-
Je něco špatně v tomto záznamu ?
Iron-based compounds coordinated with phospho-polymers as biocompatible probes for dual 31P/1H magnetic resonance imaging and spectroscopy
L. Kracíková, L. Androvič, D. Červený, N. Jirát-Ziółkowska, M. Babič, M. Švábová, D. Jirák, R. Laga
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články
Grantová podpora
271723
Grantová Agentura, Univerzita Karlova
NU20-08-00095
Ministerstvo Zdravotnictví Ceské Republiky
Programme EXCELES
National Institute for Research of Metabolic and Cardiovascular Diseases
LX22NPO5104
National Institute for Research of Metabolic and Cardiovascular Diseases
NLK
Directory of Open Access Journals
od 2011
Free Medical Journals
od 2011
PubMed Central
od 2011
Europe PubMed Central
od 2011
ProQuest Central
od 2021-01-01
Open Access Digital Library
od 2011-01-01
Open Access Digital Library
od 2011-01-01
Health & Medicine (ProQuest)
od 2021-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2011
Springer Nature OA/Free Journals
od 2011-12-01
Springer Nature - nature.com Journals - Fully Open Access
od 2011-12-01
- MeSH
- magnetická rezonanční spektroskopie MeSH
- magnetická rezonanční tomografie * metody MeSH
- polymery * MeSH
- tkáňová distribuce MeSH
- voda MeSH
- železo MeSH
- Publikační typ
- časopisecké články MeSH
In this work, we present the synthesis and evaluation of magnetic resonance (MR) properties of novel phosphorus/iron-containing probes for dual 31P and 1H MR imaging and spectroscopy (MRI and MRS). The presented probes are composed of biocompatible semitelechelic and multivalent phospho-polymers based on poly(2-methacryloyloxyethyl phosphorylcholine) (pMPC) coordinated with small paramagnetic Fe3+ ions or superparamagnetic maghemite (γ-Fe2O3) nanoparticles via deferoxamine group linked to the end or along the polymer chains. All probes provided very short 1H T1 and T2 relaxation times even at low iron concentrations. The presence of iron had a significant impact on the shortening of 31P relaxation, with the effect being more pronounced for probes based on γ-Fe2O3 and multivalent polymer. While the water-soluble probe having one Fe3+ ion per polymer chain was satisfactorily visualized by both 31P-MRS and 31P-MRI, the probe with multiple Fe3+ ions could only be detected by 31P-MRS, and the probes consisting of γ-Fe2O3 nanoparticles could not be imaged by either technique due to their ultra-short 31P relaxations. In this proof-of-principle study performed on phantoms at a clinically relevant magnetic fields, we demonstrated how the different forms and concentrations of iron affect both the 1H MR signal of the surrounding water molecules and the 31P MR signal of the phospho-polymer probe. Thus, this double contrast can be exploited to simultaneously visualize body anatomy and monitor probe biodistribution.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24007116
- 003
- CZ-PrNML
- 005
- 20240423155731.0
- 007
- ta
- 008
- 240412s2024 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1038/s41598-024-54158-x $2 doi
- 035 __
- $a (PubMed)38360883
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Kracíková, Lucie $u Institute of Macromolecular Chemistry, Czech Academy of Sciences, Heyrovského nám. 2, 162 00, Prague 6, Czech Republic $u Faculty of Chemical Technology, University of Chemistry and Technology, Prague, Technická 5, 166 28, Prague 6, Czech Republic
- 245 10
- $a Iron-based compounds coordinated with phospho-polymers as biocompatible probes for dual 31P/1H magnetic resonance imaging and spectroscopy / $c L. Kracíková, L. Androvič, D. Červený, N. Jirát-Ziółkowska, M. Babič, M. Švábová, D. Jirák, R. Laga
- 520 9_
- $a In this work, we present the synthesis and evaluation of magnetic resonance (MR) properties of novel phosphorus/iron-containing probes for dual 31P and 1H MR imaging and spectroscopy (MRI and MRS). The presented probes are composed of biocompatible semitelechelic and multivalent phospho-polymers based on poly(2-methacryloyloxyethyl phosphorylcholine) (pMPC) coordinated with small paramagnetic Fe3+ ions or superparamagnetic maghemite (γ-Fe2O3) nanoparticles via deferoxamine group linked to the end or along the polymer chains. All probes provided very short 1H T1 and T2 relaxation times even at low iron concentrations. The presence of iron had a significant impact on the shortening of 31P relaxation, with the effect being more pronounced for probes based on γ-Fe2O3 and multivalent polymer. While the water-soluble probe having one Fe3+ ion per polymer chain was satisfactorily visualized by both 31P-MRS and 31P-MRI, the probe with multiple Fe3+ ions could only be detected by 31P-MRS, and the probes consisting of γ-Fe2O3 nanoparticles could not be imaged by either technique due to their ultra-short 31P relaxations. In this proof-of-principle study performed on phantoms at a clinically relevant magnetic fields, we demonstrated how the different forms and concentrations of iron affect both the 1H MR signal of the surrounding water molecules and the 31P MR signal of the phospho-polymer probe. Thus, this double contrast can be exploited to simultaneously visualize body anatomy and monitor probe biodistribution.
