Extracorporeal membrane oxygenation (ECMO) is an established tool for respiratory and circulatory support. In computed tomography, altered hemodynamics in ECMO patients requires special considerations and handling in contrast injection and its timing. In this article, we demonstrate changes in hemodynamics in ECMO patients captured on contrast-enhanced CT examinations and pitfalls in strategies for contrast injection in relation to the ECMO flow, cardiac function and the placement of ECMO cannulas. Contrast-enhanced CT of patients with ECMO requires prior knowledge of the ECMO cannulas, central venous lines, changes of hemodynamics induced by low cardiac output and the influence of adjustment of ECMO on blood flow in order to optimize injection of the contrast material and timing of the scan. Special considerations include temporary reduction of the ECMO flow, selection of the injection site and increasing volume or flow rate of the contrast material.
- MeSH
- dospělí MeSH
- hemodynamika * MeSH
- kontrastní látky aplikace a dávkování analýza MeSH
- lidé středního věku MeSH
- lidé MeSH
- mimotělní membránová oxygenace metody MeSH
- počítačová rentgenová tomografie metody MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Determination of Iopromide and Iopamidole in surface and waste waters was developed. A porous graphitic carbon sorbent was used for pre-concentration and separation of analytes, in combination with tandem mass spectrometry as detection technique. The method was validated and applied in routine analyses. Its characteristics such as repeatability, limits of detection and determination are presented together with evaluation of matrix effects. The working range was 20–1000 ng L–1, limit of determination 20 ng L–1 and expanded uncertainty 30 %.
- MeSH
- chemické látky znečišťující vodu * analýza MeSH
- chemické techniky analytické * MeSH
- hmotnostní spektrometrie MeSH
- johexol analogy a deriváty analýza MeSH
- kontrastní látky * analýza MeSH
- kyselina jothalamová analogy a deriváty analýza chemie MeSH
- kyseliny trijodbenzoové analýza chemie MeSH
- referenční standardy MeSH
- testování odbornosti laboratoří MeSH
- vysokoúčinná kapalinová chromatografie MeSH
Dynamic contrast-enhanced ultrasound (DCE-US) imaging is a promising diagnostic method, which enables the evaluation of tissue perfusion via different parameters. The mean transit time and time-to-peak parameters are the main time parameters and their values depend on the model used for the approximation of the noisy perfusion curves. In this paper, we described a new comparison of different perfusion models using a tissue mimicking phantom. The following models were compared: log-normal, lagged, Erlang, Gamma and the local density random walk model. We discovered that the mean-square error is not the best criterion for model evaluation. More important is the comparison between the estimated time perfusion parameters and the physical parameters of the developed tissue mimicking phantom. Based on the statistical analysis, we can suggest that for the DCE-US perfusion analysis more models should be used, excluding the log-normal model, which gives the highest error of mean transit time value.
- MeSH
- algoritmy * MeSH
- biologické modely * MeSH
- fantomy radiodiagnostické MeSH
- indikátorové diluční techniky * MeSH
- interpretace obrazu počítačem metody MeSH
- kontrastní látky analýza farmakokinetika MeSH
- lidé MeSH
- počítačová simulace MeSH
- reprodukovatelnost výsledků MeSH
- senzitivita a specificita MeSH
- ultrasonografie metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
Pokusné práce s touto látkou (Urokonem) jakožto kontrastní látkou v rentgenografii vyžadují biochemické sledování této látky. Třeba zjistit vstřebávání a vylučování a kontrolovat její množstvív tělních tekutinách. K tomu účelu vypracováno stanovení Urokonu, založené na principu stanovení aromatických aminosloučenin. Na základě systematického studia podmínek hydrolýzy, diazotace a kopulace vypracován reprodukovatelný postup vhodný pro stanovení 2,4,6-trijod-3-acetylaminobenzoanu sodného v biologickém materiálu