center Berlin, Berlin, Germany.
700    1_
$a Rankin, J Scott $u Vanderbilt University, Nashville, Tenn. Electronic address: jsrankinmd@cs.com.
700    1_
$a Nöbauer, Christian $u German Heart Center Munich, Department of Cardiovascular Surgery, Technische Universität München, Munich, Germany.
700    1_
$a Pirk, Jan $u Institute for Clinical and Experimental Medicine, Prague, Czech Republic.
700    1_
$a Meuris, Bart $u Department of Cardiovascular Diseases, Katholieke Universiteit Leuven, Leuven, Belgium.
700    1_
$a Crooke, Philip S $u Vanderbilt University, Nashville, Tenn.
700    1_
$a Wagner, Anke $u German Heart Center Munich, Department of Cardiovascular Surgery, Technische Universität München, Munich, Germany.
700    1_
$a Beavan, L Alan $u BioStable Science and Engineering Inc, Austin, Tex.
700    1_
$a Griffin, Charles D $u BioStable Science and Engineering Inc, Austin, Tex.
700    1_
$a Powers, Debby $u BioStable Science and Engineering Inc, Austin, Tex.
700    1_
$a Nasseri, Boris $u German Heart Center Berlin, Berlin, Germany.
700    1_
$a Schreiber, Christian $u German Heart Center Munich, Department of Cardiovascular Surgery, Technische Universität München, Munich, Germany.
700    1_
$a Hetzer, Roland, $u German Heart Center Berlin, Berlin, Germany. $d 1944- $7 xx0283447
700    1_
$a Lange, Rüdiger, $u German Heart Center Munich, Department of Cardiovascular Surgery, Technische Universität München, Munich, Germany. $d 1953- $7 xx0282824
773    0_
$w MED00003020 $t Journal of thoracic and cardiovascular surgery $x 1097-685X $g Roč. 148, č. 1 (2014), s. 168-75
856    41
$u https://pubmed.ncbi.nlm.nih.gov/24113022 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20141006 $b ABA008
991    __
$a 20230315104717 $b ABA008
999    __
$a ok $b bmc $g 1042493 $s 873522
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 148 $c 1 $d 168-75 $i 1097-685X $m Journal of thoracic and cardiovascular surgery $n J Thorac Cardiovasc Surg $x MED00003020
LZP    __
$a Pubmed-20141006

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...