Information on the indoor environment as a source of exposure with potential adverse health effects is mostly limited to a few pollutant groups and indoor types. This study provides a comprehensive toxicological profile of chemical mixtures associated with dust from various types of indoor environments, namely cars, houses, prefabricated apartments, kindergartens, offices, public spaces, and schools. Organic extracts of two different polarities and bioaccessible extracts mimicking the gastrointestinal conditions were prepared from two different particle size fractions of dust. These extracts were tested on a battery of human cell-based bioassays to assess endocrine disrupting potentials. Furthermore, 155 chemicals from different pollutant groups were measured and their relevance for the bioactivity was determined using concentration addition modelling. The exhaustive and bioaccessible extracts of dust from the different microenvironments interfered with aryl hydrocarbon receptor, estrogen, androgen, glucocorticoid, and thyroid hormone (TH) receptor signalling, and with TH transport. Noteably, bioaccessible extracts from offices and public spaces showed higher estrogenic effects than the organic solvent extracts. 114 of the 155 targeted chemicals were detectable, but the observed bioactivity could be only marginally explained by the detected chemicals. Diverse toxicity patterns across different microenvironments that people inhabit throughout their lifetime indicate potential health and developmental risks, especially for children. Limited data on the endocrine disrupting potency of relevant chemical classes, especially those deployed as replacements for legacy contaminants, requires further study.
Many semi-volatile organic compounds (SVOCs) accumulate in indoor dust, which serves as a repository for those compounds. The presence of SVOCs in indoor environments is of concern because many of them are suspected to have toxic effects. Total SVOC concentrations in the dust are generally used for exposure assessment to indoor contaminants, assuming that 100% of the SVOCs is accessible for human uptake. However, such an assumption may potentially lead to an overestimated risk related to dust exposure. We applied a multi-ratio equilibrium passive sampling (MR-EPS) for estimation of SVOC accessibility in indoor settled dust using silicone passive samplers and three particle size dust fractions, <0.25 mm, 0.25-0.5 mm, and 1-2 mm in dry and wet conditions. Equilibrations were performed at various sampler-dust mass ratios to achieve different degrees of SVOC depletion, allowing the construction of a desorption isotherm. The desorption isotherms provided accessible fractions (FAS), equivalent air concentrations (CAIR), dust-air partition coefficients (KDUST-AIR) and organic carbon-air partition coefficients (KOC-AIR). The highest FAS were observed in the <0.25 mm dust fraction in wet conditions which is relevant for exposure assessment via oral ingestion. The highest CAIR were estimated for several organophosphorus flame retardants (OPFRs), polycyclic aromatic hydrocarbons (PAHs) and synthetic musks. The logKOC-AIR did not differ between dust particle sizes in dry and wet conditions but within compound groups, different relationships with hydrophobicity were observed. Equivalent lipid-based concentrations (CL⇌DUST) calculated using available lipid-silicone partition coefficients (KLIP-SIL) were compared with lipid-based concentrations (CL) measured in human-related samples collected from Europeans. For hexachlorobenzene (HCB), CL⇌DUST, and CL were similar, indicating equilibrium attainment between environment and human samples. Lipid-based concentrations for persistent legacy contaminants were also similar but lower for PBDEs in human samples. Overall, accessibility estimation using MR-EPS in dust further contributes to human risk assessment.
- MeSH
- hodnocení rizik MeSH
- lidé MeSH
- lipidy MeSH
- monitorování životního prostředí MeSH
- prach analýza MeSH
- retardanty hoření * analýza MeSH
- těkavé organické sloučeniny * analýza MeSH
- znečištění vzduchu ve vnitřním prostředí * analýza MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
As Europe's second longest river, the Danube is an important water source for drinking water and irrigation for many countries, before discharging into the Black Sea in the East. Per- and poly-fluoroalkyl substances (PFAS) have been observed over the last two decades in concentrations exceeding the European Union's drinking water guidelines for total sum of 20 select PFAS of 0.1 μg L-1. Their presence is a result of current and historical use and high environmental persistence, necessitating their monitoring for human risk assessments. The aim of this study is to use recently developed passive sampling technology to calculate time-integrated water concentrations and mass loads of 11 select PFAS at 9 sites along the Danube River. Results indicate ∑11 PFAS concentrations in the range of 9.3-29.6 ng L-1 were not in exceedance of EU drinking water guidelines, but perfluorooctanesulfonic acid (PFOS) was in exceedance of the environmental quality standard (0.65 ng L-1) at all sampling locations. The highest ∑11 PFAS mass loads were observed at Ruse (9.5 kg day-1) and Budapest (6.3 kg day-1), believed to be driven by proximity to industrial facilities and large populations (urban runoff). Finally, we estimate 4.9 kg of total PFAS (∑11 PFAS) were delivered to the Black Sea daily over Summer 2019.
