Background: Femoroacetabular impingement syndrome (FAI) is a complex, often post-traumatically developing impairment of the hip joint. It is characterized by ambiguous symptomatology, which makes early diagnosis difficult. Aim: The study was conducted to evaluate the applicability of a triaxial gyroscopic sensor in routine practice as an additional indication criterion for operative versus conservative treatment procedures. Methods: Ninety-two patients were included in the experimental retrospective study and 62 completed the examination. All patients signed informed consent. A gyroscopic sensor was placed on the right side of the pelvis above the hip joint and patients walked approximately 15 steps. Data were also evaluated while the patients climbed stairs. A complete clinical examination of the dynamics and physiological movements in the joint was performed. The data measured by the gyroscopic sensor were processed using differential geometry methods and subsequently evaluated using spectral analysis and neural networks. Results: FAI diagnosis using gyroscopic measurement is fast and easy to implement. Our approach to processing the gyroscopic signals used to detect the stage of osteoarthritis and post-traumatic FAI could lead to more accurate detection and capture early in FAI development. Conclusions: The obtained data are easily evaluated, interpretable, and beneficial in the diagnosis of the early stages of FAI. The results of the study show that this approach can lead to more accurate and early detection of osteoarthritis and post-traumatic FAI.
- MeSH
- Gait Analysis methods MeSH
- Biomechanical Phenomena * MeSH
- Femoracetabular Impingement * surgery diagnosis physiopathology MeSH
- Hip Joint physiopathology MeSH
- Humans MeSH
- Wearable Electronic Devices * MeSH
- Osteoarthritis diagnosis physiopathology MeSH
- Retrospective Studies MeSH
- Telemedicine methods MeSH
- Artificial Intelligence MeSH
- Check Tag
- Humans MeSH
This article focuses on the design and implementation of a device aimed at monitoring gait dynamics. In clinical settings, gait dynamics are conventionally observed within specialized motion laboratories that rely on camera systems or pressure-sensitive floor mats. Unfortunately, these methods provide clinicians with only a temporally restricted perspective on a patient's health within the hospital environment. The objective of this study is to propose and develop a functional prototype of a measurement device that utilizes force-sensing resistors integrated into a sensorics insole placed within a shoe. By fusion of the 3D printing technology and force-sensing sensors, we developed a wearable prototype consisting of an instrumented insole and wireless data acquisition unit. This approach enables the capture of both static and dynamic parameters of gait, not only in clinical environments but also in non-hospital settings.
Environmental screening is essential due to the increased occurrence of harmful substances in the environment. Open Meter Duo (OMD) is an open-source field photo/fluorimeter that uses an RGB diode that imitates a color according to the selected wavelength and uses a UV LED from the security kit diode as an excitation light source. The prepared PCB shield with a 3D-printed aperture was connected to Arduino UNO R4 WiFi. This system was used for the fluorescent detection of cholinesterase activity with the indoxyl acetate method. Carbofuran-a toxic pesticide-and donepezil-a drug used to treat Alzheimer's disease-were tested as model inhibitors of cholinesterase activity. The limit of detection of indoxyl acetate was 11.6 μmol/L, and the IC50 values of the inhibitors were evaluated. This system is optimized for wireless use in field analysis with added cloud support and power source. The time of analysis was 5 min for the fluorimetric assay and 20 min for the optional photometric assay. The time of field operation was approximately 4 h of continuous measurement. This system is ready to be used as a cheap and easy control platform for portable use in drug control and point-of-care testing.
- MeSH
- Alzheimer Disease * MeSH
- Cholinesterase Inhibitors therapeutic use MeSH
- Cholinesterases therapeutic use MeSH
- Donepezil therapeutic use MeSH
- Fluorometry MeSH
- Humans MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
AIMS: The management of congestion is one of the key treatment targets in heart failure. Assessing congestion is, however, difficult. The purpose of this study was to investigate the safety and dynamic response of a novel, passive, inferior vena cava (IVC) sensor in a chronic ovine model. METHODS AND RESULTS: A total of 20 sheep divided into three groups were studied in acute and chronic in vivo settings. Group I and Group II included 14 sheep in total with 12 sheep receiving the sensor and two sheep receiving a control device (IVC filter). Group III included an additional six animals for studying responses to volume challenges via infusion of blood and saline solutions. Deployment was 100% successful with all devices implanted; performing as expected with no device-related complications and signals were received at all observations. At similar volume states no significant differences in IVC area normalized to absolute area range were measured (55 ± 17% on day 0 and 62 ± 12% on day 120, p = 0.51). Chronically, the sensors were completely integrated with a thin, reendothelialized neointima with no loss of sensitivity to infused volume. Normalized IVC area changed significantly from 25 ± 17% to 43 ± 11% (p = 0.007) with 300 ml infused. In contrast, right atrial pressure required 1200 ml of infused volume prior to a statistically significant change from 3.1 ± 2.6 mmHg to 7.5 ± 2.0 mmHg (p = 0.02). CONCLUSION: In conclusion, IVC area can be measured remotely in real-time using a safe, accurate, wireless, and chronic implantable sensor promising to detect congestion with higher sensitivity than filling pressures.
- MeSH
- Sheep MeSH
- Heart Failure * therapy MeSH
- Vena Cava, Inferior * diagnostic imaging MeSH
- Animals MeSH
- Check Tag
- Animals MeSH
- Publication type
- Journal Article MeSH
INTRODUCTION: Exercise-based cardiac rehabilitation (CR) is a beneficial tool for the secondary prevention of cardiovascular diseases with, however, low participation rates. Telerehabilitation, intergrading mobile technologies and wireless sensors may advance the cardiac patients' adherence. This study will investigate the efficacy, efficiency, safety and cost-effectiveness of a telerehabilitation programme based on objective exercise telemonitoring and evaluation of cardiorespiratory fitness. METHODS AND ANALYSIS: A supervised, parallel-group, single-blind randomised controlled trial will be conducted. A total of 124 patients with coronary disease will be randomised in a 1:1 ratio into two groups: intervention telerehabilitation group (TELE-CR) (n=62) and control centre-based cardiac rehabilitation group (CB-CR) (n=62). Participants will receive a 12-week exercise-based rehabilitation programme, remotely monitored for the TELE-CR group and standard supervised for the CB-CR group. All participants will perform aerobic training at 70% of their maximal heart rate, as obtained from cardiopulmonary exercise testing (CPET) for 20 min plus 20 min for strengthening and balance training, three times per week. The primary outcomes will be the assessment of cardiorespiratory fitness, expressed as peak oxygen uptake assessed by the CPET test and the 6 min walk test. Secondary outcomes will be the physical activity, the safety of the exercise intervention (number of adverse events that may occur during the exercise), the quality of life, the training adherence, the anxiety and depression levels, the nicotine dependence and cost-effectiveness. Assessments will be held at baseline, end of intervention (12 weeks) and follow-up (36 weeks). ETHICS AND DISSEMINATION: The study protocol has been reviewed and approved by the Ethics Committee of the University of Thessaly (1108/1-12-2021) and by the Ethics Committee of the General University Hospital of Larissa (3780/31-01-2022). The results of this study will be disseminated through manuscript publications and conference presentations. TRIAL REGISTRATION NUMBER: NCT05019157.
- MeSH
- Single-Blind Method MeSH
- Cardiac Rehabilitation * methods MeSH
- Coronary Disease * rehabilitation MeSH
- Quality of Life MeSH
- Humans MeSH
- Wearable Electronic Devices * MeSH
- Randomized Controlled Trials as Topic MeSH
- Telerehabilitation * methods MeSH
- Exercise Therapy methods MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Clinical Trial Protocol MeSH
From beginning to today, pHealth has been a data driven service that collects and uses personal health information (PHI) for personal health services and personalized healthcare. As a result, pHealth services use intensively ICT technology, sensors, computers and mathematical algorithms. In past, pHealth applications were focused to certain health or sickness related problem, but in today they use mobile devices, wireless networks, Web-technology and Cloud platforms. In future, pHealth uses information systems that are highly distributed, dynamic, increasingly autonomous, multi-stakeholder data driven eco-system having ability to monitor anywhere person's regular life, movements and health related behaviours. Because privacy and trust are pre-requirements for successful pHealth, this development raises huge privacy and trust challenges to be solved. Researchers have shown that current privacy approaches and solutions used in pHealth do not offer acceptable level of privacy, and trust is only an illusion. This indicates, that today's privacy models and technology shall not be moved to the future pHealth. The authors have analysed interesting new privacy and trust ideas published in journals, and found that they seem to be effective but offer only a partial solution. To solve this weakness, the authors used a holistic system view to aspects impacting privacy and trust in pHealth, and created a template that can be used in planning and development future pHealth services. The authors also propose a tentative solution for future trustworthy pHealth. It combines privacy as personal property and trust as legal binding fiducial duty approaches, and uses a Blockchain-based smart contract solution to store person's privacy and trust requirements and service providers' promises.
