- MeSH
- lidé MeSH
- porodní asistentky * dějiny výchova MeSH
- studium ošetřovatelství * MeSH
- Check Tag
- lidé MeSH
Currently, for Sequential Injection Chromatography (SIC), only reversed phase C18 columns have been used for chromatographic separations. This article presents the first use of three different stationary phases: three core-shell particle-packed reversed phase columns in flow systems. The aim of this work was to extend the chromatographic capabilities of the SIC system. Despite the particle-packed columns reaching system pressures of ≤ 610 PSI, their conditions matched those of a commercially produced and optimised SIC system (SIChrom™ (FIAlab(®), USA)) with a 8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with a 4 mL reservoir and maximum system pressure of ≤ 1000 PSI. The selectivity of each of the tested columns, Ascentis(®) Express RP-Amide, Ascentis(®) Express Phenyl-Hexyl and Ascentis(®) Express C18 (30 mm × 4.6mm, core-shell particle size 2.7 μm), was compared by their ability to separate seven phenolic acids that are secondary metabolite substances widely distributed in plants. The separations of all of the components were performed by isocratic elution using binary mobile phases composed of acetonitrile and 0.065% phosphoric acid at pH 2.4 (a specific ratio was used for each column) at a flow-rate of 0.60 mL/min. The volume of the mobile phase was 3.8 mL for each separation. The injection volume of the sample was 10 μL for each separation. The UV detection wavelengths were set to 250, 280 and 325 nm. The RP-Amide column provided the highest chromatographic resolution and allowed for complete baseline separation of protocatechuic, syringic, vanillic, ferulic, sinapinic, p-coumaric and o-coumaric acids. The Phenyl-Hexyl and C18 columns were unable to completely separate the tested mixture, syringic and vanillic acid and ferulic and sinapinic acids could not be separated from one another. The analytical parameters were a LOD of 0.3 mg L(-1), a LOQ of 1.0 mg L(-1), a calibration range of 1.0-50.0 (100.0) mg L(-1) (r>0.997) and a system precision of 10 mg L(-1) with a RSD ≤ 1.65%. The high performance of the chromatography process with the RP-Amide column under optimised conditions was highlighted and well documented (HETP values ≤ 10 μm, peak symmetry ≤ 1.33, resolution ≥ 1.87 and time for one analysis <8.0 min). The results of these experiments confirmed the benefits of extending chromatographic selectivity using core-shell particle column technology in a SIC manifold.
Rapid and reliable detection, identification, and typing of bacterial species are necessary in response to natural or terrorist-caused outbreaks of infectious diseases and play crucial roles in diagnosis and efficient treatment. We report here two proteomic approaches with a high potential in the detection and identification of Coxiella burnetii, the causative agent of Q fever. The first of them starts with the acetonitrile (ACN) and trichloroacetic acid extractions of inactivated C. burnetii cells followed by the detection of extracted molecules and ions derived from the inactivated cells by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. In the second approach, identification of the proteins extracted by ACN is accomplished after enzymatic digestion by electrospray tandem mass spectrometry coupled to a nanoscale ultraperformance liquid chromatography (LC-MS/MS). In order to observe morphological differences on the surface structures upon extraction, the inactivated and treated cells of the bacterium were examined by electron microscopy. The LC-MS/MS approach has allowed identification of 20 proteins in the ACN extracts of C. burnetii strain RSA 493 that were observed in more than 3 out of 10 experiments.
- MeSH
- bakteriální proteiny MeSH
- chromatografie kapalinová MeSH
- Coxiella burnetii chemie izolace a purifikace MeSH
- databáze faktografické MeSH
- elektronová mikroskopie MeSH
- financování organizované MeSH
- spektrometrie hmotnostní - ionizace laserem za účasti matrice MeSH
- tandemová hmotnostní spektrometrie MeSH
- trypsin metabolismus MeSH
272 s. : il.
- NLK Obory
- lingvistika, lékařská terminologie