POCIS is the most widely applied passive sampler of polar organic substances, because it was one of the first commercially available samplers for that purpose on the market, but also for its applicability for a wide range of substances and conditions. Its main weakness is the variability of sampling performance with exposure conditions. In our study we took a pragmatic approach and performed in situ calibration for a set of 76 pharmaceuticals and their metabolites in five sampling campaigns in surface water, covering various temperature and flow conditions. In individual campaigns, RS were calculated for up to 47 compounds ranging from 0.01 to 0.63 L d-1, with the overall median value of 0.10 L d-1. No clear changes of RS with water temperature or discharge could be found for any of the investigated substances. The absence of correlation of experimental RS with physical-chemical properties in combination with the lack of mechanistic understanding of compound uptake to POCIS implies that practical estimation of aqueous concentrations from uptake in POCIS depends on compound-specific experimental calibration data. Performance of POCIS was compared with grab sampling of water in seven field campaigns comprising multiple sampling sites, where sampling by both methods was done in parallel. The comparison showed that for 25 of 36 tested compounds more than 50% of POCIS-derived aqueous concentrations did not differ from median of grab sampling values more than by a factor of 2. Further, for 30 of 36 compounds, more than 80% of POCIS data did not differ from grab sampling data more than by a factor of 5. When accepting this level of accuracy, in situ derived sampling rates are sufficiently robust for application of POCIS for identification of spatial and temporal contamination trends in surface waters.
We comprehensively review the current state-of-the-art of environmental monitoring for hydrophobic organic contaminants in aqueous matrices using passive sampling devices. Principles of the theory of passive sampling are presented. Strategies for passive sampler design and operation, limitations in performance and data quality-assurance and quality-control are reviewed. Advances in applications of available passive sampling devices are extensively critiqued. Future trends and current challenges facing practitioners and barriers to further adoption of the devices are discussed.
Non-target analysis (NTA) employing high-resolution mass spectrometry is a commonly applied approach for the detection of novel chemicals of emerging concern in complex environmental samples. NTA typically results in large and information-rich datasets that require computer aided (ideally automated) strategies for their processing and interpretation. Such strategies do however raise the challenge of reproducibility between and within different processing workflows. An effective strategy to mitigate such problems is the implementation of inter-laboratory studies (ILS) with the aim to evaluate different workflows and agree on harmonized/standardized quality control procedures. Here we present the data generated during such an ILS. This study was organized through the Norman Network and included 21 participants from 11 countries. A set of samples based on the passive sampling of drinking water pre and post treatment was shipped to all the participating laboratories for analysis, using one pre-defined method and one locally (i.e. in-house) developed method. The data generated represents a valuable resource (i.e. benchmark) for future developments of algorithms and workflows for NTA experiments.
Total concentrations of hydrophobic organic contaminants (HOCs) in sediment present a poor quality assessment parameter for aquatic organism exposure and environmental risk because they do not reflect contaminant bioavailability. The bioavailability issue of HOCs in sediments can be addressed by application of multi-ratio equilibrium passive sampling (EPS). In this study, riverbed sediment samples were collected during the Joint Danube Survey at 9 locations along the Danube River in 2013. Samples were ex-situ equilibrated with silicone passive samplers. Desorption isotherms were constructed, yielding two endpoints: pore water (CW:0) and accessible (CAS:0) concentration of polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), polycyclic aromatic hydrocarbons (PAHs) and polybrominated diphenyl ethers in sediment. CW:0 concentrations of DDT and its breakdown products exhibited elevated levels in the low Danube, with the maximum in the river delta. Other investigated HOCs did not show any clear spatial trends along the river, and only a moderate CW:0 variability. CAS:0 in sediment ranged from 10 to 90% of the total concentration in sediment. CW:0 was compared with freely dissolved concentration in the overlaying surface water, measured likewise by passive sampling. The comparison indicated potential compound release from sediment to the water phase for PAHs with less than four aromatic rings, and for remaining HOCs either equilibrium between sediment and water, or potential compound deposition in sediment. Sorption partition coefficients of HOC to organic carbon correlated well with octanol-water partition coefficients (KOW), showing stronger sorption of PAHs to sediment than that of PCBs and OCPs having equal logKOW. Comparison of CW:0 values with European environmental quality standards indicated potential exceedance for hexachlorobenzene, fluoranthene and benzo[a]pyrene at several sites. The study demonstrates the utility of passive sampling as an innovative approach for risk-oriented monitoring of HOCs in river catchments.
