AIMS: Screening logs have the potential to appraise the actual prevalence and distribution of predefined patient subsets, avoiding selection biases, which are inevitably and potentially present in randomised trials and real-world registries, respectively. We aimed to assess the prevalence of high bleeding risk (HBR) characteristics in the real world and the external validity of the MASTER DAPT trial. METHODS AND RESULTS: All consecutive patients who underwent percutaneous coronary intervention (PCI) for at least two consecutive weeks across 65 sites participating in the trial were entered into a screening log. Of 2,847 consecutive patients, 1,098 (38.6 %) were HBR and 109 (9.9 %) consented for trial participation. PRECISE-DAPT score ≥ 25 was the most frequent HBR feature, followed by advanced age, use of oral anticoagulation (OAC) and anaemia. Compared with consecutive HBR patients, consenting patients were older (≥ 75 years: 69 % versus 62 %, absolute standardized difference [SD] 0.16), more frequently male (78 % versus 71 %, absolute SD 0.18), had higher use of OAC (38 % versus 20 %, absolute SD 0.39), treatment with steroids or nonsteroidal anti-inflammatory drugs (10 % versus 5 %, SD 0.16), and prior cerebrovascular events (10 % versus 6 %, absolute SD 0.18) but lower PRECISE DAPT score ≥ 25 (54 % versus 66 %, absolute SD 0.24). CONCLUSIONS: The HBR criteria distribution differed between consecutive versus selectively included HBR patients, suggesting the existence of selection biases in the trial population.
- MeSH
- antikoagulancia škodlivé účinky terapeutické užití aplikace a dávkování MeSH
- duální protidestičková léčba škodlivé účinky metody MeSH
- hodnocení rizik MeSH
- inhibitory agregace trombocytů * škodlivé účinky terapeutické užití MeSH
- koronární angioplastika * MeSH
- krvácení * chemicky indukované epidemiologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- rizikové faktory MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- výběr pacientů MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
BACKGROUND: The optimal duration of antiplatelet therapy (APT) after coronary stenting in patients at high bleeding risk (HBR) presenting with an acute coronary syndrome remains unclear. OBJECTIVES: The objective of this study was to investigate the safety and efficacy of an abbreviated APT regimen after coronary stenting in an HBR population presenting with acute or recent myocardial infarction. METHODS: In the MASTER DAPT trial, 4,579 patients at HBR were randomized after 1 month of dual APT (DAPT) to abbreviated (DAPT stopped and 11 months single APT or 5 months in patients with oral anticoagulants) or nonabbreviated APT (DAPT for minimum 3 months) strategies. Randomization was stratified by acute or recent myocardial infarction at index procedure. Coprimary outcomes at 335 days after randomization were net adverse clinical outcomes events (NACE); major adverse cardiac and cerebral events (MACCE); and type 2, 3, or 5 Bleeding Academic Research Consortium bleeding. RESULTS: NACE and MACCE did not differ with abbreviated vs nonabbreviated APT regimens in patients with an acute or recent myocardial infarction (n = 1,780; HR: 0.83; 95% CI: 0.61-1.12 and HR: 0.86; 95% CI: 0.62-1.19, respectively) or without an acute or recent myocardial infarction (n = 2,799; HR: 1.03; 95% CI: 0.77-1.38 and HR: 1.13; 95% CI: 0.80-1.59; Pinteraction = 0.31 and 0.25, respectively). Bleeding Academic Research Consortium 2, 3, or 5 bleeding was significantly reduced in patients with or without an acute or recent myocardial infarction (HR: 0.65; 95% CI: 0.46-0.91 and HR: 0.71; 95% CI: 0.54-0.92; Pinteraction = 0.72) with abbreviated APT. CONCLUSIONS: A 1-month DAPT strategy in patients with HBR presenting with an acute or recent myocardial infarction results in similar NACE and MACCE rates and reduces bleedings compared with a nonabbreviated DAPT strategy. (Management of High Bleeding Risk Patients Post Bioresorbable Polymer Coated Stent Implantation With an Abbreviated Versus Prolonged DAPT Regimen [MASTER DAPT]; NCT03023020).
- MeSH
- antikoagulancia terapeutické užití MeSH
- dimaprit analogy a deriváty MeSH
- infarkt myokardu * farmakoterapie MeSH
- inhibitory agregace trombocytů škodlivé účinky MeSH
- kombinovaná farmakoterapie MeSH
- koronární angioplastika * metody MeSH
- krvácení chemicky indukované epidemiologie MeSH
- lidé MeSH
- polymery MeSH
- stenty MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
BACKGROUND: The COMBO drug eluting stent is a novel device with luminal endothelial progenitor cell capture technology for rapid homogeneous endothelialization. METHODS AND RESULTS: We examined for sex differences in 1-year outcomes after COMBO stenting from the COMBO collaboration, a pooled patient-level dataset from the MASCOT and REMEDEE multicenter registries. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel-myocardial infarction (TV-MI), or clinically driven target lesion revascularization (CD-TLR). Secondary outcomes included stent thrombosis (ST). Adjusted outcomes were assessed using Cox regression methods. The study included 861 (23.8%) women and 2,753 (76.2%) men. Women were older with higher prevalence of several comorbidities including diabetes mellitus. Risk of 1-year TLF was similar in both sexes (3.8% vs. 3.9%, HR 0.92, 95% CI 0.59-1.42, p = .70), without sex differences in the incidence of cardiac death (1.6% vs. 1.5%, p = .78), TV-MI (1.5% vs. 1.1%, p = .32), or CD-TLR (2.0% vs. 2.2%, p = .67). Definite or probable ST occurred in 0.4% women and 1.0% men (HR 0.26, 95% CI 0.06-1.11, p = .069). CONCLUSIONS: Despite greater clinical risks at baseline, women treated with COMBO stents had similarly low 1-year TLF and other ischemic outcomes compared to men.
- MeSH
- časové faktory MeSH
- koronární angioplastika * škodlivé účinky MeSH
- lidé MeSH
- nemoci koronárních tepen * diagnostické zobrazování chirurgie MeSH
- pohlavní dimorfismus MeSH
- protézy - design MeSH
- rizikové faktory MeSH
- stenty uvolňující léky * MeSH
- stenty MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
PURPOSE: The COMBO biodegradable polymer sirolimus-eluting stent includes endothelial progenitor cell capture (EPC) technology for rapid endothelialization, which may offer advantage in acute coronary syndromes (ACS). We sought to analyze the performance of the COMBO stent by ACS status and ACS subtype. METHODS: The COMBO collaboration (n = 3614) is a patient-level pooled dataset from the MASCOT and REMEDEE registries. We evaluated outcomes by ACS status, and ACS subtype in patients with ST segment elevation myocardial infarction (STEMI) or non-STEMI (NSTEMI) versus unstable angina (UA). The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. Secondary outcomes included stent thrombosis (ST). RESULTS: We compared 1965 (54%) ACS and 1649 (46.0%) non-ACS patients. ACS presentations included 40% (n = 789) STEMI, 31% (n = 600) NSTEMI, and 29% (n = 576) UA patients. Risk of 1-year TLF was greater in ACS patients (4.5% vs. 3.3%, HR 1.51 95% CI 1.01-2.25, p = 0.045) without significant differences in definite/probable ST (1.1% vs 0.5%, HR 2.40, 95% CI 0.91-6.31, p = 0.08). One-year TLF was similar in STEMI, NSTEMI, and UA (4.8% vs 4.8% vs. 3.7%, p = 0.60), but definite/probable ST was higher in STEMI patients (1.9% vs 0.5% vs 0.7%, p = 0.03). Adjusted outcomes were not different in MI versus UA patients. CONCLUSIONS: Despite the novel EPC capture technology, COMBO stent PCI was associated with somewhat greater risk of 1-year TLF in ACS than in non-ACS patients, without significant differences in stent thrombosis. No differences were observed in 1-year TLF among ACS subtypes.
- MeSH
- akutní koronární syndrom klasifikace komplikace mortalita chirurgie MeSH
- časové faktory MeSH
- endoteliální progenitorové buňky metabolismus MeSH
- infarkt myokardu klasifikace komplikace MeSH
- koronární angioplastika metody MeSH
- koronární trombóza epidemiologie MeSH
- lidé MeSH
- nestabilní angina pectoris komplikace MeSH
- protézy - design MeSH
- rizikové faktory MeSH
- sirolimus aplikace a dávkování MeSH
- stenty uvolňující léky škodlivé účinky statistika a číselné údaje MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Background: The COMBO stent is a biodegradable-polymer sirolimus-eluting stent with endothelial progenitor cell capture technology for faster endothelialization. Objective: We analyzed COMBO stent outcomes in relation to bleeding risk using the PARIS bleeding score. Methods: MASCOT was an international registry of all-comers undergoing attempted COMBO stent implantation. We stratified patients as low bleeding-risk (LBR) for PARIS score ≤ 3 and intermediate-to-high (IHBR) for score > 3 based on baseline age, body mass index, anemia, current smoking, chronic kidney disease and need for triple therapy. Primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, myocardial infarction (MI) not clearly attributed to a non-target vessel or clinically-driven target lesion revascularization (TLR). Bleeding was adjudicated using the Bleeding Academic Research Consortium (BARC) definition. Dual antiplatelet therapy (DAPT) cessation was independently adjudicated. Results: The study included 56% (n = 1270) LBR and 44% (n = 1009) IHBR patients. Incidence of 1-year TLF was higher in IHBR patients (4.1% vs. 2.6%, p = 0.047) driven by cardiac death (1.7% vs. 0.7%, p = 0.029) with similar rates of MI (1.8% vs. 1.1%, p = 0.17), TLR (1.5% vs. 1.6%, p = 0.89) and definite/ probable stent thrombosis (1.2% vs. 0.6%, p = 0.16). Incidence of 1-year major BARC 3 or 5 bleeding was significantly higher in IHBR patients (2.3% vs. 0.9%, p = 0.0094), as was the incidence of DAPT cessation (29.3% vs. 22.8%, p < 0.01), driven by physician-guided discontinuation. Conclusions: Patients with intermediate-to-high PARIS bleeding risk in the MASCOT registry experienced greater incidence of 1-year TLF, major bleeding and DAPT cessation than LBR patients, without significant differences in stent thrombosis.
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Small vessel diameter is associated with higher risk of target lesion revascularization (TLR) after percutaneous coronary intervention (PCI). The COMBO sirolimus-eluting biodegradable-polymer stent has a proprietary anti-CD34 antibody layer to enhance homogeneous endothelialization, which may be advantageous in treating small vessels. OBJECTIVE: We examined for differences in 1-year clinical outcomes after PCI by maximum implanted stent diameter from the COMBO collaboration. METHODS: The COMBO collaboration (n = 3614) is a patient-level pooled dataset of patients undergoing PCI with COMBO stents in the MASCOT and REMEDEE multicenter registries. Stent diameter was available in 3590 (99.3%) patients. We compared patients receiving COMBO stents <3 mm versus ≥3 mm. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel-myocardial infarction (TV-MI) or clinically driven TLR. Secondary outcomes included stent thrombosis (ST). Adjusted outcomes were assessed using Cox regression methods. RESULTS: The study included 792 (22%) patients with small stents <3 mm and 2798 (78%) patients with large stents ≥3 mm. Small stent patients included more women with lower body mass index and higher prevalence of diabetes but similar prevalence of acute coronary syndrome. Risk of 1-year TLF was similar in small and large stent groups (4.4% vs. 3.8%, HR 1.12, 95% CI 0.74-1.72, p = 0.58). There were no differences in the rates of cardiac death (1.7% vs. 1.5%, p = 0.74), TV-MI (1.4% vs. 1.2%, p = 0.58) or TLR (2.7% vs. 2.1%, p = 0.31). Definite or probable ST occurred in 1.3% of the small stent and 0.7% of the large stent PCI patients, p = 0.14, HR 2.13, 95% CI 0.93-5.00, p = 0.07. CONCLUSIONS: One-year ischemic outcomes after COMBO PCI were similar irrespective of stent diameter in this all-comers international cohort.
Older patients who undergo coronary interventions are at greater risk of ischemic events and less likely to tolerate prolonged dual antiplatelet therapy (DAPT) due to bleeding risk. The COMBO biodegradable polymer sirolimus-eluting stent promotes rapid endothelialization through endothelial progenitor cell capture technology which may be advantageous in elderly patients. We compared 1-year clinical outcomes and DAPT cessation events in patients >75 versus ≤75 years from the MASCOT registry. MASCOT was a prospective, multicenter cohort study of all-comers undergoing attempted COMBO stenting. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, myocardial infarction (MI) not clearly attributed to a nontarget vessel or clinically driven target lesion revascularization. Bleeding was adjudicated using the Bleeding Academic Research Consortium criteria. Adjusted outcomes were analyzed using Cox regression methods. The study included 18% (n = 479) patients >75 years and 72% (n = 2,135) patients ≤75 years. One-year TLF occurred in 4.6% patients >75 years versus 3.1% patients ≤75years of age, p = 0.10; adj hazard ratio 1.36, 95% confidence intervals 0.77 to 2.38, p = 0.29. There were no significant differences in cardiac death (1.7% vs 1.3%, p = 0.55), MI (2.1% vs 1.2%, p = 0.14), target lesion revascularization (1.7% vs 1.4%, p = 0.60) and definite stent thrombosis (0.8% vs 0.4%, p = 0.19). Major Bleeding Academic Research Consortium 3,5 bleeding (3.1% vs 1.5%, p = 0.01) and DAPT cessation rates (32.4% vs 23.0%, p <0.001) were significantly higher in elderly patients. In conclusion, elderly patients >75 years treated with COMBO stents had similar TLF but significantly greater incidence of bleeding than younger patients and DAPT cessation in one-third of patients over 1 year.