- 650 12
- $a polymery $7 D011108
- 650 _2
- $a tkáňová distribuce $7 D014018
- 650 12
- $a magnetická rezonanční tomografie $x metody $7 D008279
- 650 _2
- $a magnetická rezonanční spektroskopie $7 D009682
- 650 _2
- $a železo $7 D007501
- 650 _2
- $a voda $7 D014867
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Androvič, Ladislav $u Institute of Macromolecular Chemistry, Czech Academy of Sciences, Heyrovského nám. 2, 162 00, Prague 6, Czech Republic
- 700 1_
- $a Červený, David $u Institute for Clinical and Experimental Medicine, Vídeňská 1958/9, 140 21, Prague 4, Czech Republic $u Institute of Biophysics and Informatics, First Faculty of Medicine, Charles University, Kateřinská 1660/32, 121 08, Prague, Czech Republic
- 700 1_
- $a Jirát-Ziółkowska, Natalia $u Institute for Clinical and Experimental Medicine, Vídeňská 1958/9, 140 21, Prague 4, Czech Republic $u Institute of Biophysics and Informatics, First Faculty of Medicine, Charles University, Kateřinská 1660/32, 121 08, Prague, Czech Republic
- 700 1_
- $a Babič, Michal $u Institute of Macromolecular Chemistry, Czech Academy of Sciences, Heyrovského nám. 2, 162 00, Prague 6, Czech Republic
- 700 1_
- $a Švábová, Monika $u Institute of Macromolecular Chemistry, Czech Academy of Sciences, Heyrovského nám. 2, 162 00, Prague 6, Czech Republic
- 700 1_
- $a Jirák, Daniel $u Institute for Clinical and Experimental Medicine, Vídeňská 1958/9, 140 21, Prague 4, Czech Republic. daniel.jirak@ikem.cz $u Faculty of Health Studies, Technical University of Liberec, Studentská 1402/2, 46117, Liberec, Czech Republic. daniel.jirak@ikem.cz
- 700 1_
- $a Laga, Richard $u Institute of Macromolecular Chemistry, Czech Academy of Sciences, Heyrovského nám. 2, 162 00, Prague 6, Czech Republic. laga@imc.cas.cz
- 773 0_
- $w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 14, č. 1 (2024), s. 3847
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/38360883 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20240412 $b ABA008
- 991 __
- $a 20240423155727 $b ABA008
- 999 __
- $a ok $b bmc $g 2081234 $s 1216883
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2024 $b 14 $c 1 $d 3847 $e 20240215 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
- GRA __
- $a 271723 $p Grantová Agentura, Univerzita Karlova
- GRA __
- $a NU20-08-00095 $p Ministerstvo Zdravotnictví Ceské Republiky
- GRA __
- $a Programme EXCELES $p National Institute for Research of Metabolic and Cardiovascular Diseases
- GRA __
- $a LX22NPO5104 $p National Institute for Research of Metabolic and Cardiovascular Diseases
- LZP __
- $a Pubmed-20240412