Can the gold standard be beaten? How reliable are various modifications of the Synacthen test compared to the insulin tolerance test
Language English Country Czech Republic Media print
Document type Comparative Study, Journal Article, Observational Study
PubMed
28948823
DOI
10.33549/physiolres.933729
PII: 933729
Knihovny.cz E-resources
- MeSH
- Adult MeSH
- Hydrocortisone analysis blood MeSH
- Insulin administration & dosage standards MeSH
- Insulin Resistance physiology MeSH
- Cosyntropin administration & dosage standards MeSH
- Humans MeSH
- Reference Standards MeSH
- Reproducibility of Results MeSH
- Saliva chemistry metabolism MeSH
- Pituitary-Adrenal System drug effects metabolism MeSH
- Hypothalamo-Hypophyseal System drug effects metabolism MeSH
- Check Tag
- Adult MeSH
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Observational Study MeSH
- Comparative Study MeSH
- Names of Substances
- adrenocorticotropin zinc MeSH Browser
- Hydrocortisone MeSH
- Insulin MeSH
- Cosyntropin MeSH
Criteria for the evaluation of the insulin tolerance test (ITT) and Synacthen test are still a matter of debate. The objective of the study was to make a comparison of serum and salivary cortisol during four stimulation tests. Sixty four healthy volunteers underwent the ITT, the Synacthen test with 1 (LDST), 10 (MDST) and 250 (HDST) microg dose of ACTH. Maximum serum cortisol response was observed at the 90 min of the ITT (49 %), HDST (89 %) and MDST (56 %) and at the 40 min of the LDST (44 %). Results expressed as 95 % confidence intervals: 408.0-843.6 and 289.5-868.1 nmol/l in the IIT at 60 and 90 min. In the HDST and the MDST serum cortisol reached the maximum at 90 min 542.6-1245.5 and 444.2-871.3 nmol/l. Levels of salivary cortisol followed the same pattern as serum cortisol. Salivary cortisol reached the maximum response in the HDST and the MDST at 90 min and at 40 min in the LDST. We confirmed good reliability of all tests with respect to timing of response and maximum response compared to the ITT. We proved that the MDST test can provide the similar response in serum cortisol to the HDST. Measuring either salivary cortisol or ACTH levels did not provide any additional benefit then measuring serum cortisol by itself.
References provided by Crossref.org
Are there sex differences in the reaction of undercarboxylated osteocalcin to hypoglycemia?
Steroid diagnostics of 21st century in the light of their new roles and analytical tools
Losing stinks! The effect of competition outcome on body odour quality