AIMS: We studied the extent/area of electrical pulmonary vein isolation (PVI) after either pulsed field ablation (PFA) using a pentaspline catheter or thermal ablation technologies. METHODS AND RESULTS: In a clinical trial (NCT03714178), paroxysmal atrial fibrillation (PAF) patients underwent PVI with a multi-electrode pentaspline PFA catheter using a biphasic waveform, and after 75 days, detailed voltage maps were created during protocol-specified remapping studies. Comparative voltage mapping data were retrospectively collected from consecutive PAF patients who (i) underwent PVI using thermal energy, (ii) underwent reablation for recurrence, and (iii) had durably isolated PVs. The left and right PV antral isolation areas and non-ablated posterior wall were quantified. There were 20 patients with durable PVI in the PFA cohort, and 39 in the thermal ablation cohort [29 radiofrequency ablation (RFA), 6 cryoballoon, and 4 visually guided laser balloon]. Pulsed field ablation patients were younger with shorter follow-up. Left atrial diameter and ventricular systolic function were preserved in both cohorts. There was no significant difference between the PFA and thermal ablation cohorts in either the left- and right-sided PV isolation areas, or the non-ablated posterior wall area. The right superior PV isolation area was smaller with PFA than RFA, but this disappeared after propensity score matching. Notch-like normal voltage areas were seen at the posterior aspect of the carina in the balloon sub-cohort, but not the PFA or RFA cohorts. CONCLUSION: Catheter-based PVI with the pentaspline PFA catheter creates chronic PV antral isolation areas as encompassing as thermal energy ablation.
- MeSH
- fibrilace síní * diagnóza chirurgie MeSH
- katetrizační ablace * metody MeSH
- kryochirurgie MeSH
- laserová terapie MeSH
- lidé MeSH
- radiofrekvenční ablace MeSH
- recidiva MeSH
- retrospektivní studie MeSH
- venae pulmonales * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
BACKGROUND: Pulmonary vein (PV) stenosis is an important potential complication of PV isolation using thermal modalities such as radiofrequency ablation (RFA). Pulsed field ablation (PFA) is an alternative energy that causes nonthermal myocardial cell death. OBJECTIVE: The purpose of this study was to compare the effect of PFA vs RFA on the incidence and severity of PV narrowing or stenosis. METHODS: Data were analyzed from 4 paroxysmal atrial fibrillation ablation trials using either PFA or RFA; because of absent CT scans or poor computed tomography scan quality, 73 of 153 patients (47.7%) were excluded. Baseline and 3-month cardiac computed tomography scans were reconstructed into 3-dimensional images, and the long and short axes of the PV ostia were quantitatively and qualitatively assessed in a randomized blinded manner by 2 physicians. RESULTS: A total of 299 PVs from 80 patients after either PFA (n = 37) or RFA (n = 43) were enrolled. PV ostial diameters decreased significantly less with PFA than with RFA (% change; long axis: 0.9% ± 8.5% vs -11.9% ± 16.3%; P < .001 and short axis: 3.4% ± 12.7% vs -12.9% ± 18.5%; P < .001). After a combined quantitative/qualitative analysis, mild (30%-49%), moderate (50%-69%), or severe (70%-100%) PV narrowing was observed, respectively, in 9.0% (15 of 166), 1.8% (3 of 166), and 1.2% (2 of 166) of PVs in the RFA cohort but in none of the PVs after PFA (P < .001). Overall, PV narrowing/stenosis was present in 0% and 0% vs 12.0% and 32.5% of PVs and patients who underwent PFA and RFA, respectively. CONCLUSION: This study indicates that unlike after RFA, the incidence and severity of PV narrowing/stenosis after PV isolation is virtually eliminated with PFA.
- MeSH
- fibrilace síní diagnóza patofyziologie chirurgie MeSH
- katetrizační ablace metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- počítačová rentgenová tomografie MeSH
- převodní systém srdeční patofyziologie MeSH
- venae pulmonales chirurgie MeSH
- výsledek terapie MeSH
- zobrazování trojrozměrné metody MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Transcatheter left atrial appendage closure is an alternative therapy for stroke prevention in atrial fibrillation patients. These procedures are currently guided with transesophageal echocardiography and fluoroscopy in most centers. As intracardiac echocardiography (ICE) is commonly used in other catheter-based procedures, we sought to determine the safety and effectiveness of intracardiac echocardiography-guided left atrial appendage closure with the Watchman device. METHODS AND RESULTS: A total of 27 patients (11 males, 77.0±8.5 years) with atrial fibrillation receiving Watchman left atrial appendage closure under intracardiac echocardiography guidance at a single center were investigated. All patients were implanted successfully. There were no major procedural complications. The overall procedure-related complication rate was 14.8%, mainly due to access site hematoma. Transesophageal echocardiography demonstrated successful closure of the left atrial appendage in all patients at 45 days after device implant. CONCLUSIONS: Transcatheter left atrial appendage closure with intracardiac echocardiography guidance is safe and feasible.
- MeSH
- cévní mozková příhoda etiologie prevence a kontrola MeSH
- chirurgie s pomocí počítače metody MeSH
- echokardiografie transezofageální metody MeSH
- echokardiografie metody MeSH
- endovaskulární výkony MeSH
- fibrilace síní komplikace chirurgie MeSH
- kardiologické zobrazovací techniky metody MeSH
- lidé MeSH
- peroperační péče MeSH
- protézy a implantáty * MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- síňové ouško diagnostické zobrazování chirurgie MeSH
- srdeční katetrizace MeSH
- studie proveditelnosti MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH