BACKGROUND: Pregnancy-associated plasma protein A (PAPP-A) is associated with adverse outcome of long-term hemodialysis patients (HD). The aim of the study was to test whether its homolog pregnancy-associated plasma protein A2 (PAPP-A2) can be detected in serum of HD patients and to define its significance. METHODS: The studied group consisted of 102 long-term HD patients and 25 healthy controls. HD patients were prospectively followed up for five years (2009-2014). PAPP-A2 was measured by surface plasmon resonance biosensor, PAPP-A by time resolved amplified cryptate emission. RESULTS: PAPP-A2, similarly as PAPP-A, was significantly increased in HD patients (median (interquartile range)) PAPP-A2: 6.2 (2.6-10.8) ng/mL, vs. 3.0 (0.7-5.9) ng/mL, p=0.006; PAPP-A: 18.9 (14.3-23.4) mIU/L, vs. 9.5 (8.4-10.5) mIU/L, p<0.001). In HD patients, PAPP-A2 correlated weakly but significantly with PAPP-A (τ=0.193, p=0.004). Unlike PAPP-A, PAPP-A2 was not significant for prognosis of HD patients when tested alone. There was a significant interaction between PAPP-A and PAPP-A2 on the mortality due to infection of HD patients (p=0.008). If PAPP-A was below median, mortality due to infection was significantly higher for patients with PAPP-A2 values above median than for patients with low PAPP-A2 levels (p=0.011). CONCLUSION: PAPP-A2 is increased in HD patients and interacts with PAPP-A on patients ́ prognosis.
- MeSH
- biologické markery krev MeSH
- chronické selhání ledvin krev diagnóza MeSH
- dialýza ledvin MeSH
- infekce mortalita MeSH
- lidé MeSH
- prognóza MeSH
- prospektivní studie MeSH
- studie případů a kontrol MeSH
- těhotenský plazmatický protein A analýza MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Recent outbreaks of foodborne illnesses have shown that foodborne bacterial pathogens present a significant threat to public health, resulting in an increased need for technologies capable of fast and reliable screening of food commodities. The optimal method of pathogen detection in foods should: (i) be rapid, specific, and sensitive; (ii) require minimum sample preparation; and (iii) be robust and cost-effective, thus enabling use in the field. Here we report the use of a SPR biosensor based on ultra-low fouling and functionalizable poly(carboxybetaine acrylamide) (pCBAA) brushes for the rapid and sensitive detection of bacterial pathogens in crude food samples utilizing a three-step detection assay. We studied both the surface resistance to fouling and the functional capabilities of these brushes with respect to each step of the assay, namely: (I) incubation of the sensor with crude food samples, resulting in the capture of bacteria by antibodies immobilized to the pCBAA coating, (II) binding of secondary biotinylated antibody (Ab2) to previously captured bacteria, and (III) binding of streptavidin-coated gold nanoparticles to the biotinylated Ab2 in order to enhance the sensor response. We also investigated the effects of the brush thickness on the biorecognition capabilities of the gold-grafted functionalized pCBAA coatings. We demonstrate that pCBAA-compared to standard low-fouling OEG-based alkanethiolate self-assemabled monolayers-exhibits superior surface resistance regarding both fouling from complex food samples as well as the non-specific binding of S-AuNPs. We further demonstrate that a SPR biosensor based on a pCBAA brush with a thickness as low as 20 nm was capable of detecting E. coli O157:H7 and Salmonella sp. in complex hamburger and cucumber samples with extraordinary sensitivity and specificity. The limits of detection for the two bacteria in cucumber and hamburger extracts were determined to be 57 CFU/mL and 17 CFU/mL for E. coli and 7.4 × 10(3) CFU/mL and 11.7 × 10(3)CFU/mL for Salmonella sp., respectively. In addition, we demonstrate the simultaneous detection of E. coli and Salmonella sp. in hamburger sample using a multichannel SPR biosensor having appropriate functional coatings.
- MeSH
- biosenzitivní techniky * MeSH
- Escherichia coli O157 izolace a purifikace patogenita MeSH
- imobilizační protilátky chemie MeSH
- kontaminace potravin MeSH
- lidé MeSH
- limita detekce MeSH
- nemoci přenášené potravou diagnóza mikrobiologie MeSH
- potravinářská mikrobiologie * MeSH
- povrchová plasmonová rezonance MeSH
- zlato chemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH