BACKGROUND AND IMPORTANCE: In 2018, the European Society of Cardiology (ESC) produced syncope guidelines that for the first-time incorporated Emergency Department (ED) management. However, very little is known about the characteristics and management of this patient group across Europe. OBJECTIVES: To examine the prevalence, clinical presentation, assessment, investigation (ECG and laboratory testing), management and ESC and Canadian Syncope Risk Score (CSRS) categories of adult European ED patients presenting with transient loss of consciousness (TLOC, undifferentiated or suspected syncope). DESIGN: Prospective, multicentre, observational cohort study. SETTINGS AND PARTICIPANTS: Adults (≥18 years) presenting to European EDs with TLOC, either undifferentiated or thought to be of syncopal origin. MAIN RESULTS: Between 00:01 Monday, September 12th to 23:59 Sunday 25 September 2022, 952 patients presenting to 41 EDs in 14 European countries were enrolled from 98 301 ED presentations (n = 40 sites). Mean age (SD) was 60.7 (21.7) years and 487 participants were male (51.2%). In total, 379 (39.8%) were admitted to hospital and 573 (60.2%) were discharged. 271 (28.5%) were admitted to an observation unit first with 143 (52.8%) of these being admitted from this. 717 (75.3%) participants were high-risk according to ESC guidelines (and not suitable for discharge from ED) and 235 (24.7%) were low risk. Admission rate increased with increasing ESC high-risk factors; 1 ESC high-risk factor; n = 259 (27.2%, admission rate=34.7%), 2; 189 (19.9%; 38.6%), 3; 106 (11.1%, 54.7%, 4; 62 (6.5%, 60.4%), 5; 48 (5.0%, 67.9%, 6+; 53 (5.6%, 67.9%). Furthermore, 660 (69.3%), 250 (26.3%), 34 (3.5%) and 8 (0.8%) participants had a low, medium, high, and very high CSRS respectively with respective admission rates of 31.4%, 56.0%, 76.5% and 75.0%. Admission rates (19.3-88.9%), use of an observation/decision unit (0-100%), and percentage high-risk (64.8-88.9%) varies widely between countries. CONCLUSION: This European prospective cohort study reported a 1% prevalence of syncope in the ED. 4 in 10 patients are admitted to hospital although there is wide variation between country in syncope management. Three-quarters of patients have ESC high-risk characteristics with admission percentage rising with increasing ESC high-risk factors.
- MeSH
- dospělí MeSH
- kohortové studie MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- synkopa * diagnóza epidemiologie terapie MeSH
- urgentní služby nemocnice * MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- Geografické názvy
- Kanada MeSH
BACKGROUND: Point-of-care (POC) high-sensitivity cardiac troponin assays may further accelerate the diagnosis of myocardial infarction (MI). OBJECTIVES: This study sought to assess the clinical and analytical performance of the novel high-sensitivity cardiac troponin I (hs-cTnI)-SPINCHIP POC test. METHODS: Adult patients presenting with acute chest discomfort to the emergency department were enrolled in an international, diagnostic, multicenter study. The final diagnosis was centrally adjudicated by 2 independent cardiologists using all clinical information. We compared the discriminatory performance of hs-cTnI-SPINCHIP with current established central laboratory assays and derived an assay-specific hs-cTnI-SPINCHIP 0/1-hour algorithm. Secondary analyses included sample type comparisons (whole blood, fresh/frozen plasma, and capillary finger prick) and precision analysis. RESULTS: MI was the adjudicated final diagnosis in 214 (19%) of 1,102 patients. Area under the receiver-operating characteristic curve was 0.94 (95% CI: 0.92-0.95) for hs-cTnI-SPINCHIP vs 0.94 (95% CI: 0.92-0.95) for hs-cTnI-Architect (P = 0.907) and 0.93 (95% CI: 0.91-0.95) for high-sensitivity cardiac troponin T Elecsys (P = 0.305). A cutoff <7 ng/L at presentation (if chest pain onset was >3 hours) or <7 ng/L together with a 0/1-hour delta of <4 ng/L ruled out 51% with a sensitivity and negative predictive value of 100% (95% CI: 97.7%-100%) and 100% (95% CI: 99.0%-100%), respectively. A hs-cTnI-SPINCHIP concentration ≥36 ng/L or a 0/1-hour delta ≥11 ng/L ruled in 27% with a specificity and positive predictive value of 90.9% (95% CI: 88.3%-92.9%) and 72.9% (95% CI: 66.4%-78.6%), respectively. Bootstrap internal validation confirmed excellent diagnostic performance. High agreement was observed between different sample types. CONCLUSIONS: The SPINCHIP hs-cTnI POC test has very high diagnostic accuracy. Its assay-specific 0/1-hour algorithm achieved very high sensitivity/negative predictive value and specificity/positive predictive value for rule-out/in MI. (Advantageous Predictors of Acute Coronary Syndromes Evaluation [APACE] Study [APACE]; NCT00470587).
- MeSH
- biologické markery krev MeSH
- infarkt myokardu * krev diagnóza MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- senioři MeSH
- senzitivita a specificita MeSH
- troponin I * krev MeSH
- vyšetření u lůžka MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
INTRODUCTION: Cannabis is the most common recreational drug worldwide and synthetic cannabinoid receptor agonists are currently the largest group of new psychoactive substances. The aim of this study was to compare the clinical features and outcomes of lone acute cannabis toxicity with lone acute synthetic cannabinoid receptor agonist toxicity in a large series of presentations to European emergency departments between 2013-2020. METHODS: Self-reported drug exposure, clinical, and outcome data were extracted from the European Drug Emergencies Network Plus which is a surveillance network that records data on drug-related emergency department presentations to 36 centres in 24 European countries. Cannabis exposure was considered the control in all analyses. To compare the lone cannabis and lone synthetic cannabinoid receptor agonist groups, univariate analysis using chi squared testing was used for categorical variables and non-parametric Mann-Whitney U- testing for continuous variables. Statistical significance was defined as a P value of <0.05. RESULTS: Between 2013-2020 there were 54,314 drug related presentations of which 2,657 were lone cannabis exposures and 503 lone synthetic cannabinoid receptor agonist exposures. Synthetic cannabinoid receptor agonist presentations had statistically significantly higher rates of drowsiness, coma, agitation, seizures and bradycardia at the time of presentation. Cannabis presentations were significantly more likely to have palpitations, chest pain, hypertension, tachycardia, anxiety, vomiting and headache. DISCUSSION: Emergency department presentations involving lone synthetic cannabinoid receptor agonist exposures were more likely to have neuropsychiatric features and be admitted to a psychiatric ward, and lone cannabis exposures were more likely to have cardiovascular features. Previous studies have shown variability in the acute toxicity of synthetic cannabinoid receptor agonists compared with cannabis but there is little comparative data available on lone exposures. There is limited direct comparison in the current literature between lone synthetic cannabinoid receptor agonist and lone cannabis exposure, with only two previous poison centre series and two clinical series. Whilst this study is limited by self-report being used to identify the drug(s) involved in the presentations, previous studies have demonstrated that self-report is reliable in emergency department presentations with acute drug toxicity. CONCLUSION: This study directly compares presentations with acute drug toxicity related to the lone use of cannabis or synthetic cannabinoid receptor agonists. It supports previous findings of increased neuropsychiatric toxicity from synthetic cannabinoid receptor agonists compared to cannabis and provides further data on cardiovascular toxicity in lone cannabis use.