We designed a simple, portable, low-cost and low-weight nondispersive infrared (NDIR) spectroscopy-based system for continuous remote sensing of atmospheric methane (CH4) with rapidly pulsed near-infrared light emitting diodes (NIR LED) at 1.65 μm. The use of a microcontroller with a field programmable gate array (μC-FPGA) enables on-the-fly and wireless streaming and processing of large data streams (~2 Gbit/s). The investigated NIR LED detection system offers favourable limits of detection (LOD) of 300 ppm (±5%) CH4,. All the generated raw data were processed automatically on-the-fly in the μC-FPGA and transferred wirelessly via a network connection. The sensing device was deployed for the portable sensing of atmospheric CH4 at a local landfill, resulting in quantified concentrations within the sampling area (ca 400 m2) in the range of 0.5%-3.35% CH4. This NIR LED-based sensor system offers a simple low-cost solution for continuous real-time, quantitative, and direct measurement of CH4 concentrations in indoor and outdoor environments, yet with the flexibility provided by the custom programmable software. It possesses future potential for remote monitoring of gases directly from mobile platforms such as smartphones and unmanned aerial vehicles (UAV).
- Publication type
- Journal Article MeSH
A non-invasive solution for monitoring of the activity and dehydration of organisms is proposed in the work. For this purpose, a wireless standalone chemical sensor platform using two separate measurement techniques has been developed. The first approach for activity monitoring is based on humidity measurement. Our solution uses new humidity sensor based on a nanostructured TiO2 surface for sweat rate monitoring. The second technique is based on monitoring of potassium concentration in urine. High level of potassium concentration denotes clear occurrence of dehydration. Furthermore, a Wireless Body Area Network (WBAN) was developed for this sensor platform to manage data transfer among devices and the internet. The WBAN coordinator controls the sensor devices and collects and stores the measured data. The collected data is particular to individuals and can be shared with physicians, emergency systems or athletes' coaches. Long-time monitoring of activity and potassium concentration in urine can help maintain the appropriate water intake of elderly people or athletes and to send warning signals in the case of near dehydration. The created sensor system was calibrated and tested in laboratory and real conditions as well. The measurement results are discussed.
- MeSH
- Wireless Technology instrumentation MeSH
- Dehydration diagnosis MeSH
- Equipment Design MeSH
- X-Ray Diffraction MeSH
- Electrodes MeSH
- Calibration MeSH
- Humans MeSH
- Monitoring, Physiologic instrumentation MeSH
- Nanostructures ultrastructure MeSH
- Computer Communication Networks instrumentation MeSH
- Titanium chemistry MeSH
- Humidity MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
Monitoring of heart rate variability (HRV) and oxygen saturation is important in medicine as well as training of top athletes. Our work describes the implementation of pulse oximetry functions in sensor system for measurement of biosignals. It allows us to follow along even pulse biosignal and the flow rate of blood.
This work is focused on problematic of biopotential signals measurements (EXG) using powerful SMART sensor system, composed of portable units, intended for in-time wireless measurement and evaluation of electrical activity, produced by skeletal muscles, human heart or brain. Here, we discuss very precise measurement features, which characterize this device (high gain, low noise, wireless data transfer, multi-probe measuring), some special features as low voltage and ultra-low power consumption were reached by application of the described amplifier in order to achieve its longer performance for daily use. It brings a lot of advantages to biomedical electronics and medical care. In order to optimize the performance of novel proposed smart biomedical instrument in our experimental part we have focused on measurement of surface electromyography (sEMG) signal to force ratio. These sEMG signals can illuminate our understanding of how the brain controls muscles to generate force and produce movement and can be used in such applications like as training of athletes, controlling robots, monitoring the physical capabilities of patients with motor disorders etc.
- MeSH
- Wireless Technology * instrumentation MeSH
- Electrodes MeSH
- Electromyography * instrumentation MeSH
- Isometric Contraction physiology MeSH
- Humans MeSH
- Signal Processing, Computer-Assisted instrumentation MeSH
- Muscle Contraction * physiology MeSH
- Muscle Strength physiology MeSH
- Muscle Fatigue physiology MeSH
- Check Tag
- Humans MeSH
- Publication type
- Research Support, Non-U.S. Gov't MeSH