"UNCE/SCI/014"
Dotaz
Zobrazit nápovědu
The post-mortem toxicological findings may be misinterpreted, if the drug undergoes substantial post-mortem redistribution. As alprazolam is one of the most frequently evaluated drug for legal/forensic reasons in drug-related fatalities, we studied possible changes in alprazolam distribution after death in a rat model. Rats were sacrificed 30 minutes after alprazolam administration. Blood and tissue samples from 8 animals per sampling time were collected at 0, 2, 6, and 24 h after death. The experimental samples were assayed for alprazolam using validated UHPLC-PDA method. Median blood alprazolam concentrations increased approximately 2 times compared with ante-mortem levels due to the redistribution during early post-mortem phase and then slowly decreased with a half-life of 60.7 h. The highest alprazolam tissue concentrations were found in fat and liver and the lowest levels were observed in lungs and brain. The median amount of alprazolam deposited in the lungs was relatively stable over the 24-h post-mortem period, while in heart, liver and kidney the deposited proportion of administered dose increased by 43-48% in comparison with ante-mortem values indicating continuous accumulation of alprazolam into these tissues. These results provide evidence needed for the interpretation of toxicological results in alprazolam-related fatalities and demonstrate modest alprazolam post-mortem redistribution.
- MeSH
- alprazolam * farmakokinetika MeSH
- hypnotika a sedativa * farmakokinetika MeSH
- krysa rodu rattus MeSH
- posmrtné změny MeSH
- zvířata MeSH
- Check Tag
- krysa rodu rattus MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
The continuity equations that describe the movement of ions in liquid solutions under the influence of an external stationary electric field, as it is utilized in electrophoresis, were introduced a long time ago starting with Kohlrausch in 1897. From that time on, there have been many attempts to solve the equations and to discuss the results. In electrophoresis, special attention has always been devoted to the peak shapes obtained by the detector since the shapes have a tight connection with the phenomena taking place during electromigration and influence the efficiency and selectivity of the separation. Among these phenomena, the most important is electromigration dispersion. In this commented review paper, we compare various models of electromigration, try to find points that connect them, and discuss the range of their validity in light of the linear and nonlinear theory of electromigration.
The linear theory of electromigration, including the first-order nonlinear approximation, is generalized to systems with any equilibria fast enough to be considered instantaneous in comparison with the timescale of peak movement. For example, this theory is practically applied in the electrokinetic chromatography (EKC) mode of the CZE. The model enables the calculation of positions and shapes of analyte and system peaks without restricting the number of selectors, the complexation stoichiometry, or simultaneous acid-base equilibria. The latest version of our PeakMaster software, PeakMaster 6-Next Generation, implements the theory in a user-friendly way. It is a free and open-source software that performs all calculations and shows the properties of the background electrolyte and the expected electropherogram within a few seconds. In this paper, we mathematically derive the model, discuss its applicability to EKC systems, and introduce the PeakMaster 6 software.