- MeSH
- agonisté kanabinoidních receptorů * toxicita MeSH
- Cannabis toxicita MeSH
- dospělí MeSH
- kanabinoidy toxicita MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- retrospektivní studie MeSH
- urgentní služby nemocnice * MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
- Geografické názvy
- Evropa MeSH
BACKGROUND: We aimed to assess the diagnostic utility of the Dimension EXL LOCI High-Sensitivity Troponin I (hs-cTnI-EXL) assay. METHODS: This multicenter study included patients with chest discomfort presenting to the emergency department. Diagnoses were centrally and independently adjudicated by two cardiologists using all available clinical information. Adjudication was performed twice including serial measurements of high-sensitivity cardiac troponin (hs-cTn) I-Architect (primary analysis) and serial measurements of hs-cTnT-Elecsys (secondary analysis) in addition to the clinically used (hs)-cTn. The primary objective was to assess and compare the discriminatory performance of hs-cTnI-EXL, hs-cTnI-Architect and hs-cTnT-Elecsys for acute myocardial infarction (MI). Furthermore, we derived and validated a hs-cTnI-EXL-specific 0/1h-algorithm. RESULTS: Adjudicated MI was the diagnosis in 204/1454 (14%) patients. The area under the receiver operating characteristics curve for hs-cTnI-EXL was 0.94 (95%CI, 0.93-0.96), and comparable to hs-cTnI-Architect (0.95; 95%CI, 0.93-0.96) and hs-cTnT-Elecsys (0.93; 95%CI, 0.91-0.95). In the derivation cohort (n = 813), optimal criteria for rule-out of MI were <9ng/L at presentation (if chest pain onset >3h) or <9ng/L and 0h-1h-change <5ng/L, and for rule-in ≥160ng/L at presentation or 0h-1h-change ≥100ng/L. In the validation cohort (n = 345), these cut-offs ruled-out 56% of patients (negative predictive value 99.5% (95%CI, 97.1-99.9), sensitivity 97.8% (95%CI, 88.7-99.6)), and ruled-in 9% (positive predictive value 83.3% (95%CI, 66.4-92.7), specificity 98.3% (95%CI, 96.1-99.3)). Secondary analyses using adjudication based on hs-cTnT measurements confirmed the findings. CONCLUSIONS: The overall performance of the hs-cTnI-EXL was comparable to best-validated hs-cTnT/I assays and an assay-specific 0/1h-algorithm safely rules out and accurately rules in acute MI. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov number, NCT00470587.
- MeSH
- biologické markery MeSH
- infarkt myokardu * diagnóza MeSH
- lidé MeSH
- prospektivní studie MeSH
- ROC křivka MeSH
- troponin I * MeSH
- troponin T MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
AIMS: The presence of accompanying dyspnoea is routinely assessed and common in patients presenting with acute chest pain/discomfort to the emergency department (ED). We aimed to assess the association of accompanying dyspnoea with differential diagnoses, diagnostic work-up, and outcome. METHODS AND RESULTS: We enrolled patients presenting to the ED with chest pain/discomfort. Final diagnoses were adjudicated by independent cardiologists using all information including cardiac imaging. The primary diagnostic endpoint was the final diagnosis. The secondary diagnostic endpoint was the performance of high-sensitivity cardiac troponin (hs-cTn) and the European Society of Cardiology (ESC) 0/1h-algorithms for the diagnosis of myocardial infarction (MI). The prognostic endpoints were cardiovascular and all-cause mortality at two years. Among 6045 patients, 2892/6045 (48%) had accompanying dyspnoea. The prevalence of acute coronary syndrome (ACS) in patients with vs. without dyspnoea was comparable (MI 22.4% vs. 21.9%, P = 0.60, unstable angina 8.7% vs. 7.9%, P = 0.29). In contrast, patients with dyspnoea more often had cardiac, non-coronary disease (15.3% vs. 10.2%, P < 0.001). Diagnostic accuracy of hs-cTnT/I concentrations was not affected by the presence of dyspnoea (area under the curve 0.89-0.91 in both groups), and the safety of the ESC 0/1h-algorithms was maintained with negative predictive values >99.4%. Accompanying dyspnoea was an independent predictor for cardiovascular and all-cause death at two years [hazard ratio 1.813 (95% confidence intervals, 1.453-2.261, P < 0.01)]. CONCLUSION: Accompanying dyspnoea was not associated with a higher prevalence of ACS but with cardiac, non-coronary disease. While the safety of the diagnostic work-up was not affected, accompanying dyspnoea was an independent predictor for cardiovascular and all-cause death. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT00470587, number NCT00470587.
- MeSH
- akutní koronární syndrom * MeSH
- biologické markery MeSH
- bolesti na hrudi diagnóza etiologie MeSH
- dyspnoe diagnóza epidemiologie etiologie MeSH
- infarkt myokardu * diagnóza MeSH
- lidé MeSH
- prediktivní hodnota testů MeSH
- prognóza MeSH
- troponin T MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
INTRODUCTION AND OBJECTIVES: Release kinetics of high-sensitivity cardiac troponin (hs-cTn) T and I in patients with acute myocardial infarction (AMI) are incompletely understood. We aimed to assess whether hs-cTnT/I release in early AMI is near linear. METHODS: In a prospective diagnostic multicenter study the acute release of hs-cTnT and hs-cTnI within 1 and 2hours from presentation to the emergency department was quantified using 3 hs-cTnT/I assays in patients with suspected AMI. The primary endpoint was correlation between hs-cTn changes from presentation to 1 hour vs changes from presentation to 2hours, among all AMI patients and different prespecified subgroups. The final diagnosis was adjudicated by 2 independent cardiologists, based on serial hs-cTnT from the serial study blood samples and additional locally measured hs-cTn values. RESULTS: Among 2437 patients with complete hs-cTnT data, AMI was the adjudicated diagnosis in 376 patients (15%). For hs-cTnT, the correlation coefficient between 0- to 1-hour change and 0- to 2 hour change was 0.931 (95%CI, 0.916-0.944), P <.001. Similar findings were obtained with hs-cTnI (Architect) with correlation coefficients between 0- to 1-hour change and 0- to 2 hour change of 0.969 and hs-cTnI (Centaur) of 0.934 (P <.001 for both). Findings were consistent among type 1 and type 2 AMI and in the subgroup of patients presenting very early after chest pain onset. CONCLUSIONS: Patients presenting with early AMI showed a near linear release of hs-cTnT and hs-cTnI. This near linearity provides the pathophysiological basis for rapid diagnostic algorithms using 0- to 1-hour changes as surrogates for 0- to 2 hour or 0- to 3 hour changes. Registered at ClinicalTrials.gov (Identifier: NCT00470587).
- MeSH
- biologické markery MeSH
- infarkt myokardu * diagnóza MeSH
- kinetika MeSH
- lidé MeSH
- prospektivní studie MeSH
- troponin I MeSH
- troponin T * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
OBJECTIVE: To analyse the relative percentage of acute recreational drug toxicity emergency department (ED) presentations involving the main drug groups according to age and sex and investigate different patterns based on sex and age strata. METHODS: We analysed all patients with acute recreational drug toxicity included by the Euro-DEN Plus dataset (22 EDs in 14 European countries) between October 2013 and December 2016 (39 months). Drugs were grouped as: opioids, cocaine, cannabis, amphetamines, gamma-hydroxybutyrate (GHB), hallucinogens, new psychoactive substances (NPS), benzodiazepines and ketamine. Descriptive data by age and sex are presented and compared among age/sex categories and among drug families. RESULTS: Of 17,371 patients were included during the 39-month period, 17,198 (99.0%) had taken at least one of the investigated drugs (median age: 31 years; 23.9% female; ethanol co-ingestion recorded in 41.5%, unknown in 31.2%; multiple drug use in 37.9%). Opioids (in 31.4% of patients) and amphetamines (23.3%) were the most frequently involved and hallucinogens (1.9%) and ketamine (1.7%) the least. Overall, female patients were younger than males, both in the whole cohort (median age 29 vs. 32 years; p < 0.001) and in all drug groups except benzodiazepines (median age 36 vs. 36 years; p = 0.83). The relative proportion of each drug group was different at every age strata and some patterns could be clearly described: cannabis, NPS and hallucinogens were the most common in patients <20 years; amphetamines, ketamine and cocaine in the 20- to 39-year group; GHB/GBL in the 30- to 39-year group; and opioids and benzodiazepines in patients ≥40 years. Ethanol and other drug co-ingestion was more frequent at middle-ages, and multidrug co-ingestion was more common in females than males. CONCLUSION: Differences in the drugs involved in acute drug toxicity presentations according to age and sex may be relevant for developing drug-prevention and education programs for some particular subgroups of the population based on the increased risk of adverse events in specific sex and/or age strata.
- MeSH
- akutní nemoc MeSH
- časové faktory MeSH
- databáze faktografické MeSH
- dospělí MeSH
- hodnocení rizik MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- otrava diagnóza epidemiologie MeSH
- poruchy spojené s užíváním psychoaktivních látek diagnóza epidemiologie MeSH
- registrace MeSH
- rekreační užívání drog trendy MeSH
- rizikové faktory MeSH
- senioři MeSH
- sexuální faktory MeSH
- urgentní služby nemocnice trendy MeSH
- věkové faktory MeSH
- zakázané drogy klasifikace otrava MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- srovnávací studie MeSH
- Geografické názvy
- Evropa MeSH
AIMS: Recent data from national registries suggest that acute heart failure (AHF) outcomes might vary in men and women, however, it is not known whether this observation is universal. The aim of this study was to evaluate the association of biological sex and 1-year all-cause mortality in patients with AHF in various regions of the world. METHODS AND RESULTS: We analysed several AHF cohorts including GREAT registry (22 523 patients, mostly from Europe and Asia) and OPTIMIZE-HF (26 376 patients from the USA). Clinical characteristics and medication use at discharge were collected. Hazard ratios (HRs) for 1-year mortality according to biological sex were calculated using a Cox proportional hazards regression model with adjustment for baseline characteristics (e.g. age, comorbidities, clinical and laboratory parameters at admission, left ventricular ejection fraction). In the GREAT registry, women had a lower risk of death in the year following AHF [HR 0.86 (0.79-0.94), P < 0.001 after adjustment]. This was mostly driven by northeast Asia [n = 9135, HR 0.76 (0.67-0.87), P < 0.001], while no significant differences were seen in other countries. In the OPTIMIZE-HF registry, women also had a lower risk of 1-year death [HR 0.93 (0.89-0.97), P < 0.001]. In the GREAT registry, women were less often prescribed with a combination of angiotensin-converting enzyme inhibitors and beta-blockers at discharge (50% vs. 57%, P = 0.001). CONCLUSION: Globally women with AHF have a lower 1-year mortality and less evidenced-based treatment than men. Differences among countries need further investigation. Our findings merit consideration when designing future global clinical trials in AHF.
- MeSH
- akutní nemoc MeSH
- funkce levé komory srdeční * MeSH
- lidé MeSH
- prognóza MeSH
- prospektivní studie MeSH
- registrace MeSH
- srdeční selhání * MeSH
- tepový objem MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Asie MeSH
- Evropa MeSH
Aims: We aimed to evaluate the impact of age on the performance of the European Society of Cardiology (ESC) 0/1h-algorithms and to derive and externally validate alternative cut-offs specific to older patients. Methods and results: We prospectively enrolled patients presenting to the emergency department (ED) with symptoms suggestive of acute myocardial infarction in three large diagnostic studies. Final diagnoses were adjudicated by two independent cardiologists. High-sensitivity cardiac troponin (hs-cTn) T and I concentrations were measured at presentation and after 1 h. Patients were stratified according to age [<55 years (young), ≥55 to <70 years (middle-age), ≥70 years (old)]. Rule-out safety of the ESC hs-cTnT 0/1h-algorithm was very high in all age-strata: sensitivity 100% [95% confidence interval (95% CI) 94.9-100] in young, 99.3% (95% CI 96.0-99.9) in middle-age, and 99.3% (95% CI 97.5-99.8) in old patients. Accuracy of rule-in decreased with age: specificity 97.0% (95% CI 95.8-97.9) in young, 96.1% (95% CI 94.5-97.2) in middle-age, and 92.7% (95% CI 90.7-94.3) in older patients. Triage efficacy decreased with increasing age (young 93%, middle-age 80%, old 55%, P < 0.001). Similar results were found for the ESC hs-cTnT 0/1h-algorithm. Alternative, slightly higher cut-off concentrations optimized for older patients maintained very high safety of rule-out, increased specificity of rule-in (P < 0.01), reduced overall efficacy for hs-cTnT (P < 0.01), while maintaining efficacy for hs-cTnI. Findings were confirmed in two validation cohorts (n = 2767). Conclusion: While safety of the ESC 0/1h-algorithms remained very high, increasing age significantly reduced overall efficacy and the accuracy of rule-in. Alternative slightly higher cut-off concentrations may be considered for older patients, particularly if using hs-cTnI. Clinical Trial Registration: https://clinicaltrials.gov/ct2/show/NCT00470587, number NCT00470587 and NCT02355457 (BACC).
- MeSH
- algoritmy MeSH
- časná diagnóza MeSH
- dospělí MeSH
- infarkt myokardu diagnóza epidemiologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- senioři MeSH
- senzitivita a specificita MeSH
- směrnice pro lékařskou praxi jako téma MeSH
- troponin krev MeSH
- věkové faktory MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BACKGROUND: The European Society of Cardiology recommends a 0/1-hour algorithm for rapid rule-out and rule-in of non-ST-segment elevation myocardial infarction using high-sensitivity cardiac troponin (hs-cTn) concentrations irrespective of renal function. Because patients with renal dysfunction (RD) frequently present with increased hs-cTn concentrations even in the absence of non-ST-segment elevation myocardial infarction, concern has been raised regarding the performance of the 0/1-hour algorithm in RD. METHODS: In a prospective multicenter diagnostic study enrolling unselected patients presenting with suspected non-ST-segment elevation myocardial infarction to the emergency department, we assessed the diagnostic performance of the European Society of Cardiology 0/1-hour algorithm using hs-cTnT and hs-cTnI in patients with RD, defined as an estimated glomerular filtration rate <60 mL/min/1.73 m2, and compared it to patients with normal renal function. The final diagnosis was centrally adjudicated by 2 independent cardiologists using all available information, including cardiac imaging. Safety was quantified as sensitivity in the rule-out zone, accuracy as the specificity in the rule-in zone, and efficacy as the proportion of the overall cohort assigned to either rule-out or rule-in based on the 0- and 1-hour sample. RESULTS: Among 3254 patients, RD was present in 487 patients (15%). The prevalence of non-ST-segment elevation myocardial infarction was substantially higher in patients with RD compared with patients with normal renal function (31% versus 13%, P<0.001). Using hs-cTnT, patients with RD had comparable sensitivity of rule-out (100.0% [95% confidence interval {CI}, 97.6-100.0] versus 99.2% [95% CI, 97.6-99.8]; P=0.559), lower specificity of rule-in (88.7% [95% CI, 84.8-91.9] versus 96.5% [95% CI, 95.7-97.2]; P<0.001), and lower overall efficacy (51% versus 81%, P<0.001), mainly driven by a much lower percentage of patients eligible for rule-out (18% versus 68%, P<0.001) compared with patients with normal renal function. Using hs-cTnI, patients with RD had comparable sensitivity of rule-out (98.6% [95% CI, 95.0-99.8] versus 98.5% [95% CI, 96.5-99.5]; P=1.0), lower specificity of rule-in (84.4% [95% CI, 79.9-88.3] versus 91.7% [95% CI, 90.5-92.9]; P<0.001), and lower overall efficacy (54% versus 76%, P<0.001; proportion ruled out, 18% versus 58%, P<0.001) compared with patients with normal renal function. CONCLUSIONS: In patients with RD, the safety of the European Society of Cardiology 0/1-hour algorithm is high, but specificity of rule-in and overall efficacy are decreased. Modifications of the rule-in and rule-out thresholds did not improve the safety or overall efficacy of the 0/1-hour algorithm. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00470587.
- MeSH
- algoritmy * MeSH
- biologické markery krev MeSH
- časové faktory MeSH
- hodnocení rizik MeSH
- hodnoty glomerulární filtrace * MeSH
- infarkt myokardu bez ST elevací krev diagnóza epidemiologie MeSH
- kreatinin krev MeSH
- ledviny patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- metody pro podporu rozhodování * MeSH
- nemoci ledvin krev diagnóza epidemiologie patofyziologie MeSH
- prediktivní hodnota testů MeSH
- prevalence MeSH
- prognóza MeSH
- prospektivní studie MeSH
- reprodukovatelnost výsledků MeSH
- rizikové faktory MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- třídění pacientů * MeSH
- troponin krev MeSH
- upregulace MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Evropa MeSH