Q106983146
Dotaz
Zobrazit nápovědu
This article represents the first paper in a two-part series dealing with safety during tram-pedestrian collisions. This research is dedicated to the safety of trams for pedestrians during collisions and is motivated by the increased number of lethal cases. The first part of this paper includes an overview of tram face development from the earliest designs to the current ones in use and, at the same time, provides a synopsis and explanation of the technical context, including a link to current and forthcoming legislation. The historical design development can be characterised by three steps, from an almost vertical front face, to leaned and pointed shapes, to the current inclined low-edged windshield without a protruding coupler. However, since most major manufacturers now export their products worldwide and customisation is only of a technically insignificant nature, our conclusions are generalisable (supported by the example of Berlin). The most advantageous shape of the tram's front, minimising the effects on pedestrians in all collision phases, has evolved rather spontaneously and was unprompted, and it is now being built into the European Commission regulations. The goal of the second part of this paper is to conduct a series of tram-pedestrian collisions with a focus on the frontal and side impacts using a crash test dummy (anthropomorphic test device-ATD). Four tram types approaching the collision at four different impact speeds (5 km/h, 10 km/h, 15 km/h, and 20 km/h) were used. The primary outcome variable was the resultant head acceleration. The risk and severity of possible head injuries were assessed using the head injury criterion (HIC15) and its linkage to the injury level on the Abbreviated Injury Scale (AIS). The results showed increasing head impacts with an increasing speed for all tram types and collision scenarios. Higher values of head acceleration were reached during the frontal impact (17-124 g) compared to the side one (2-84 g). The HIC15 values did not exceed the value of 300 for any experimental setting, and the probability of AIS4+ injuries did not exceed 10%. The outcomes of tram-pedestrian collisions can be influenced by the ATD's position and orientation, the impact speed and front-end design of trams, and the site of initial contact.
- MeSH
- chodci * MeSH
- chůze MeSH
- dopravní nehody MeSH
- kraniocerebrální traumata * MeSH
- lidé MeSH
- motorová vozidla MeSH
- rány a poranění * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
This study investigated changes of gait pattern induced by a 4-week robot-assisted gait training (RAGT) in twelve ambulatory spastic diparesis children with cerebral palsy (CP) aged 10.4+/-3.2 years old by using computerized gait analysis (CGA). Pre-post intervention CGA data of children with CP was contrasted to the normative data of typically developing children by using cross-correlation and statistically evaluated by a Wilcoxon test. Significant pre-post intervention changes (p<0.01) include: decreased muscle activity of biceps femoris, rectus femoris, and tibialis anterior; a decrease in range of internal hip joint rotation, higher cadence, step length, and increased stride time. This study suggests that RAGT can be used in muscle reeducation and improved hip joint motion range in ambulatory children with CP.
- MeSH
- analýza chůze MeSH
- biomechanika MeSH
- časové faktory MeSH
- chůze (způsob) * MeSH
- dítě MeSH
- dolní končetina inervace MeSH
- lidé MeSH
- mladiství MeSH
- mozková obrna diagnóza patofyziologie rehabilitace MeSH
- obnova funkce MeSH
- předškolní dítě MeSH
- robotika přístrojové vybavení MeSH
- rozsah kloubních pohybů MeSH
- svalová síla MeSH
- techniky fyzikální terapie přístrojové vybavení MeSH
- věkové faktory MeSH
- výsledek terapie MeSH
- zatížení muskuloskeletálního systému MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- předškolní dítě MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- Geografické názvy
- Česká republika MeSH
- Slovinsko MeSH
Biofeedback je využíván k pozitivnímu ovlivnění zdravotního stavu prostřednictvím zařízení, která snímají a zobrazují průběh různých tělesných funkcí, jako jsou například tep, teplota, dechová frekvence, regionální průtok krve, mozková aktivita nebo svalové napětí. Naším cílem bylo vyhledat dostupné studie o principech, využití a účincích aplikace metod založených na principu biofeedbacku v terapii pohybového systému. Velká pozornost je věnována elektromyografickému biofeedbacku dolních i horních končetin. Časté je využití těchto metod při terapii chůze a posturálních funkcí. V těchto případech jsou použity i jiné fyzikální principy snímané informace. Jedná se o např. o tlakový biofeedback, plantografii a vibrotaktilní biofeedback. Kromě informací o účinnosti využití těchto metod byl kladen důraz na získání informací, zda je účinek okamžitý a do jaké míry přetrvává. Výhodou může být možnost využití v domácí léčbě. Z uvedeného spektra studií je možné posoudit, pro jaké diagnózy a zdravotní obtíže pacientů je vhodné jeho využití.
Biofeedback is used to positively influence the health state by means of a device, which is scanning and imaging the course of various body functions, such as pulse, temperature, respiratory rate, regional blood flow, brain activity and muscular tension. The aim of our study was to find out relevant studies about principles, use and effects of using methods based on biofeedback principle in the therapy of locomotor system. High attention was paid to electromagnetic biofeedback of upper and lower extremities. Frequent attention is using these methods in therapy of gait and postural functions. In these cases, other physical principles for scanning information are used as well. The point is for example the pressure feedback, plantography, and vibrotactile biofeedback. In addition to effectiveness of these methods the authors paid attention to obtaining information, whether the effect occurs immediately and its duration. The possibility of using this approach at home belongs to the advantages. From the described spectrum of studies is has become possible to evaluate, for which diagnoses and health complaints of the patients it is applicable.
- Klíčová slova
- elektromyografický biofeedback, tlakový biofeedback, plantografie, vibrotaktilní biofeedback,
- MeSH
- biofeedback (psychologie) metody MeSH
- elektromyografie * metody MeSH
- lidé MeSH
- rehabilitace metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- práce podpořená grantem MeSH
Cílem této práce bylo analyzovat aktivitu svalů pánevního dna prostřednictvím intravaginální perineometrie. Zaměřujeme se na nárůst způsobený fázickou svalovou činností, která krátkodobě vystupuje nad bazální aktivitu tonickou. Funkční spojitosti posturální a respirační funkce potvrzuje řada studií. Proto nás v první řadě zajímal rozdíl mezi hodnotami tlaku při klidovém spontánním dechu měřené osoby a hodnotami nárůstu tlaku při vůlí prohloubenému dechu. Potvrdili jsme při různé intenzitě dýchání ve stejné poloze (leh, stoj) statisticky významné zvýšení aktivity svalů pánevního dna při hlubokém dýchání oproti klidovému dýchání. Naše měření také ukázala, že fázická aktivita svalů pánevního dna je při hlubokém dýchání statisticky významně vyšší než ta, která byla naměřena po minutovém běhu na běhátku. Důsledky pro fyzioterapeutickou praxi a pro volbu cvičebních postupů může mít zjištěná tendence, že reakce svalů pánevního dna na spontánní nebo reflexní dýchací činnost je jiná, než na vůlív řízené dýchání. Specifickou situací je kašel, jehož krátkodobé zvýšení aktivity svalů pánevního dna převyšuje jednoznačně všechny jiné sledované situace.
The aim of this work was to analyze pelvic floor muscle activity through intravaginal perineometry. We focus on the increase due to phasic muscular activity, which short-term rises above the basal tonic activity. The functional continuity of postural and respiratory function is confirmed by a number of studies. This is the reason why we were interested first of all in the difference between the values of the pressure in the spontaneous breathing of the measured person and the pressure increased values of the voluntary deeper breath. We confirmed a statistically significant increase in pelvic floor muscle activity at deep respiration compared to resting breathing at different breathing depths at the same position (light, standing). Our measurements also showed that the phase activity of the pelvic floor muscles is statistically significantly higher in the deep breathing than the one measured after a minute running. Consequences for physiotherapeutic practice and choice of exercise procedures may have tendency to see that the response to spontaneous or reflex breathing is different than the voluntary one. A specific situation is a cough that causes a short-term increase in pelvic floor muscle activity that clearly exceeds all other observed situations.
- Klíčová slova
- perineometrie,
- MeSH
- dospělí MeSH
- dýchání MeSH
- lidé středního věku MeSH
- lidé MeSH
- pánevní dno * fyziologie MeSH
- postura těla MeSH
- výzkum MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- práce podpořená grantem MeSH
- MeSH
- dospělí MeSH
- inkontinence moči MeSH
- klinická studie jako téma MeSH
- lidé středního věku MeSH
- lidé MeSH
- manometrie využití MeSH
- muskuloskeletální systém - fyziologické jevy MeSH
- pánevní dno * fyziologie MeSH
- svalová kontrakce * MeSH
- vagina fyziologie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- ženské pohlaví MeSH
Cíl: Hlavním cílem této práce bylo zjistit, zda lze měřit 3D kinematickou analýzou tvarové změny trupu při klidovém dýchání a při použití POWERbreathe. Metodika: Výzkum byl proveden s šesti probandy přibližně stejné věkové kategorie (ženy), kdy každý z nich během měření prováděl klidové dýchání, maximální nádech, výdech, odporové dýchání za použití POWERbreathe, posléze další klidové dýchání a maximální nádech a výdech. Jako referenční hodnota bylo zvoleno klidové dýchání. Celé experimentální měření se uskutečnilo během jednoho dne. V rámci výzkumu byla použita 3D kinematická analýza pohybu pomocí systému Qualysis. Výsledky: Při stanovené prahové zátěži přístrojem POWERbreathe převažovaly pohyby směrem kraniálním v oblasti horní části trupu oproti laterálním pohybům střední a dolní části trupu.
Objective: The objective of this paper was to determine if it is possible to measure changes of trunk shape with 3D kinematic analysis during quiet breathing and when using the POWERbreathe device. Methods: The research was performed in six probands of the same age category (females). During the measurement each of them performed quiet breathing, maximum inspiration and expiration, resistance breathing using POWERbreathe device, then other quiet breath ing, maximum inspiration and expiration. Quiet breathing was chosen as a reference value. All these experimental measurements were performed in one day. 3D kinematic analysis of movement using Qualysis system was employed in the research. Results: The movements in the cranial direction in the upper part of the trunk prevailed contrary to lateral movements of the middle and inferior part of the trunk at a threshold load determined by the POWERbreathe device.