"SVV 260 548" Dotaz Zobrazit nápovědu
CE method for the baseline separation of structurally similar flavonolignans silybin A, silybin B, isosilybin A, isosilybin B, silychristin, silydianin, and their precursor taxifolin in silymarin complex has been developed and validated. The optimized background electrolyte was 100 mmol/L boric acid (pH 9.0) containing 5 mmol/L heptakis(2,3,6-tri-O-methyl)-β-CD and 10% (v/v) of methanol. The separation was carried out in an 80.5/72 cm (50 μm id) fused silica capillary at +25 kV with UV detection at 200 nm. Genistein (10 μg/mL) was used as internal standard. The resolution between the diastereomers of silybin and isosilybin was 1.73 and 2.59, respectively. The method was validated for each analyte in a concentration range of 2.5-50 μg/mL. The calibration curves were rectilinear with correlation coefficients ≥0.9972. The method was applied to determine flavonolignans in two dietary supplements containing Silybum marianum extract. The accuracy was evaluated by comparing the results of the CE analyses of the dietary supplements with those of the reference United States Pharmacopeial HPLC method. The unpaired t-test did not show a statistically significant difference between the results of both the proposed CE and the reference method (p > 0.05, n = 3).
Apples are known to be a rich source of phenolic compounds, however detailed studies about their content in the individual parts of apple trees are reported rarely. For this purpose, we tested various stationary phases for the determination of phenolic compounds in leaves, bark, and buds. Phloridzin, phloretin, chlorogenic acid, rutin, and quercitrin were analyzed with high performance liquid chromatography coupled with diode array detection. A YMC Triart C18-ExRS 150 × 4.6 mm, 5 μm particle size analytical column with multilayered particle technology was used. The separation was performed with a mobile phase that consisted of acetonitrile and 0.1% phosphoric acid, according to the gradient program, at a flow rate of 1 mL/min for 12.50 min. The concentration of phenolic compounds from 13 cultivars was in the range of 64.89-106.01 mg/g of dry weight (DW) in leaves, 70.81-113.18 mg/g DW in bark, and 100.68-139.61 mg/g DW in buds. Phloridzin was a major compound. The total antioxidant activity was measured using flow analysis and the correlation with the total amount of phenolic compounds was found. This finding can lead to the re-use of apple tree material to isolate substances that can be utilized in the food, pharmaceutical, or cosmetics industries.
- Publikační typ
- časopisecké články MeSH
A fully automated sequential injection system was tested in terms of its application in liberation testing, and capabilities and limitations were discussed for clotrimazole liberation from three semisolid formulations. An evaluation based on kinetic profiles obtained in short and longer sampling intervals and steady-state flux values were applied as traditional methods. The obtained clotrimazole liberation profile was faster in the case of Delcore and slower for Clotrimazol AL and Canesten cream commercial formulations. The steady-state flux values for the tested formulations were 52 µg cm-2 h-1 for Canesten, 35 µg cm-2 h-1 for Clotrimazol AL, and 7.2 µg cm-2 h-1 for Delcore measured in 4 min sampling intervals. A simplified approach for the evaluation of the initial rate based on the gradient between the second and third sampling points was used for the first time and was found to correspond well with the results of the conventional methods. A comparison based on the ratio of the steady-state flux and the initial rate values for Canesten and Clotrimazol AL proved the similarity of the obtained results. The proposed alternative was successfully implemented for the comparison of short-term kinetic profiles. Consequently, a faster and simpler approach for dissolution/liberation testing can be used.
We report on the hyphenation of the modern flow techniques Lab-In-Syringe and Lab-On-Valve for automated sample preparation coupled online with high-performance liquid chromatography. Adopting the bead injection concept on the Lab-On-Valve platform, the on-demand, renewable, solid-phase extraction of five nonsteroidal anti-inflammatory drugs, namely ketoprofen, naproxen, flurbiprofen, diclofenac, and ibuprofen, was carried out as a proof-of-concept. In-syringe mixing of the sample with buffer and standards allowed straightforward pre-load sample modification for the preconcentration of large sample volumes. Packing of ca. 4.4 mg microSPE columns from Oasis HLB® sorbent slurry was performed for each sample analysis using a simple microcolumn adapted to the Lab-On-Valve manifold to achieve low backpressure during loading. Eluted analytes were injected into online coupled HPLC with subsequent separation on a Symmetry C18 column in isocratic mode. The optimized method was highly reproducible, with RSD values of 3.2% to 7.6% on 20 µg L-1 level. Linearity was confirmed up to 200 µg L-1 and LOD values were between 0.06 and 1.98 µg L-1. Recovery factors between 91 and 109% were obtained in the analysis of spiked surface water samples.
The new screening method for rapid evaluation of major phenolic compounds in apples has been developed. Suitability of coupling HPLC/UHPLC separation with the diode-array detection and universal charged aerosol detection with respect to the presence of interfering substances was tested. Characteristics of both detection techniques were compared and method linearity, limits of detection and quantitation, and selectivity of them determined. Student t-test based on slopes of calibration plots was applied for the detailed comparison. The diode-array detection provided the best results regarding sensitivity and selectivity of the developed method in terms of evaluation of phenolics profiles. The response of the charged aerosol detector was negatively affected by co-eluting substances during rapid-screening analyses. Coulometric detection was used for advanced characterization of extracts in terms of antioxidant content and strength to obtain more complex information concerning sample composition. This detection also allowed evaluation of unidentified compounds with antioxidant activity. HPLC/UHPLC separation using a combination of diode-array and coulometric detectors thus represented the best approach enabling quick, yet complex characterization of bioactive compounds in apples.
- MeSH
- aerosoly chemie MeSH
- antioxidancia chemie MeSH
- chromatografie metody MeSH
- elektrochemie metody MeSH
- fenol chemie MeSH
- fenoly analýza MeSH
- kalibrace MeSH
- limita detekce MeSH
- Malus metabolismus MeSH
- potravinářská technologie MeSH
- reprodukovatelnost výsledků MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Publikační typ
- časopisecké články MeSH
According to the EU legislation, ochratoxin A contamination is controlled in wines. Tokaj wine is a special type of sweet wine produced from botrytized grapes infected by "noble rot" Botrytis cinerea. Although a high contamination was reported in sweet wines and noble rot grapes could be susceptible to coinfection with other fungi, including ochratoxigenic species, no screening of Tokaj wines for mycotoxin contamination has been carried out so far. Therefore, we developed an analytical method for the determination of ochratoxin A (OTA) and ochratoxin B (OTB) involving online SPE coupled to HPLC-FD using column switching to achieve the fast and sensitive control of mycotoxin contamination. The method was validated with recoveries ranging from 91.6% to 99.1% with an RSD less than 2%. The limits of quantification were 0.1 and 0.2 µg L-1 for OTA and OTB, respectively. The total analysis time of the online SPE-HPLC-FD method was a mere 6 min. This high throughput enables routine analysis. Finally, we carried out an extensive investigation of the ochratoxin contamination in 59 Slovak Tokaj wines of 1959-2017 vintage. Only a few positives were detected. The OTA content in most of the checked wines did not exceed the EU maximum tolerable limit of 2 µg L-1, indicating a good quality of winegrowing and storing.
- MeSH
- analýza potravin metody MeSH
- chromatografie kapalinová MeSH
- extrakce na pevné fázi MeSH
- kontaminace potravin analýza MeSH
- ochratoxiny analýza MeSH
- řízení kvality MeSH
- senzitivita a specificita MeSH
- víno analýza MeSH
- Vitis chemie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The use of stationary-phase optimized selectivity in liquid chromatography (SOS-LC) was shown to be successful for HPLC to analyze complex mixtures using a Phase OPtimized Liquid Chromatography (POPLC) kit. This commercial kit contains five stationary-phase types of varying lengths, which can be coupled to offer an improved separation of compounds. Recently, stationary-phase optimized selectivity supercritical fluid chromatography (SOS-SFC) has been introduced, transferring the methodology to SFC. In this study, the applicability of a customized POPLC expert kit for isocratic SFC runs was explored. Five stationary-phase chemistries were selected as potentially most suitable for achiral separations of polar compounds: aminopropyl (amino), cyanopropyl (CN), diol, ethylpyridine (EP), and silica. The retention factors (k) on the individual stationary phases were used for the prediction of the best stationary-phase combination, based on the POPLC algorithm (via the included software). As an alternative, the best column combination was predicted using multiple linear regression (MLR) models on the results obtained from a simplex centroid mixture design with only three stationary-phase types (amino, silica, and EP). A third approach applied the isocratic POPLC algorithm on the same three stationary-phase data. The proposed combinations were assembled and tested. The predicted and experimental retention factors were compared. The predictions based on the POPLC algorithm provided a stationary phase showing a complete separation of the mixture. The stationary phase suggested by the MLR models, on the other hand, showed co-elution of two compounds, due to an unexpected experimental retention shift. Overall, the customized POPLC kit showed good potential to be applied in SFC. Graphical abstract.
- Publikační typ
- časopisecké články MeSH