PURPOSE: Infarct lesion volume (ILV) may serve as an imaging biomarker for clinical outcomes in the early post-treatment stage in patients with acute ischemic stroke. The aim of this study was to evaluate the inter- and intra-rater reliability of manual segmentation of ILV on follow-up non-contrast CT (NCCT) scans. METHODS: Fifty patients from the Prove-IT study were randomly selected for this analysis. Three raters manually segmented ILV on 24-h NCCT scans, slice by slice, three times. The reference standard for ILV was generated by the Simultaneous Truth And Performance Level estimation (STAPLE) algorithm. Intra- and inter-rater reliability was evaluated, using metrics of intraclass correlation coefficient (ICC) regarding lesion volume and the Dice similarity coefficient (DSC). RESULTS: Median age of the 50 subjects included was 74.5 years (interquartile range [IQR] 67-80), 54% were women, median baseline National Institutes of Health Stroke Scale was 18 (IQR 11-22), median baseline ASPECTS was 9 (IQR 6-10). The mean reference standard ILV was 92.5 ml (standard deviation (SD) ± 100.9 ml). The manually segmented ILV ranged from 88.2 ± 91.5 to 135.5 ± 119.9 ml (means referring to the variation between readers, SD within readers). Inter-rater ICC was 0.83 (95%CI: 0.76-0.88); intra-rater ICC ranged from 0.85 (95%CI: 0.72-0.92) to 0.95 (95%CI: 0.91-0.97). The mean DSC among the three readers ranged from 65.5 ± 22.9 to 76.4 ± 17.1% and the mean overall DSC was 72.8 ± 23.0%. CONCLUSION: Manual ILV measurements on follow-up CT scans are reliable to measure the radiological outcome despite some variability.
- MeSH
- algoritmy MeSH
- cévní mozková příhoda * diagnostické zobrazování MeSH
- ischemická cévní mozková příhoda * MeSH
- lidé MeSH
- počítačová rentgenová tomografie metody MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Successful reperfusion determines the treatment effect of endovascular thrombectomy. We evaluated stent-retriever characteristics and their relation to reperfusion in the ESCAPE-NA1 trial. METHODS: Independent re-scoring of reperfusion grade for each attempt was conducted. The following characteristics were evaluated: stent-retriever length and diameter, thrombus position within stent-retriever, bypass effect, deployment in the superior or inferior MCA trunk, use of balloon guide catheter and distal access catheter. Primary outcome was successful reperfusion defined as expanded thrombolysis in cerebral infarction (eTICI) 2b-3 per attempt. The secondary outcome was successful reperfusion eTICI 2b-3 after the first attempt. Separate regression models for each stent-retriever characteristic and an exploratory multivariable modeling to test the impact of all characteristics on successful reperfusion were built. RESULTS: Of 1105 patients in the trial, 809 with the stent-retriever use (1241 attempts) were included in the primary analysis. The stent-retriever was used as the first-line approach in 751 attempts. A successful attempt was associated with thrombus position within the proximal or middle third of the stent (OR 2.06; 95% CI: 1.24-3.40 and OR 1.92; 95% CI: 1.16-3.15 compared to the distal third respectively) and with bypass effect (OR 1.7; 95% CI: 1.07-2.72). Thrombus position within the proximal or middle third (OR 2.80; 95% CI: 1.47-5.35 and OR 2.05; 95% CI: 1.09-3.84, respectively) was associated with first-pass eTICI 2b-3 reperfusion. In the exploratory analysis accounting for all characteristics, bypass effect was the only independent predictor of eTICI 2b-3 reperfusion (OR 1.95; 95% CI: 1.10-3.46). CONCLUSION: The presence of bypass effect and thrombus positioning within the proximal and middle third of the stent-retriever were strongly associated with successful reperfusion.
BACKGROUND AND PURPOSE: Manual segmentation of infarct volume on follow-up MRI diffusion-weighted imaging (MRI-DWI) is considered the gold standard but is prone to rater variability. We assess the variability of manual segmentations of MRI-DWI infarct volume. METHODS: Consecutive patients (May 2018 to May 2019) with the anterior circulation stroke and endovascularly treated were enrolled. All patients underwent 24- to 32-hour follow-up MRI. Three users manually segmented DWI infarct volumes slice by slice twice. The reference standard of DWI infarct volume was generated by the STAPLE algorithm. Intra- and interrater reliability was evaluated using the intraclass correlation coefficient (ICC) by comparing manual segmentations with the reference standard. Spatial measurements were evaluated using metrics of the Dice similarity coefficient (DSC). Volumetric measurements were compared using the lesion volume. RESULTS: The dataset consisted of 44 patients, mean (SD) age was 70.1 years (±10.3), 43% were women, and median baseline NIHSS score was 16. Among three users, the mean DSC for MRI-DWI infarct volume segmentations ranged from 80.6% ± 11.7% to 88.6% ± 7.5%, and the mean absolute volume difference was 2.8 ± 6.8 to 13.0 ± 14.0 ml. Interrater ICC among the users for DSC and infarct volume was .86 (95% confidence interval [95% CI]: .78-.91) and .997 (95% CI: .995-.998). Intrarater ICC for the three users was .83 (95% CI: .69-.93), .84 (95% CI: .72-.91), and .80 (95% CI: .64-.89) for DSC, and .99 (95% CI: .987-.996), .991 (95% CI: .983-.995), and .996 (95% CI: .993-.998) for infarct volume. CONCLUSIONS: Manual segmentation of infarct volume on follow-up MRI-DWI shows excellent agreement and good spatial overlap with the reference standard, suggesting its usefulness for measuring infarct volume on 24- to 32-hour MRI-DWI.
- MeSH
- algoritmy MeSH
- difuzní magnetická rezonance metody MeSH
- endovaskulární výkony metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- mozkový infarkt diagnostické zobrazování patologie terapie MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH