- MeSH
- dítě MeSH
- hluchota terapie MeSH
- kochleární implantace * metody přístrojové vybavení rehabilitace trendy využití MeSH
- kochleární implantáty MeSH
- lidé MeSH
- perioperační péče MeSH
- poruchy sluchu diagnóza epidemiologie etiologie klasifikace psychologie terapie vrozené MeSH
- řeč MeSH
- rehabilitace MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
OBJECTIVES: Autism is a severe neurodevelopmental disorder with a high rate of epilepsy and subclinical epileptiform activity. High physical connectivity on a microcolumnar level leading to epileptiform activity and low functional informational connectivity are assumed in autism. The aim of this study was to investigate nonlinear EEG brain dynamics in terms of synchronization in a group of children with autism spectrum disorders compared to a control group. We expected a lower degree of synchronization in autistic subjects. METHODS: The autistic group consisted of 27 patients with autism spectrum disorders diagnosed according to ICD-10. The mean age of the sample was 7.1 (SD 3.6) years, 14 of them were mentally retarded. Normal EEG was found in 9 patients, epileptiform EEG in 18 autistic patients. Four patients had a history of epileptic seizures, fully compensated in long term. The control group consisted of 20 children (mean age of 8.4, SD 2.3 years) with normal intelligence, without an epileptic history, investigated within the frame of the research program for cochlear implantation. They had normal neurological examination and suffered from perceptive deafness. Normal EEG was found in 17 of the control subjects, epileptiform EEG was in 3 control subjects. We analyzed night sleep EEG recordings from 10 channels (F3, F4, F7, F8, C3, C4, T3, T4, P3 and P4) with the inclusion of sleep stages NREM 2, 3 and 4 in the subsequent analyses. Coarse-grained entropy information rates between neighbouring electrodes were computed, expressing the synchronization between 11 selected electrode couples. RESULTS: Synchronization was significantly lower in the autistic group in all three examined NREM stages even when age and intelligence were taken into account as covariates. CONCLUSIONS: The results of the study confirmed the validity of the underconnectivity model in autism.
Závěrečná zpráva o řešení grantu Interní grantové agentury MZ ČR
168 l. : il., tab., grafy ; 30 cm
1) Projekt ověřuje spolehlivost nové objektivní audiometrické metody, Steady State Evoked Potentials (SSEP). U souboru 60 sluchově postižených dětí srovnává výsledky této metody s výsledky klasické tónové audiometrie. Metoda je určena pro děti již od kojenckého věku a rozšíří úzkou škálu diagnostických možností vyšetřování sluchu nejen u kandidátů kochleární implantace. 2) Zabývá se hodnocením významnosti 18 faktorů, které ovlivňují přínos kochleární implantace. Hodnotí je na základě výsledků v testechpercepce řeči u 100 dětí, uživatel kochleárního implantátu. Cílem práce je najít diagnostický nástroj, který by umožnil předpovědět přínos implantace s přesností dostatečnou pro klinickou praxi.; 1) The project is to verify the reliability of a new objective audiometric method, Steady State Evoked Potentials (SSEP). In 60 children with hearing impairments, it compares the results of this method with the results of the classic tone audiometry. Themethod is intended for children of suckling age and above and will extend the narrow scale of diagnostic tools for hearing assessment not only for candidates of cochlear implantation. 2) The project evaluates the significance of 18 factors, which affectthe benefits from cochlear implantation. They are evaluated on the basis of the results of speech perception tests in 100 children who are users of cochlear implants. The objective of this work is to find diagnostic tools that would predict the implantbenefits with accury that is appropriate for clinical practice.
- MeSH
- audiometrie evokovanou odpovědí metody MeSH
- kochleární implantace metody MeSH
- kochleární implantáty MeSH
- kojenec MeSH
- poruchy sluchu diagnóza MeSH
- předškolní dítě MeSH
- sluchové evokované potenciály MeSH
- sluchové testy MeSH
- Check Tag
- kojenec MeSH
- předškolní dítě MeSH
- Konspekt
- Pediatrie
- NLK Obory
- otorinolaryngologie
- pediatrie
- NLK Publikační typ
- závěrečné zprávy o řešení grantu IGA MZ ČR
Autoři práce vyhodnotili stav sluchu a řeči u 124 dětí, uživatelů kochleárního implantátu, kteří byli v době vyšetření minimálně tři roky po operaci. Získané výsledky porovnali s výsledky týmového předoperačního hodnocení kvantifikovaného pomocí škály ChIP (česká verze). Škála posuzuje předpoklady pro využití kochleárního implantátu. Statistickým zpracováním dat se autoři pokusili určit prediktivní hodnotu této vyšetřovací metody.
The authors of the paper evaluated hearing and speech in 124 children, cochlear implant users, who at the time of examination were at least 3 years after the surgery. The acquired results were compared to the outcomes of preoperative examination quantified by means of the ChIP scale (Czech version). The scale assesses the prerequisites for the use of a cochlear implant. Using the statistic data processing the authors have tried to determine the predictive value of this method.
Studie srovnává výsledky dvou vyšetření sluchu metodou ustálených evokovaných potenciálů (SSEP – Steady State Evoked Potentials) u malých dětí, které byly provedeny s časovým odstupem několika měsíců. Metodu SSEP používáme na naší klinice od července 1999. Její hlavní výhodou je frekvenční specifikace. Pacienty vyšetřujeme na frekvencích 0,5, 1, 2 a 4 kHz. Do studie bylo zařazeno 64 dětí, z nichž u 45 dětí byla v pozdějším období provedena kochleární implantace. Výsledky studie ukazují na vysokou korelaci hodnot prahu sluchu dvou vyšetření metodou SSEP a potvrzují její spolehlivost.
The study presents the comparisons of results of two examinations of hearing carried out in young children by means of the Steady State Evoked Potentials (SSEP) method with the interval of several months. The SSEP method has been applied at our clinic since July 1999. Its main advantage is the frequency specificity. Patients are examined at the frequencies of 0.5, 1, 2 and 4 kHz. The study comprised 64 children, of whom 45 were later implanted. The results of the study indicate a high correlation of threshold values in the two examinatinos carried out by means of SSEP method and thus confirm its reliability.