- MeSH
- anastomóza chirurgická škodlivé účinky metody MeSH
- lidé MeSH
- močový měchýř chirurgie MeSH
- striktura uretry * chirurgie MeSH
- uretra * chirurgie MeSH
- urologické chirurgické výkony u mužů metody MeSH
- ústní sliznice * transplantace MeSH
- zákroky plastické chirurgie metody MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- komentáře MeSH
BACKGROUND: Accelerated partial breast irradiation (APBI) is an alternative breast-conserving therapy approach where radiation is delivered in less time compared to whole breast irradiation (WBI), resulting in improved patient convenience, less toxicity, and cost savings. This prospective randomized study compares the external beam APBI with commonly used moderate hypofractionated WBI in terms of feasibility, safety, tolerance, and cosmetic effects. METHODS: Early breast cancer patients after partial mastectomy were equally randomized into two arms- external APBI and moderate hypofractionated WBI. External beam technique using available technical innovations commonly used in targeted hypofractionated radiotherapy to minimize irradiated volumes was used (cone beam computed tomography navigation to clips in the tumor bed, deep inspiration breath hold technique, volumetric modulated arc therapy dose application, using flattening filter free beams and the six degrees of freedom robotic treatment couch). Cosmetics results and toxicity were evaluated using questionnaires, CTCAE criteria, and photo documentation. RESULTS: The analysis of 84 patients with a median age of 64 years showed significantly fewer acute adverse events in the APBI arm regarding skin reactions, local and general symptoms during a median follow-up of 37 months (range 21-45 months). A significant difference in favor of the APBI arm in grade ≥ 2 late skin toxicity was observed (p = 0.026). Late toxicity in the breast area (deformation, edema, fibrosis, and pain), affecting the quality of life and cosmetic effect, occurred in 61% and 17% of patients in WBI and APBI arms, respectively. The cosmetic effect was more favorable in the APBI arm, especially 6 to 12 months after the radiotherapy. CONCLUSION: External APBI demonstrated better feasibility and less toxicity than the standard regimen in the adjuvant setting for treating early breast cancer patients. The presented study confirmed the level of evidence for establishing the external APBI in daily clinical practice. TRIAL REGISTRATION: NCT06007118.
- MeSH
- kojenec MeSH
- kombinovaná terapie MeSH
- kvalita života MeSH
- lidé MeSH
- mastektomie MeSH
- nádory prsu * radioterapie chirurgie patologie MeSH
- předškolní dítě MeSH
- prospektivní studie MeSH
- segmentální mastektomie MeSH
- Check Tag
- kojenec MeSH
- lidé MeSH
- předškolní dítě MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
BACKGROUND: Targeted axillary dissection (TAD) is an established method for axillary staging in patients with breast cancer after neoadjuvant chemotherapy (NAC). TAD consists of sentinel lymph node biopsy and initially pathological lymph node excision, which must be marked by a reliable marker before NAC. METHODS: The IMTAD study is a prospective multicentre trial comparing three localisation markers for lymph node localisation (clip + iodine seed, magnetic seed, carbon suspension) facilitating subsequent surgical excision in the form of TAD. The primary outcome was to prospectively compare the reliability, accuracy, and safety according to complication rate during marker implantation and detection and marker dislodgement. RESULTS: One hundred eighty-nine patients were included in the study-in 135 patients clip + iodine seed was used, in 30 patients magnetic seed and in 24 patients carbon suspension. The complication rate during the marker implantation and detection were not statistically significant between individual markers (p = 0.263; p = 0.117). Marker dislodgement was reported in 4 patients with clip + iodine seed localisation (3.0%), dislodgement did not occur in other localisation methods (p = 0.999). The false-negativity of sentinel lymph node (SLN) was observed in 8 patients, the false-negativity of targeted lymph nodes (TLN) wasn ́t observed at all, the false-negativity rate (FNR) from the subcohort of ypN + patients for SLN is 9.6% and for TLN 0.0%. CONCLUSION: The IMTAD study indicated, that clip + iodine seed, magnetic seed and carbon suspension are statistically comparable in terms of complications during marker implantation and detection and marker dislodgement proving their safety, accuracy, and reliability in TAD. The study confirmed, that the FNR of the TLN was lower than the FNR of the SLN proving that the TLN is a better marker for axillary lymph node status after NAC. TRIAL REGISTRATION: NCT04580251. Name of registry: Clinicaltrials.gov. Date of registration: 8.10.2020.
PURPOSE: Localizing breast lesions by marking tumors and their detection using probes during surgery is a common part of clinical practice. Various nonwire localization systems were intended to be compared from different perspectives. METHODS: Various measurement experiments were performed. Localization techniques, including radioactive seed (RSLS), magnetically guided (MGLS), or radar (SLS), were compared in signal propagation in water and tissue environments, signal interference by surgical instruments, and the practical experience of surgeons. Individual experiments were thoroughly prospectively planned. RESULTS: The RSLS signal was detectable at the largest evaluated distance, ie, 60 mm. The SLS and MGLS signal detection was shorter, up to 25 mm to 45 mm and 30 mm, respectively. The signal intensity and the maximum detection distance in water differed slightly depending on the localization marker orientation to the probe, especially for SLS and MGLS. Signal propagation in the tissue was noted to a depth of 60 mm for RSLS, 50 mm for SLS, and 20 mm for MGLS. Except for the expected signal interferences by approaching surgical instruments from any direction for MGLS, the signal interruption for RSLS and SLS was observed only by inserting instruments directly between the localization marker and probe. Moreover, the SLS signal interference by instrument touch was noted. Based on surgeons' results, individual systems did not differ significantly for most measurement condition settings. CONCLUSION: Apparent differences noted among localization systems can help experts choose an appropriate system for a specific situation or reveal small nuances that have not yet been observed in clinical practice.
- MeSH
- lidé MeSH
- mikrochirurgie MeSH
- nádory prsu * diagnostické zobrazování chirurgie patologie MeSH
- prsy patologie MeSH
- segmentální mastektomie metody MeSH
- voda MeSH
- zaměřovací značky pro radioterapii MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
INTRODUCTION: Primary breast sarcoma is a very rare malignant type of breast tumours with an incidence of 0.1% of all primary breast malignancies. METHODS: We present a retrospective analysis of the case series from two hospitals in the Czech Republic with a review of the diagnostic and treatment approach to primary breast sarcomas with an analysis of published prognostic factors. RESULTS: Eleven patients were included in the study, 9 women and 2 men. Statistical evaluation revealed that tumour size (p = 0.1964), grade (p = 0.1667), margin distance (p = 0.5403), mitotic activity (p = 0.8577), or age (p = 0.7822) were not prognostic factors in our cohort. CONCLUSION: The analysis did not prove any of the factors, such as age, tumour size, grade, or mitotic activity, to be statistically significant prognostic factors. Based on the literature review, the most common published prognostic factors are tumour size, margin status, and grade, but the results are ambiguous.
- Publikační typ
- časopisecké články MeSH
Calcium channel blockers are among the most commonly used agents in the treatment of cardiovascular diseases. There are several known side-effects associated with their long-term use, whereas other potential adverse effects are yet to be proven. This study aims to evaluate the association between calcium channel blockers exposure and the incidence of second primary malignancy. We established a cohort of 1401 patients with colorectal cancer diagnosed in our institution between January 2003 and December 2016. Patients were followed-up until December 2020. The tumor characteristics and basic clinical data including medication information were obtained from the hospital information system database. Second malignancy was detected in 301 patients (21.5%), and occurred in 27.8% of patients who used calcium channel blockers compared to only 19.9% among non-users. Their use was associated with an increased incidence of bladder cancer in particular. Subanalysis of patients with second malignancy displayed a higher proportion of right-sided colon cancer compared to rectal carcinoma in non-users. Survival analysis revealed significantly better outcomes in early-stage colorectal cancer patients without a history of calcium channel blockers treatment or second primary malignancy.
- MeSH
- blokátory kalciových kanálů MeSH
- kardiovaskulární nemoci * MeSH
- kolon MeSH
- lidé MeSH
- nádory rekta * MeSH
- nežádoucí účinky léčiv * MeSH
- sekundární malignity * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Effects of low-frequency electromagnetic fields (LF EMF) on the activation of different tissue recovery processes have already been fully understood. Preliminary recent data demonstrated that a special case of sinusoidal electromagnetic fields, known as amplitude-modulated currents (AMC) could have a potential to accelerate the cell metabolism or cell migration. An AMC generator was designed to generate sinusoidal induced electric currents with the amplitude modulation and the harmonic carrier frequency of 5,000 Hz was modulated by frequencies of 1 to 100 Hz. The magnetic field peak was 6 mT, electric field intensity 2 V/m and the current density of induced electrical currents was approximately 1 A/m(2). The coil of the generator was adapted to easy handling and safe integration into the shelf of the CO(2) incubator. The shelf with the coil was prepared for the introduction of cells in standard plastic in vitro chambers. The tests focused on cells with migratory capacity after injury or during immunological processes and thus, mesenchymal stromal cells (MSC), dendritic cells (DC), and fibroblasts were chosen. The tests involved exposures of the cells to LF EMF (180 min/day) every day, for a period of three days, before examining them for cell death, morphology changes, and CD markers. The samples were tested by using MTT assay and the effects on the intracellular concentration of reactive oxygen species were quantified. The cell migration was finally measured with the help of the transwell migration assay. None of the cell types showed any decrease in the cell viability after the LF EMF application and the cells displayed minimum changes in reactive oxygen species. Functional changes (acceleration of cell migration) after AMC exposure were statistically significant for the MSC samples only. The acceleration of MSCs is associated with the production of MMP by these cells. The EMF has a potential to be a safe, clinically applicable selective activator of MSC homing, MSC paracrine production, and subsequent regeneration processes.
- MeSH
- buňky 3T3 MeSH
- dendritické buňky fyziologie MeSH
- elektromagnetická pole * MeSH
- fibroblasty fyziologie MeSH
- lidé MeSH
- matrixová metaloproteinasa 2 metabolismus MeSH
- mezenchymální kmenové buňky fyziologie MeSH
- myši MeSH
- parakrinní signalizace MeSH
- pohyb buněk * MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH