The impact of four pre-treatment techniques on the surface morphology and chemistry, residual stress, mechanical properties, corrosion resistance in a physiological saline solution and cell colonization of commercially pure titanium is examined in detail. Mechanical polishing, electrochemical etching, chemical etching in Kroll's reagent, and ion sputter etching with argon ions were applied. Surface morphologies reflect the nature of surface layer removal. Significant roughening of the surface and a characteristic microtopology become apparent as a result of the sensitivity of chemical and ion sputter etching to the grain orientation. The hardness in the near surface region was controlled by the amount of residual stress. Etching of the stressed surface layer led to a reduction in residual stress and surface hardness. A compact passivation layer composed of TiO, TiO2 and Ti2O3 native oxides imparted high corrosion resistance to the surface after mechanical polishing, chemical and electrochemical etching. The ion sputter etched surface showed substantially reduced corrosion resistance, where the corrosion process was controlled by electron transfer. The specific topology affected the adhesion of the cell to the surface rather than the cell area coverage. The cell area coverage increased with the corrosion stability of the surface.
- MeSH
- buněčné linie MeSH
- elektrochemické techniky MeSH
- koroze MeSH
- lidé MeSH
- oxidy chemie MeSH
- povrchové vlastnosti MeSH
- testování materiálů MeSH
- titan chemie MeSH
- tvrdost MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
The Zn-based alloys, alloyed with the elements of the 2nd group of the periodic table, are considered as potential biodegradable materials suitable for the fabrication of small orthopaedic implants or cardiovascular stents. Unfortunately, the as-cast Zn-based alloys do not fulfil the requirements for mechanical properties for such applications. Extrusion is a thermomechanical process which is very powerful for breaking the cast microstructure and enhancing mechanical characteristics of metallic materials. In this study, we focused on the influence of extrusion parameters, such as temperature and extrusion ratio, on microstructural and mechanical characteristics of a ZnMg0.8Ca0.2 (wt.%) alloy. The extrusion led to a significant grain refinement and the formation of a crystallographic texture. Extrusion temperature played a more significant role in the mean grain size compared to the extrusion ratio (ER). At lower extrusion temperatures, the texture was less intensive and the subsequent mechanical anisotropy was weaker. Constants for the prediction of the grain size based on the Zener-Hollomon parameter were obtained. Prediction of mechanical properties using the Hall-Petch relationship appeared to be difficult because of the dependence of the texture on the extrusion temperature. Extrusion at the temperatures of 200 °C (ER = 25:1) and 150 °C (ER = 11:1) led to mechanical performance fulfilling the requirements for implantology.
- MeSH
- biokompatibilní materiály * MeSH
- koroze MeSH
- slitiny * MeSH
- stenty MeSH
- teplota MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The goal of our study is to design BaTiO3 ferroelectric layers that will cover metal implants and provide improved osseointegration. We synthesized ferroelectric BaTiO3 layers on Pt/fused silica substrates, and we studied their physical and bio-properties. BaTiO3 and Pt layers were prepared using KrF excimer laser ablation at substrate temperature Ts in the range from 200°C to 750°C in vacuum or under oxygen pressure of 10 Pa, 15 Pa, and 20 Pa. The BaTiO3/Pt and Pt layers adhered well to the substrates. BaTiO3 films of crystallite size 60-140 nm were fabricated. Ferroelectric loops were measured and ferroelectricity was also confirmed using Raman scattering measurements. Results of atomic force microscopy topology and the X-ray diffraction structure of the BaTiO3/Pt/fused silica multilayers are presented. The adhesion, viability, growth, and osteogenic differentiation of human osteoblast-like Saos-2 cells were also studied. On days 1, 3, and 7 after seeding, the lowest cell numbers were found on non-ferroelectric BaTiO3, while the values on ferroelectric BaTiO3, on non-annealed and annealed Pt interlayers, and on the control tissue culture polystyrene dishes and microscopic glass slides were similar, and were usually significantly higher than on non-ferroelectric BaTiO3. A similar trend was observed for the intensity of the fluorescence of alkaline phosphatase, a medium-term marker of osteogenic differentiation, and of osteocalcin, a late marker of osteogenic differentiation. At the same time, the cell viability, tested on day 1 after seeding, was very high on all tested samples, reaching 93-99%. Ferroelectric BaTiO3 films deposited on metallic bone implants through a Pt interlayer can therefore markedly improve the osseointegration of these implants in comparison with non-ferroelectric BaTiO3 films.
- MeSH
- buněčné linie MeSH
- elektřina MeSH
- kostní náhrady chemie MeSH
- lasery MeSH
- lidé MeSH
- nanočástice chemie ultrastruktura MeSH
- osteoblasty cytologie MeSH
- osteogeneze MeSH
- oxid křemičitý chemie MeSH
- platina chemie MeSH
- protézy a implantáty MeSH
- sloučeniny barya chemie MeSH
- titan chemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BaTiO3 (BTO) layers were deposited by pulsed laser deposition (PLD) on TiNb, Pt/TiNb, Si (100), and fused silica substrates using various deposition conditions. Polycrystalline BTO with sizes of crystallites in the range from 90nm to 160nm was obtained at elevated substrate temperatures of (600°C-700°C). With increasing deposition temperature above 700°C the formation of unwanted rutile phase prevented the growth of perovskite ferroelectric BTO. Concurrently, with decreasing substrate temperature below 500°C, amorphous films were formed. Post-deposition annealing of the amorphous deposits allowed obtaining perovskite BTO. Using a very thin Pt interlayer between the BTO films and TiNb substrate enabled high-temperature growth of preferentially oriented BTO. Raman spectroscopy and electrical characterization indicated polar ferroelectric behaviour of the BTO films.
- MeSH
- biokompatibilní materiály chemie MeSH
- difrakce rentgenového záření MeSH
- elektřina MeSH
- elektrody MeSH
- lasery * MeSH
- mikroskopie elektronová rastrovací MeSH
- niob chemie MeSH
- oxid křemičitý chemie MeSH
- protézy a implantáty * MeSH
- Ramanova spektroskopie MeSH
- slitiny chemie MeSH
- sloučeniny barya chemie MeSH
- titan chemie MeSH
- Publikační typ
- časopisecké články MeSH