- MeSH
- celosvětové zdraví MeSH
- incidence MeSH
- koronární angiografie MeSH
- koronární angioplastika metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- nemoci koronárních tepen diagnóza chirurgie MeSH
- polymery * MeSH
- pooperační komplikace epidemiologie MeSH
- prospektivní studie MeSH
- protézy - design MeSH
- registrace * MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- stenty uvolňující léky * MeSH
- vstřebatelné implantáty * MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
BACKGROUND: The COMBO drug-eluting stent combines sirolimus-elution from a biodegradable polymer with an anti-CD34+ antibody coating for early endothelialization. OBJECTIVE: We investigated for geographical differences in outcomes after percutaneous coronary intervention (PCI) with the COMBO stent among Asians and Europeans. METHODS: The COMBO Collaboration is a pooled patient-level analysis of the MASCOT and REMEDEE registries of all-comers undergoing attempted COMBO stent PCI. The primary outcome was 1-year target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction (TV-MI) and target lesion revascularization (TLR). RESULTS: This study included 604 Asians (17.9%) and 2775 Europeans (82.1%). Asians were younger and included fewer females, with a higher prevalence of diabetes mellitus but lower prevalence of other comorbidities than Europeans. Asians had a higher prevalence of ACC/AHA C type lesions and received longer stent lengths. More Asians than Europeans were discharged on clopidogrel (86.5% vs 62.8%) rather than potent P2Y12 inhibitors. One-year TLF occurred in 4.0% Asians and 4.1% of Europeans, p = 0.93. The incidence of cardiac death was higher in Asians (2.8% vs. 1.3%, p = 0.007) with similar rates of TV-MI (1.5% vs. 1.2%, p = 0.54) and definite stent thrombosis (0.3% vs. 0.5%, p = 0.84) and lower incidence of TLR than Europeans (1.0% vs. 2.5%, p = 0.025). After adjustment, differences for cardiac death and TLR were no longer significant. CONCLUSIONS: In the COMBO collaboration, although 1-year TLF was similar regardless of geography, Asians experienced higher rates of cardiac death and lower TLR than Europeans, while incidence of TV-MI and ST was similar in both regions. Adjusted differences did not reach statistical significance. CLINICALTRIAL. GOV IDENTIFIER-NUMBERS: NCT01874002 (REMEDEE Registry), NCT02183454 (MASCOT registry).
- MeSH
- časové faktory MeSH
- koronární angioplastika * škodlivé účinky MeSH
- lidé MeSH
- nemoci koronárních tepen * chirurgie MeSH
- protézy - design MeSH
- rizikové faktory MeSH
- stenty uvolňující léky * MeSH
- stenty MeSH
- výsledek terapie MeSH
- zeměpis MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Asie MeSH
- Evropa MeSH
- Publikační typ
- tisková chyba MeSH
BACKGROUND: The COMBO stent (OrbusNeich Medical, Ft. Lauderdale, Florida) is a new-generation bio-engineered drug eluting stent, combining an abluminal coating of a bioabsorbable polymer matrix for sustained release of sirolimus and luminal anti-CD34 coating for endothelial progenitor cell capture and rapid endothelialization. METHODS: The Multinational Abluminal Sirolimus Coated BiO-Engineered StenT (MASCOT) registry was a prospective post-marketing study conducted from June 2014-May 2017 across 60 centers globally. Patients were eligible if COMBO stent implantation was attempted, and they received dual antiplatelet therapy (DAPT) per local guidelines. Follow-up was conducted by trained research staff at 1, 6 and 12 months by phone or clinic visit to capture clinical events and DAPT cessation events. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, non-fatal myocardial infarction not clearly attributable to a non-target vessel, or ischemia-driven target lesion revascularization. RESULTS: A total of 2614 patients were enrolled over the study period with 96.7% completion of 1-year follow-up. The mean age of enrolled patients was 62.9 ± 11.2 years and 23.0% were female. Diabetes mellitus was present at baseline in 33.5%. A total of 56.1% patients underwent PCI for acute coronary syndrome (ACS). The 1-year primary endpoint of TLF occurred in 3.4% patients (n = 88). Definite stent thrombosis occurred in 0.5% patients (n = 12). CONCLUSION: The MASCOT post marketing registry provides comprehensive safety and efficacy outcomes following contemporary PCI using the novel COMBO stent in an all-comer population. This platform is associated with low rates of 1-year TLF and ST. CLINICALTRIALS. GOV IDENTIFIER: NCT02183454.
- MeSH
- bioinženýrství metody MeSH
- časové faktory MeSH
- imunosupresiva farmakologie MeSH
- koronární angioplastika metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- nemoci koronárních tepen chirurgie MeSH
- postmarketingový dozor statistika a číselné údaje MeSH
- protézy - design MeSH
- registrace * MeSH
- retrospektivní studie MeSH
- sirolimus farmakologie MeSH
- stenty uvolňující léky * MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH