Low-fouling surface plasmon resonance biosensor for multi-step detection of foodborne bacterial pathogens in complex food samples
Jazyk angličtina Země Velká Británie, Anglie Médium print-electronic
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
26807521
DOI
10.1016/j.bios.2016.01.040
PII: S0956-5663(16)30040-9
Knihovny.cz E-zdroje
- Klíčová slova
- Detection of bacterial pathogens, E. coli O157:H7, Food safety, Gold nanoparticles, Low-fouling biorecognition coatings, Polymer brushes, Surface plasmon resonance biosensor,
- MeSH
- biosenzitivní techniky * MeSH
- Escherichia coli O157 izolace a purifikace patogenita MeSH
- imobilizační protilátky chemie MeSH
- kontaminace potravin MeSH
- lidé MeSH
- limita detekce MeSH
- nemoci přenášené potravou diagnóza mikrobiologie MeSH
- potravinářská mikrobiologie * MeSH
- povrchová plasmonová rezonance MeSH
- zlato chemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- imobilizační protilátky MeSH
- zlato MeSH
Recent outbreaks of foodborne illnesses have shown that foodborne bacterial pathogens present a significant threat to public health, resulting in an increased need for technologies capable of fast and reliable screening of food commodities. The optimal method of pathogen detection in foods should: (i) be rapid, specific, and sensitive; (ii) require minimum sample preparation; and (iii) be robust and cost-effective, thus enabling use in the field. Here we report the use of a SPR biosensor based on ultra-low fouling and functionalizable poly(carboxybetaine acrylamide) (pCBAA) brushes for the rapid and sensitive detection of bacterial pathogens in crude food samples utilizing a three-step detection assay. We studied both the surface resistance to fouling and the functional capabilities of these brushes with respect to each step of the assay, namely: (I) incubation of the sensor with crude food samples, resulting in the capture of bacteria by antibodies immobilized to the pCBAA coating, (II) binding of secondary biotinylated antibody (Ab2) to previously captured bacteria, and (III) binding of streptavidin-coated gold nanoparticles to the biotinylated Ab2 in order to enhance the sensor response. We also investigated the effects of the brush thickness on the biorecognition capabilities of the gold-grafted functionalized pCBAA coatings. We demonstrate that pCBAA-compared to standard low-fouling OEG-based alkanethiolate self-assemabled monolayers-exhibits superior surface resistance regarding both fouling from complex food samples as well as the non-specific binding of S-AuNPs. We further demonstrate that a SPR biosensor based on a pCBAA brush with a thickness as low as 20 nm was capable of detecting E. coli O157:H7 and Salmonella sp. in complex hamburger and cucumber samples with extraordinary sensitivity and specificity. The limits of detection for the two bacteria in cucumber and hamburger extracts were determined to be 57 CFU/mL and 17 CFU/mL for E. coli and 7.4 × 10(3) CFU/mL and 11.7 × 10(3)CFU/mL for Salmonella sp., respectively. In addition, we demonstrate the simultaneous detection of E. coli and Salmonella sp. in hamburger sample using a multichannel SPR biosensor having appropriate functional coatings.
Institute of Photonics and Electronics Czech Academy of Sciences Chaberská 57 Prague Czech Republic
Police of the Czech Republic Kapucínská 214 2 Prague Czech Republic
Citace poskytuje Crossref.org