The concentrations of hydrophobic organic compounds (HOCs) in aquatic biota are used for compliance, as well as time and spatial trend monitoring in the aqueous environment (European Union water framework directive, OSPAR). Because of trophic magnification in the food chain, the thermodynamic levels of HOCs, for example, polychlorinated biphenyl congeners, dichlorodiphenyltrichloroethane, and brominated diphenyl ether congeners, in higher trophic level (TL) organisms are expected to be strongly elevated above those in water. This work compares lipid-based concentrations at equilibrium with the water phase derived from aqueous passive sampling (CL⇌water) with the lipid-based concentrations in fillet and liver of fish (CL) at different TLs for three water bodies in the Czech Republic and Slovakia. The CL values of HOCs in fish were near CL⇌water, only after trophic magnification up to TL = 4. For fish at lower TL, CL progressively decreased relative to CL⇌water as KOW of HOCs increased above 106. The CL value decreasing toward the bottom of the food chain suggests nonequilibrium for primary producers (algae), which is in agreement with modeling passive HOC uptake by algae. Because trophic magnification and the resulting CL in fish exhibit large natural variability, CL⇌water is a viable alternative for monitoring HOCs using fish, showing a twofold lower confidence range and requiring less samples.
- MeSH
- chemické látky znečišťující vodu * analýza MeSH
- monitorování životního prostředí * MeSH
- potravní řetězec MeSH
- ryby MeSH
- sladká voda MeSH
- voda MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika MeSH
- Slovenská republika MeSH
The occurrence of chemical and biological contaminants of emerging concern (CECs) was investigated in treated wastewater intended for reuse in agriculture. An agarose hydrogel diffusion-based passive sampler was exposed to the outlet of a wastewater treatment plant (WWTP) located in Cyprus, which is equipped with membrane bioreactor (MBR). Passive samplers in triplicate were exposed according to a time-series exposure plan with maximum exposure duration of 28 days. Composite flow-proportional wastewater samples were collected in parallel with the passive sampling exposure plan and were processed by solid phase extraction using HORIZON SPE-DEX 4790 and the same sorbent material (Oasis HLB) as in the passive sampler. The analysis of passive samplers and wastewater samples enabled (i) the field-scale calibration of the passive sampler prototype by the calculation of in situ sampling rates of target substances, and (ii) the investigation of in silico predicted transformation products of the four most ecotoxicologically hazardous antibiotics (azithromycin, clarithromycin, erythromycin, ofloxacin). Additionally, the wastewater samples were subjected to the analysis of seven preselected antibiotic resistant genes (ARGs) and one mobile resistant element (int1). All extracts were analyzed for chemicals in a single batch using a highly sensitive method for pharmaceuticals, antibiotics and illicit drugs by liquid chromatography tandem MS/MS (LC-QQQ) and for various other target compounds (2316 compounds in total) by liquid chromatography high-resolution mass spectrometry (LC-HRMS). 279 CECs and all investigated ARGs (except for blaCTX-M-32) were detected, highlighting potential chemical and biological hazards related to wastewater reuse practices. 16 CECs were prioritized following ecotoxicological risk assessment, whereas sul1 and the mobile resistant element (int1) showed the highest abundance. Comprehensive monitoring efforts using novel sampling methods such as passive sampling, wide-scope target screening and molecular analysis are required to assure safe application of wastewater reuse and avoid spread and crop uptake of potentially hazardous chemicals.