BACKGROUND: We aimed to assess the diagnostic utility of the Dimension EXL LOCI High-Sensitivity Troponin I (hs-cTnI-EXL) assay. METHODS: This multicenter study included patients with chest discomfort presenting to the emergency department. Diagnoses were centrally and independently adjudicated by two cardiologists using all available clinical information. Adjudication was performed twice including serial measurements of high-sensitivity cardiac troponin (hs-cTn) I-Architect (primary analysis) and serial measurements of hs-cTnT-Elecsys (secondary analysis) in addition to the clinically used (hs)-cTn. The primary objective was to assess and compare the discriminatory performance of hs-cTnI-EXL, hs-cTnI-Architect and hs-cTnT-Elecsys for acute myocardial infarction (MI). Furthermore, we derived and validated a hs-cTnI-EXL-specific 0/1h-algorithm. RESULTS: Adjudicated MI was the diagnosis in 204/1454 (14%) patients. The area under the receiver operating characteristics curve for hs-cTnI-EXL was 0.94 (95%CI, 0.93-0.96), and comparable to hs-cTnI-Architect (0.95; 95%CI, 0.93-0.96) and hs-cTnT-Elecsys (0.93; 95%CI, 0.91-0.95). In the derivation cohort (n = 813), optimal criteria for rule-out of MI were <9ng/L at presentation (if chest pain onset >3h) or <9ng/L and 0h-1h-change <5ng/L, and for rule-in ≥160ng/L at presentation or 0h-1h-change ≥100ng/L. In the validation cohort (n = 345), these cut-offs ruled-out 56% of patients (negative predictive value 99.5% (95%CI, 97.1-99.9), sensitivity 97.8% (95%CI, 88.7-99.6)), and ruled-in 9% (positive predictive value 83.3% (95%CI, 66.4-92.7), specificity 98.3% (95%CI, 96.1-99.3)). Secondary analyses using adjudication based on hs-cTnT measurements confirmed the findings. CONCLUSIONS: The overall performance of the hs-cTnI-EXL was comparable to best-validated hs-cTnT/I assays and an assay-specific 0/1h-algorithm safely rules out and accurately rules in acute MI. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov number, NCT00470587.
- MeSH
- biologické markery MeSH
- infarkt myokardu * diagnóza MeSH
- lidé MeSH
- prospektivní studie MeSH
- ROC křivka MeSH
- troponin I * MeSH
- troponin T MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
INTRODUCTION AND OBJECTIVES: Release kinetics of high-sensitivity cardiac troponin (hs-cTn) T and I in patients with acute myocardial infarction (AMI) are incompletely understood. We aimed to assess whether hs-cTnT/I release in early AMI is near linear. METHODS: In a prospective diagnostic multicenter study the acute release of hs-cTnT and hs-cTnI within 1 and 2hours from presentation to the emergency department was quantified using 3 hs-cTnT/I assays in patients with suspected AMI. The primary endpoint was correlation between hs-cTn changes from presentation to 1 hour vs changes from presentation to 2hours, among all AMI patients and different prespecified subgroups. The final diagnosis was adjudicated by 2 independent cardiologists, based on serial hs-cTnT from the serial study blood samples and additional locally measured hs-cTn values. RESULTS: Among 2437 patients with complete hs-cTnT data, AMI was the adjudicated diagnosis in 376 patients (15%). For hs-cTnT, the correlation coefficient between 0- to 1-hour change and 0- to 2 hour change was 0.931 (95%CI, 0.916-0.944), P <.001. Similar findings were obtained with hs-cTnI (Architect) with correlation coefficients between 0- to 1-hour change and 0- to 2 hour change of 0.969 and hs-cTnI (Centaur) of 0.934 (P <.001 for both). Findings were consistent among type 1 and type 2 AMI and in the subgroup of patients presenting very early after chest pain onset. CONCLUSIONS: Patients presenting with early AMI showed a near linear release of hs-cTnT and hs-cTnI. This near linearity provides the pathophysiological basis for rapid diagnostic algorithms using 0- to 1-hour changes as surrogates for 0- to 2 hour or 0- to 3 hour changes. Registered at ClinicalTrials.gov (Identifier: NCT00470587).
- MeSH
- biologické markery MeSH
- infarkt myokardu * diagnóza MeSH
- kinetika MeSH
- lidé MeSH
- prospektivní studie MeSH
- troponin I MeSH
- troponin T * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
BACKGROUND: Determination of blood donor hemoglobin (Hb) levels is a pre-requisite to ensure donor safety and blood product quality. We aimed to identify Hb measurement practices across blood donation services and to what extent differences associate with low-Hb deferral rates. METHODS: An online survey was performed among Biomedical Excellence for Safer Transfusion (BEST) Collaborative members, extended with published data. Multivariable negative-binomial regression models were built to estimate adjusted associations of minimum donation intervals, Hb cut-offs (high, ≥13.5 g/dL in men or ≥ 12.5 g/dL in women, vs. lower values), iron monitoring (yes/no), providing or prescribing iron supplementation (yes/no), post-versus pre-donation Hb measurement and geographical location (Asian vs. rest), with low-Hb deferral rates. RESULTS: Data were included from 38 blood services. Low-Hb deferral rates varied from 0.11% to 8.81% among men and 0.84% to 31.85% among women. Services with longer minimum donation intervals had significantly lower deferral rates among both women (rate ratio, RR 0.53, 95%CI 0.33-0.84) and men (RR 0.53, 95%CI 0.31-0.90). In women, iron supplementation was associated with lower Hb deferral rates (RR 0.47, 95%CI 0.23-0.94). Finally, being located in Asia was associated with higher low-Hb deferral rates; RR 9.10 (95%CI 3.89-21.27) for women and 6.76 (95%CI 2.45-18.68) for men. CONCLUSION: Differences in Hb measurement and eligibility criteria, particularly longer donation intervals and iron supplementation in women, are associated with variations in low-Hb deferral rates. These insights could help improve both blood donation service efficiency and donor care.
- MeSH
- časové faktory MeSH
- dárci krve statistika a číselné údaje MeSH
- hematologické testy MeSH
- hemoglobiny metabolismus MeSH
- krevní transfuze metody MeSH
- lidé MeSH
- průzkumy a dotazníky MeSH
- výběr dárců MeSH
- železo metabolismus MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Aims: We aimed to evaluate the impact of age on the performance of the European Society of Cardiology (ESC) 0/1h-algorithms and to derive and externally validate alternative cut-offs specific to older patients. Methods and results: We prospectively enrolled patients presenting to the emergency department (ED) with symptoms suggestive of acute myocardial infarction in three large diagnostic studies. Final diagnoses were adjudicated by two independent cardiologists. High-sensitivity cardiac troponin (hs-cTn) T and I concentrations were measured at presentation and after 1 h. Patients were stratified according to age [<55 years (young), ≥55 to <70 years (middle-age), ≥70 years (old)]. Rule-out safety of the ESC hs-cTnT 0/1h-algorithm was very high in all age-strata: sensitivity 100% [95% confidence interval (95% CI) 94.9-100] in young, 99.3% (95% CI 96.0-99.9) in middle-age, and 99.3% (95% CI 97.5-99.8) in old patients. Accuracy of rule-in decreased with age: specificity 97.0% (95% CI 95.8-97.9) in young, 96.1% (95% CI 94.5-97.2) in middle-age, and 92.7% (95% CI 90.7-94.3) in older patients. Triage efficacy decreased with increasing age (young 93%, middle-age 80%, old 55%, P < 0.001). Similar results were found for the ESC hs-cTnT 0/1h-algorithm. Alternative, slightly higher cut-off concentrations optimized for older patients maintained very high safety of rule-out, increased specificity of rule-in (P < 0.01), reduced overall efficacy for hs-cTnT (P < 0.01), while maintaining efficacy for hs-cTnI. Findings were confirmed in two validation cohorts (n = 2767). Conclusion: While safety of the ESC 0/1h-algorithms remained very high, increasing age significantly reduced overall efficacy and the accuracy of rule-in. Alternative slightly higher cut-off concentrations may be considered for older patients, particularly if using hs-cTnI. Clinical Trial Registration: https://clinicaltrials.gov/ct2/show/NCT00470587, number NCT00470587 and NCT02355457 (BACC).
- MeSH
- algoritmy MeSH
- časná diagnóza MeSH
- dospělí MeSH
- infarkt myokardu diagnóza epidemiologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- senioři MeSH
- senzitivita a specificita MeSH
- směrnice pro lékařskou praxi jako téma MeSH
- troponin krev MeSH
- věkové faktory MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BACKGROUND: Four strategies for very early rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I (hs-cTnI) have been identified. It remains unclear which strategy is most attractive for clinical application. METHODS: We prospectively enrolled unselected patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction. The final diagnosis was adjudicated by 2 independent cardiologists. Hs-cTnI levels were measured at presentation and after 1 hour in a blinded fashion. We directly compared all 4 hs-cTnI-based rule-out strategies: limit of detection (LOD, hs-cTnI<2 ng/L), single cutoff (hs-cTnI<5 ng/L), 1-hour algorithm (hs-cTnI<5 ng/L and 1-hour change<2 ng/L), and the 0/1-hour algorithm recommended in the European Society of Cardiology guideline combining LOD and 1-hour algorithm. RESULTS: Among 2828 enrolled patients, acute myocardial infarction was the final diagnosis in 451 (16%) patients. The LOD approach ruled out 453 patients (16%) with a sensitivity of 100% (95% confidence interval [CI], 99.2%-100%), the single cutoff 1516 patients (54%) with a sensitivity of 97.1% (95% CI, 95.1%-98.3%), the 1-hour algorithm 1459 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%-99.2%), and the 0/1-hour algorithm 1463 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%-99.2%). Predefined subgroup analysis in early presenters (≤2 hours) revealed significantly lower sensitivity (94.2%, interaction P=0.03) of the single cutoff, but not the other strategies. Two-year survival was 100% with LOD and 98.1% with the other strategies (P<0.01 for LOD versus each of the other strategies). CONCLUSIONS: All 4 rule-out strategies balance effectiveness and safety equally well. The single cutoff should not be applied in early presenters, whereas the 3 other strategies seem to perform well in this challenging subgroup. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00470587.
- MeSH
- akutní koronární syndrom krev diagnóza mortalita MeSH
- algoritmy MeSH
- biologické markery krev MeSH
- časové faktory MeSH
- dospělí MeSH
- elektrokardiografie MeSH
- hodnocení rizik MeSH
- infarkt myokardu krev diagnóza mortalita MeSH
- Kaplanův-Meierův odhad MeSH
- lidé středního věku MeSH
- lidé MeSH
- metody pro podporu rozhodování * MeSH
- prediktivní hodnota testů MeSH
- prognóza MeSH
- prospektivní studie MeSH
- rizikové faktory MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- sexuální faktory MeSH
- troponin I krev MeSH
- upregulace MeSH
- věkové faktory MeSH
- zdravotní stav MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- srovnávací studie MeSH
- Geografické názvy
- Evropa MeSH
BACKGROUND: The early diagnosis of acute myocardial infarction (AMI) in patients with mild elevations of high-sensitivity cardiac troponin (hs-cTn) is a challenge. It is unclear whether copeptin, a marker of endogenous stress, or 1h-hs-cTn changes are better suited to address this important unmet clinical need. METHODS: We prospectively enrolled patients presenting with symptoms suggestive of AMI to the emergency department (ED). Two independent cardiologists adjudicated the final diagnosis. Mild hs-cTn elevations were defined as 26.2 ng/L (99th percentile) to 75 ng/L for hs-cTnI, and 14 ng/L (99th percentile) to 50 ng/L (biological-equivalent to 75 ng/L for hs-cTnI) for hs-cTnT. RESULTS: Among 1356 patients, 80 (6%) had mild hs-cTnI elevations at presentation. Within this group, AMI was the final diagnosis in 39 patients (49%). The diagnostic accuracy for the diagnosis of AMI as quantified by the area under the receiver operating characteristic curve (AUC) was 0.51 (95% CI 0.39-0.64) for hs-cTnI at presentation, 0.58 (95% CI 0.45-0.71) for copeptin at presentation, and 0.78 (95% CI 0.68-0.88) for 1h-hs-cTnI changes, which was significantly higher as compared to copeptin (p = 0.02) or hs-cTnI alone (p < 0.001). The additional use of 1h-hs-cTnI changes, but not of copeptin, improved diagnostic accuracy of hs-cTnI at presentation (AUC 0.80, 95% CI 0.70-0.90; p = 0.002 for comparison). Similar findings regarding copeptin and 1h-hs-cTnT/I changes were obtained for mild hs-cTnT elevations. CONCLUSIONS: About 6-22% of patients presenting with suggestive AMI to the ED have mild hs-cTnT/I elevations at presentation. In contrast to copeptin, the addition of 1h-hs-cTn changes substantially improves the early diagnosis of AMI.
- MeSH
- biologické markery krev MeSH
- časná diagnóza MeSH
- glykopeptidy krev MeSH
- infarkt myokardu krev diagnóza MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- prospektivní studie MeSH
- ROC křivka MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- troponin I krev MeSH
- troponin T krev MeSH
- urgentní služby nemocnice MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH