A new instrumental approach to recycling HPLC is described. The concept is based on fast reintroduction of incremental peak sections back onto the separation column. The re-circulation is performed within a closed loop containing only the column and two synchronized switching valves. By having HPLC pump out of the cycle, the method minimizes peak broadening due to dead volume. As a result the efficiency is dramatically increased allowing for the most demanding analytical applications. In addition, a parking loop is employed for temporary storage of analytes from the middle section of the separated mixture prior to their recycling.
Cieľ štúdie: Ultrasonografia pľúc (LUS) je modernou alternatívnou metódou zobrazenia pľúc, ktorú môžeme využiť nielen na diferenciálnu diagnostiku príčiny respiračného zlyhania, ale aj na dynamické posúdenie respiračných funkcií. Naším cieľom bolo zhodnotiť možnosti využitia LUS pri diagnostike etiológie respiračnej insuficiencie kriticky chorých detí, zistiť rozdiel medzi LUS u ventilovaných a neventilovaných pacientov, analyzovať časové faktory jednotlivých vyšetrení, porovnať pomocou interobservačnej analýzy diagnostické výsledky auskultácie, röntgenu (RTG) a LUS a stanoviť senzitivitu a špecificitu pre vybrané respiračné ochorenia. Typ štúdie: Prospektívna klinická štúdia. Typ pracoviska: Detské anesteziologicko-resuscitačné oddelenie univerzitnej nemocnice. Materiál a metóda: Do štúdie bolo zaradených 135 detí, skupinu I tvorilo 45 kriticky chorých detí s respiračnou insuficienciou, do kontrolnej skupiny II bolo zaradených 90 detí bez diagnostikovanej respiračnej patológie. Zaznamenané boli časy a stanovené diagnózy porovnávaných vyšetrovacích metód – auskultácie, röntgenu a ultrasonografie pľúc. Výsledky: V kontrolnej skupine sme zaznamenali „fyziologické“ B-línie približne u 30 % detí. Nezaznamenali sme rozdiel v obraze LUS medzi ventilovanými a neventilovanými deťmi (zhoda 95%, κ – koeficient 0,9). Pri analýze času trvania jednotlivých vyšetrení sme dokázali štatistický rozdiel (p < 0,001) medzi jednotlivými metódami. Čas auskultácie a LUS priamo koreluje s prítomnosťou patologického nálezu na pľúcach a nepriamo s vekom dieťaťa. Pri interobservačnej analýze sme dokázali inferiórnu konkordanciu auskultácie a RTG pri porovnaní s LUS. V našom súbore pacientov sme stanovili senzitivitu a špecificitu LUS pre vybrané diagnózy – napr. pre pneumóniu (94,7 % a 98 %) pomocou LUS sme dosiahli najvýznamnejšie hodnoty. Záver: Ultrasonografia pľúc je spoľahlivou metódou na rýchlu diferenciálnu diagnostiku akútnej respiračnej insuficiencie. Klúčové slová: ultrasonografia pľúc – akútna respiračná insuficiencia – bedside diagnostika – pneumónia – ARDS – kontúzia pľúc – bronchiolitída – atelektáza pľúc
Objective: Lung ultrasound (LUS) is a modern alternative method for imaging the lungs that can be used in intensive care units not only for fast differential diagnosis of acute respiratory insufficiency but also for dynamic monitoring of the lungs. Our aims were: To validate the usability of LUS in healthy and critically ill children, to find out if there is a difference in the LUS image between non-ventilated and ventilated patients; to analyze time to diagnosis by lung auscultation, chest X-ray and lung ultrasound; to perform inter-observer analysis of these methods and to calculate the sensitivity and specificity of LUS for selected diseases. Design: Prospective clinical study. Setting: Paediatric intensive care unit of a university hospital. Materials and methods: Total 135 children were included in this study. Group I consisted of 45 critically ill children with respiratory insufficiency, Group II included 90 children without respiratory pathology. Times to disease diagnosis by auscultation, chest X-ray and LUS were recorded. Results: “Physiological” variants of the B-lines were detected in about 30% of children in Group II. We did not find any significant difference between artifact occurrence in ventilated and non-ventilated children (concordance 95%, κ coefficient 0.9). We determined a statistically significant difference in time to diagnosis by the different diagnostic methods (p < 0.001). Time to diagnosis by auscultation and LUS positively correlated with present lung pathology and negatively correlated with the age of the child. In inter-observer analysis of the three methods we stated inferior concordance of both auscultation and X-ray compared with LUS. We also calculated the sensitivity and specifity in selected diagnoses – i.e. pneumonia (94.7% and 98%, respectively) with the best values achieved using LUS. Conclusion: Lung ultrasound is a reliable method for differential diagnostics of acute respiratory insufficiency.
- MeSH
- akutní nemoc MeSH
- algoritmy MeSH
- časové faktory MeSH
- diferenciální diagnóza MeSH
- dítě MeSH
- klinické protokoly MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- novorozenec MeSH
- plíce * fyziologie patologie ultrasonografie MeSH
- pneumonie diagnóza MeSH
- počítačová rentgenová tomografie MeSH
- předškolní dítě MeSH
- prospektivní studie MeSH
- rentgendiagnostika hrudníku MeSH
- respirační insuficience * diagnóza patologie terapie MeSH
- senzitivita a specificita MeSH
- statistika jako téma MeSH
- Check Tag
- dítě MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- novorozenec MeSH
- předškolní dítě MeSH
- ženské pohlaví MeSH
2. dopl. vyd. 435 s. : il., tab. ; 16 cm
147 s. : il. ; 21cm
- Publikační typ
- abstrakt z konference MeSH