Ablation of Atrial Fibrillation With Pulsed Electric Fields: An Ultra-Rapid, Tissue-Selective Modality for Cardiac Ablation
Language English Country United States Media print-electronic
Document type Journal Article, Research Support, Non-U.S. Gov't
PubMed
30139499
DOI
10.1016/j.jacep.2018.04.005
PII: S2405-500X(18)30366-9
Knihovny.cz E-resources
- Keywords
- atrial fibrillation, catheter ablation, electroporation, pulmonary vein isolation, pulsed electric field,
- MeSH
- Operative Time MeSH
- Electroporation methods MeSH
- Endocardium surgery MeSH
- Atrial Fibrillation surgery MeSH
- Catheter Ablation methods MeSH
- Middle Aged MeSH
- Humans MeSH
- Pericardium surgery MeSH
- Prospective Studies MeSH
- Aged MeSH
- Pulmonary Veins surgery MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
OBJECTIVES: The authors report the first acute clinical experience of atrial fibrillation ablation with PEF-both epicardial box lesions during cardiac surgery, and catheter-based PV isolation. BACKGROUND: Standard energy sources rely on time-dependent conductive heating/cooling and ablate all tissue types indiscriminately. Pulsed electric field (PEF) energy ablates nonthermally by creating nanoscale pores in cell membranes. Potential advantages for atrial fibrillation ablation include: 1) cardiomyocytes have among the lowest sensitivity of any tissue to PEF-allowing tissue selectivity, thereby minimizing ablation of nontarget collateral tissue; 2) PEF is delivered rapidly over a few seconds; and 3) the absence of coagulative necrosis obviates the risk of pulmonary vein (PV) stenosis. METHODS: PEF ablation was performed using a custom over-the-wire endocardial catheter for percutaneous transseptal PV isolation, and a linear catheter for encircling the PVs and posterior left atrium during concomitant cardiac surgery. Endocardial voltage maps were created pre- and post-ablation. Continuous and categorical data are summarized and presented as mean ± SD and frequencies. RESULTS: At 2 centers, 22 patients underwent ablation under general anesthesia: 15 endocardial and 7 epicardial. Catheter PV isolation was successful in all 57 PVs in 15 patients (100%) using 3.26 ± 0.5 lesions/PV: procedure time 67 ± 10.5 min, catheter time (PEF catheter entry to exit) 19 ± 2.5 min, total PEF energy delivery time <60 s/patient, and fluoroscopy time 12 ± 4.0 min. Surgical box lesions were successful in 6 of 7 patients (86%) using 2 lesions/patient. The catheter time for epicardial ablation was 50.7 ± 19.5 min. There were no complications. CONCLUSIONS: These data usher in a new era of tissue-specific, ultrarapid ablation of atrial fibrillation.
Department of Cardiac Surgery Homolka Hospital Prague Czech Republic
Department of Cardiology Homolka Hospital Prague Czech Republic
Department of Cardiothoracic Surgery Baylor Medical Center Dallas Texas
References provided by Crossref.org
Clinical Outcomes by Sex After Pulsed Field Ablation of Atrial Fibrillation
Pulsed Field Ablation Versus Radiofrequency Ablation: Esophageal Injury in a Novel Porcine Model
Use of Bipolar Radiofrequency Catheter Ablation in the Treatment of Cardiac Arrhythmias